Validation of a microtiter plate ELISA for screening of postmortem blood for opiates and benzodiazepines

被引:15
|
作者
Kemp, P
Sneed, G
Kupiec, T
Spiehler, V
机构
[1] Off Med Examiner, Oklahoma City, OK USA
[2] Analyt Res Labs Inc, Oklahoma City, OK USA
[3] Spiehler & Associates, Newport Beach, CA USA
关键词
D O I
10.1093/jat/26.7.504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for opiates and benzodiazepines for screening of postmortem blood. Ninety postmortem whole blood specimens were obtained from drug-involved deaths which had been screened and confirmed positive for opiates and/or benzodiazepines. Forty negative specimens were obtained from non-opiate-involved deaths. Specimens were tested using the Neogen Opiates Group and Neogen Benzodiazepines Group microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of opiates and benzodiazepines encountered in medical examiner specimens. True positive, true negatives, false positives, and false negatives were determined and graphed for the ELISA results against gas chromatography-mass spectrometry (GC-MS), gas chromatography-nitrogen-phosphorus detection and case histories. From these graphs and the ROC curves, the optimal cut-off for the Neogen Opiates Group ELISA was found to be between 20 and 50 ng/mL morphine equivalents and the optimum cut-off for the Neogen Benzodiazepines Group ELISA was between 20 and 50 ng/mL temazepam equivalents. The Neogen Opiates Group ELISA had a sensitivity of 95.2% ± 2.7% and a specificity of 92.2% ± 3.4% versus GC-MS at a cut-off of 20-ng/mL cut-off and a sensitivity of 88.8% ± 3.9% and specificity of 96.8% ± 2.1% versus GC-MS at a 50-ng/mL morphine equivalents cut-off. The Neogen Benzodizepines Group ELISA had a sensitivity of 100% ± 1.3% and a specificity of 94.6% ± 2.9% versus GC-MS (20-ng/mL temazepam equivalents cut-off) and a sensitivity of 95.8% ± 2.5% and specificity of 98.2% ± 1.8% versus GC-MS at a 50-ng/mL cut-off.
引用
收藏
页码:504 / 512
页数:9
相关论文
共 50 条
  • [31] NONISOTOPIC RECEPTOR ASSAY FOR BENZODIAZEPINES USING A BIOTIN-LABELED LIGAND AND BIOTIN-IMMOBILIZED MICROTITER PLATE
    TANAKA, S
    TAKEUCHI, T
    RECHNITZ, GA
    JOURNAL OF CHROMATOGRAPHY, 1992, 597 (1-2): : 443 - 448
  • [32] Comparison of ELISAs for opiates, methamphetamine, cocaine metabolite, benzodiazepines, phencyclidine, and cannabinoids in whole blood and urine
    Kerrigan, S
    Phillips, WH
    CLINICAL CHEMISTRY, 2001, 47 (03) : 540 - 547
  • [33] SCREENING, IDENTIFICATION, AND QUANTITATION OF BENZODIAZEPINES IN POSTMORTEM SAMPLES BY HPLC WITH PHOTODIODE-ARRAY DETECTION
    LAMBERT, WE
    MEYER, E
    XUEPING, Y
    DELEENHEER, AP
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (01) : 35 - 40
  • [34] A COMPUTER-PROGRAM FOR THE EVALUATION OF ELISA DATA OBTAINED USING AN AUTOMATED MICROTITER PLATE ABSORBANCE READER
    CAULFIELD, MJ
    SHAFFER, D
    JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 74 (02) : 205 - 215
  • [35] Development, evaluation, and application of a highly sensitive microtiter plate ELISA for human Bcl10 protein
    Bhattacharyya, Sumit
    Pant, Nitika
    Dudeja, Pradeep K.
    Tobacman, Joanne K.
    JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2007, 28 (03): : 173 - 188
  • [36] FLUOROMETRIC SCREENING METHOD FOR DETECTING BENZODIAZEPINES IN BLOOD AND URINE
    VALENTOUR, JC
    MONFORTE, JR
    LORENZO, B
    SUNSHINE, I
    CLINICAL CHEMISTRY, 1975, 21 (13) : 1976 - 1979
  • [37] A multichannel electrochemical detector coupled with an ELISA microtiter plate for the immunoassay of 2,4-dichlorophenoxyacetic acid
    Deng, An-Ping
    Yang, Hong
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (01) : 202 - 208
  • [38] A MICROTITER PLATE ASSAY FOR MEASUREMENT OF SERUM ALANINE AMINOTRANSFERASE IN BLOOD-DONORS
    ROZIERS, NBD
    POUILLES, F
    ROCHE, M
    CLARET, G
    TRANSFUSION, 1995, 35 (04) : 331 - 334
  • [39] THE DEVELOPMENT AND VALIDATION OF A COMPETITIVE, MICROTITER PLATE ENZYME-IMMUNOASSAY FOR HUMAN ALBUMIN IN URINE
    AKMAN, S
    KURT, I
    GULTEPE, M
    DIBIRDIK, I
    KILINC, C
    KUTLUAY, T
    KARACA, L
    BINGOL, NK
    JOURNAL OF IMMUNOASSAY, 1995, 16 (03): : 279 - 296
  • [40] Use of a microtiter plate screening method for obtaining Leuconostoc mesenteroides mutants constitutive for glucansucrase
    Kitaoka, M
    Robyt, JF
    ENZYME AND MICROBIAL TECHNOLOGY, 1998, 22 (06) : 527 - 531