Validation of a microtiter plate ELISA for screening of postmortem blood for opiates and benzodiazepines

被引:15
|
作者
Kemp, P
Sneed, G
Kupiec, T
Spiehler, V
机构
[1] Off Med Examiner, Oklahoma City, OK USA
[2] Analyt Res Labs Inc, Oklahoma City, OK USA
[3] Spiehler & Associates, Newport Beach, CA USA
关键词
D O I
10.1093/jat/26.7.504
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for opiates and benzodiazepines for screening of postmortem blood. Ninety postmortem whole blood specimens were obtained from drug-involved deaths which had been screened and confirmed positive for opiates and/or benzodiazepines. Forty negative specimens were obtained from non-opiate-involved deaths. Specimens were tested using the Neogen Opiates Group and Neogen Benzodiazepines Group microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of opiates and benzodiazepines encountered in medical examiner specimens. True positive, true negatives, false positives, and false negatives were determined and graphed for the ELISA results against gas chromatography-mass spectrometry (GC-MS), gas chromatography-nitrogen-phosphorus detection and case histories. From these graphs and the ROC curves, the optimal cut-off for the Neogen Opiates Group ELISA was found to be between 20 and 50 ng/mL morphine equivalents and the optimum cut-off for the Neogen Benzodiazepines Group ELISA was between 20 and 50 ng/mL temazepam equivalents. The Neogen Opiates Group ELISA had a sensitivity of 95.2% ± 2.7% and a specificity of 92.2% ± 3.4% versus GC-MS at a cut-off of 20-ng/mL cut-off and a sensitivity of 88.8% ± 3.9% and specificity of 96.8% ± 2.1% versus GC-MS at a 50-ng/mL morphine equivalents cut-off. The Neogen Benzodizepines Group ELISA had a sensitivity of 100% ± 1.3% and a specificity of 94.6% ± 2.9% versus GC-MS (20-ng/mL temazepam equivalents cut-off) and a sensitivity of 95.8% ± 2.5% and specificity of 98.2% ± 1.8% versus GC-MS at a 50-ng/mL cut-off.
引用
收藏
页码:504 / 512
页数:9
相关论文
共 50 条
  • [21] SIMULTANEOUS SCREENING FOR 2 DIFFERENT ANTIBODIES IN ELISA BY COMBINING 2 SOLID-PHASES - MICROTITER PLATE AND FALCON ASSAY SCREENING-TEST SYSTEM LID
    IANCONESCU, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 1985, 76 (02) : 307 - 316
  • [22] A new ELISA plate based microtiter well assay for mycobacterial topoisomerase I for the direct screening of enzyme inhibitory monoclonal antibody supernatants
    Leelaram, Majety Naga
    Suneetha, Nunna
    Nagaraja, Valakunja
    Manjunath, Ramanathapuram
    JOURNAL OF IMMUNOLOGICAL METHODS, 2010, 357 (1-2) : 26 - 32
  • [23] A microtiter plate assay for screening antioxidant activity in extracts of marine organisms
    Dunlap, W
    Llewellyn, L
    Doyle, J
    Yamamoto, Y
    MARINE BIOTECHNOLOGY, 2003, 5 (03) : 294 - 301
  • [24] A Microtiter Plate Assay for Screening Antioxidant Activity in Extracts of Marine Organisms
    Walter Dunlap
    Lyndon Llewellyn
    Jason Doyle
    Yorihiro Yamamoto
    Marine Biotechnology, 2003, 5 : 294 - 301
  • [25] Postmortem screening of opioids, benzodiazepines, and alcohol among rural and urban suicide decedents
    Bensley, Kara Marie Kubiak
    Kerr, William C.
    Barnett, Sarah Beth
    Mulia, Nina
    JOURNAL OF RURAL HEALTH, 2022, 38 (01): : 77 - 86
  • [26] The Validation of ELISA Screening According to SWGTOX Recommendations
    Tiscione, Nicholas B.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2018, 42 (03) : E33 - E34
  • [27] Evaluation of microtiter plate as a high-throughput screening platform for beer fermentation
    Zhao, Xiangdong
    Kerpes, Roland
    Becker, Thomas
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2022, 248 (07) : 1831 - 1846
  • [28] Evaluation of microtiter plate as a high-throughput screening platform for beer fermentation
    Xiangdong Zhao
    Roland Kerpes
    Thomas Becker
    European Food Research and Technology, 2022, 248 : 1831 - 1846
  • [29] A continuous microtiter plate assay for screening nucleotide sugar-synthesizing nucleotidyltransferases
    Ritter, JE
    Berlin, C
    Elling, L
    ANALYTICAL BIOCHEMISTRY, 1996, 234 (01) : 74 - 82
  • [30] SIMULTANEOUS HPLC GRADIENT ANALYSIS OF 15 BENZODIAZEPINES AND SELECTED METABOLITES IN POSTMORTEM BLOOD
    MCINTYRE, IM
    SYRJANEN, ML
    CRUMP, K
    HOROMIDIS, S
    PEACE, AW
    DRUMMER, OH
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (04) : 202 - 207