Fast screening and quantitative mass spectral imaging of thin-layer chromatography plates with flowing atmospheric-pressure afterglow high-resolution mass spectrometry

被引:10
作者
Kuhlmann, Christopher [1 ]
Heide, Maximilian [1 ]
Engelhard, Carsten [1 ,2 ]
机构
[1] Univ Siegen, Dept Biol & Chem, Adolf Reichwein Str 2, D-57076 Siegen, Germany
[2] Univ Siegen, Ctr Micro & Nanochem & Engn, Adolf Reichwein Str 2, D-57076 Siegen, Germany
关键词
Ambient desorption/ionization; Mass spectrometry; Flowing atmospheric-pressure afterglow; Thin-layer chromatography; Quantification; CHEMICAL-IONIZATION SOURCE; ASSISTED LASER-DESORPTION; PLANAR CHROMATOGRAPHY; DESORPTION/IONIZATION; CAFFEINE; QUANTIFICATION; NICOTINE;
D O I
10.1007/s00216-019-02013-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Thin-layer chromatography (TLC) was interfaced to high-resolution mass spectrometry (MS) using a flowing atmospheric-pressure afterglow (FAPA) ambient desorption/ionization source. The influence of different TLC stationary phases on the mass spectral signal response and mass spectral image quality in FAPA-MS was carefully investigated. Specifically, a mixture of selected analgesics (acetaminophen), alkaloids (nicotine and caffeine), and steroids (cortisone) was deposited on different stationary phases (silica plates, RP-modified silica plates, CN-modified silica plates, DIOL-modified silica plates, and NH2-modified silica plates), and TLC plates with different thickness (100, 200, 250, 500, 1000, 2000 mu m) of the stationary phase. After analyte separation, mass spectral imaging was performed of the complete TLC plate via FAPA-MS and the detected ion abundance was compared. It was found that TLC plates with larger particle sizes (10-12 mu m) and thicker stationary phase layers (e.g., 1000 mu m and 2000 mu m) led to higher signals (protonated molecules) compared to smaller particles sizes (6-8 mu m) and thinner stationary phases (e.g., 100 mu m and 200 mu m). Instrumental detection limits in the low ng-range/band were determined for TLC-FAPA-MS of caffeine from RP-modified TLC silica plates. Lastly, a quantitative TLC-FAPA-MS method using stable isotope dilution analysis was developed and applied to the quantification of caffeine in energy drinks.
引用
收藏
页码:6213 / 6225
页数:13
相关论文
共 43 条
  • [1] Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds
    Andrade, Francisco J.
    Shelley, Jacob T.
    Wetzel, William C.
    Webb, Michael R.
    Gamez, Gerardo
    Ray, Steven J.
    Hieftje, Gary M.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (08) : 2654 - 2663
  • [2] Atmospheric pressure chemical ionization source. 1. Ionization of compounds in the gas phase
    Andrade, Francisco J.
    Shelley, Jacob T.
    Wetzel, William C.
    Webb, Michael R.
    Gamez, Gerardo
    Ray, Steven J.
    Hieftje, Gary M.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (08) : 2646 - 2653
  • [3] New method for caffeine quantification by planar chromatography coupled with electropray ionization mass spectrometry using stable isotope dilution analysis
    Aranda, Mario
    Morlock, Gertrud
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (07) : 1297 - 1303
  • [4] Simultaneous determination of riboflavin, pyridoxine, nicotinamide, caffeine and taurine in energy drinks by planar chromatography-multiple detection with confirmation by electrospray ionization mass spectrometry
    Aranda, Mario
    Morlock, Gertrud
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) : 253 - 260
  • [5] Chemical Aspects of the Extractive Methods of Ambient Ionization Mass Spectrometry
    Badu-Tawiah, Abraham K.
    Eberlin, Livia S.
    Ouyang, Zheng
    Cooks, R. Graham
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, VOL 64, 2013, 64 : 481 - 505
  • [6] Flowing atmospheric pressure afterglow combined with laser ablation for direct analysis of compounds separated by thin-layer chromatography
    Ceglowski, Michal
    Smoluch, Marek
    Reszke, Edward
    Silberring, Jerzy
    Schroeder, Grzegorz
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (03) : 815 - 823
  • [7] Versatile new ion source for the analysis of materials in open air under ambient conditions
    Cody, RB
    Laramée, JA
    Durst, HD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (08) : 2297 - 2302
  • [8] EPA US, 2011, DEF PROC DET METH PR, P343
  • [9] The nicotinic pharmacophore: Thermodynamics of the hydrogen-bonding complexation of nicotine, nornicotine, and models
    Graton, J
    Berthelot, M
    Gal, JF
    Laurence, C
    Lebreton, J
    Le Questel, JY
    Maria, PC
    Richard, R
    [J]. JOURNAL OF ORGANIC CHEMISTRY, 2003, 68 (21) : 8208 - 8221
  • [10] Stationary phase thickness determines the quality of thin-layer chromatography/matrix-assisted laser desorption and ionization mass spectra of lipids
    Griesinger, Hans
    Fuchs, Beate
    Suess, Rosmarie
    Matheis, Katerina
    Schulz, Michael
    Schiller, Juergen
    [J]. ANALYTICAL BIOCHEMISTRY, 2014, 451 : 45 - 47