Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients

被引:312
作者
Tayal, Vivek S.
Neulander, Matthew
Norton, H. James
Foster, Troy
Saunders, Timothy
Blaivas, Michael
机构
[1] Carolinas Med Ctr, Dept Emergency Med, Charlotte, NC 28203 USA
[2] Carolinas Med Ctr, Dept Biostat, Charlotte, NC 28203 USA
[3] Charlotte Eye Ear Nose & Throat Assoc, Charlotte, NC USA
[4] Med Coll Georgia, Dept Emergency Med, Augusta, GA 30912 USA
关键词
D O I
10.1016/j.annemergmed.2006.06.040
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: Our objective is to determine whether a bedside ultrasonographic measurement of optic nerve sheath diameter can accurately predict the computed tomographic (CT) findings of elevated intracranial pressure in adult head injury patients in the emergency department (ED). Methods: We conducted a prospective, blinded observational study on adult ED patients with suspected intracranial injury with possible elevated intracranial pressure. Exclusion criteria were age younger than 18 years or obvious ocular trauma. Using a 7.5-MHz ultrasonographic probe on the closed eyelids, a single optic nerve sheath diameter was measured 3 mm behind the globe in each eye. A mean binocular optic nerve sheath diameter greater than 5.00 mm was considered abnormal. Cranial CT findings of shift, edema, or effacement suggestive of elevated intracranial pressure were used to evaluate optic nerve sheath diameter accuracy. Results: Fifty-nine patients were enrolled in the study. Average age was 38 years, and median Glasgow Coma Scale score was 15 (interquartile 6 to 15). Eight patients with an optic nerve sheath diameter of 5.00 mm or more had CT findings that correlated with elevated intracranial pressure. The sensitivity for the ultrasonography in detecting elevated intracranial pressure was 100% (95% confidence interval [Cl] 68% to 100%) and specificity was 63% (95% Cl 50% to 76%). The sensitivity of ultrasonography for detection of any traumatic intracranial injury found by CT was 84% (95% Cl 60% to 97%) and specificity was 73% (95% CI 59% to 86%). Conclusion: Bedside ED optic nerve sheath diameter ultrasonography has potential as a sensitive screening test for elevated intracranial pressure in adult head injury.
引用
收藏
页码:508 / 514
页数:7
相关论文
共 13 条
[1]  
American College of Surgeons, 1997, HEAD TRAUM, P181
[2]  
[Anonymous], 2000, J Neurotrauma
[3]  
[Anonymous], 2000, Journal of neurotrauma, V17, P497, DOI DOI 10.1089/NEU.2000.17.497
[4]  
Biros M H, 2001, Curr Opin Crit Care, V7, P444, DOI 10.1097/00075198-200112000-00012
[5]   Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath [J].
Blaivas, M ;
Theodoro, D ;
Sierzenski, PR .
ACADEMIC EMERGENCY MEDICINE, 2003, 10 (04) :376-381
[6]  
*BRAIN TRAUM FDN, 2000, J NEUROTRAUM, V17, P597
[7]  
GALETTA S, 1989, J CLIN NEURO-OPHTHAL, V9, P79
[8]   Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests [J].
Hansen, HC ;
Helmke, K .
JOURNAL OF NEUROSURGERY, 1997, 87 (01) :34-40
[9]   Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension .2. Patient study [J].
Helmke, K ;
Hansen, HC .
PEDIATRIC RADIOLOGY, 1996, 26 (10) :706-710
[10]   Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension .1. Experimental study [J].
Helmke, K ;
Hansen, HC .
PEDIATRIC RADIOLOGY, 1996, 26 (10) :701-705