Evaluation of the effect of computed tomography scan protocols and freeform fabrication methods on bone biomodel accuracy

被引:28
作者
Fitzwater, Kathryn L. [1 ]
Marcellin-Little, Denis J. [1 ]
Harrysson, Ola L. A. [3 ]
Osborne, Jason A. [4 ,5 ]
Poindexter, E. Christine [2 ]
机构
[1] N Carolina State Univ, Dept Clin Sci, Raleigh, NC 27606 USA
[2] N Carolina State Univ, Vet Teaching Hosp, Raleigh, NC 27606 USA
[3] N Carolina State Univ, Coll Vet Med, Edward P Fitts Dept Ind & Syst Engn, Raleigh, NC 27606 USA
[4] N Carolina State Univ, Coll Engn, Raleigh, NC 27606 USA
[5] N Carolina State Univ, Dept Stat, Coll Agr & Life Sci, Raleigh, NC 27606 USA
关键词
RAPID PROTOTYPING MODELS; MAXILLOFACIAL SURGERY; CRANIOFACIAL SURGERY; ZYGOMATIC IMPLANTS; IN-VITRO; STEREOLITHOGRAPHY; CT; RECONSTRUCTION; REPLACEMENT; FRACTURES;
D O I
10.2460/ajvr.72.9.1178
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To assess the effect of computed tomography (CT) scan protocols (radiation amounts) and fabrication methods on biomodel accuracy and variability. Sample-Cadaveric femur of a Basset Hound. Procedures-Retroreconstructions (n = 158) were performed of 16 original scans and were visually inspected to select 17 scans to be used for biomodel fabrication. Biomodels of the 17 scans were made in triplicate by use of 3 freeform fabrication processes (stereolithography, fused deposition modeling, and 3-D printing) for 153 models. The biomodels and original bone were measured by use of a coordinate measurement machine. Results-Differences among fabrication methods accounted for 2% to 29% of the total observed variation in inaccuracy and differences among method-specific radiation configurations accounted for 4% to 44%. Biomodels underestimated bone length and width and femoral head diameter and overestimated cortical thickness. There was no evidence of a linear association between thresholding adjustments and biomodel accuracy. Higher measured radiation dose led to a decrease in absolute relative error for biomodel diameter and for 4 of 8 cortical thickness measurements. Conclusions and Clinical Relevance-The outside dimensions of biomodels have a clinically acceptable accuracy. The cortical thickness of biomodels may overestimate cortical thickness. Variability among biomodels was caused by model fabrication reproducibility and, to a lesser extent, by the radiation settings of the CT scan and differences among fabrication methods. (Am J Vet Res 201172:1178-1185)
引用
收藏
页码:1178 / 1185
页数:8
相关论文
共 50 条
[1]   Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation [J].
Armillotta, A. ;
Bonhoeffer, P. ;
Dubini, G. ;
Ferragina, S. ;
Migliavacca, F. ;
Sala, G. ;
Schievano, S. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H4) :407-416
[2]  
Barker T M, 1994, Australas Radiol, V38, P106, DOI 10.1111/j.1440-1673.1994.tb00146.x
[3]   Flexible tubular replicas of abdominal aortic aneurysms [J].
Berry, E ;
Marsden, A ;
Dalgarno, KW ;
Kessel, D ;
Scott, DJA .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H3) :211-214
[4]   Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889
[5]  
Bredenholler C, 2005, SOMATOM SENSATION 10, P580
[6]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[7]  
Chassagne J F, 1999, Ann Chir Plast Esthet, V44, P515
[8]   Hydroxyapatite-coated polyurethane for auricular cartilage replacement:: An in vitro study [J].
Chetty, Avashnee ;
Steynberg, Tenille ;
Moolman, Sean ;
Nilen, Roger ;
Joubert, Annie ;
Richter, Wim .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (02) :475-482
[9]   Analysis of errors in medical rapid prototyping models [J].
Choi, JY ;
Choi, JH ;
Kim, NK ;
Kim, Y ;
Lee, JK ;
Kim, MK ;
Lee, JH ;
Kim, MJ .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (01) :23-32
[10]   Zygomatic implants - Protocol for immediate occlusal loading: A preliminary report [J].
Chow, J ;
Hui, E ;
Lee, PKM ;
Li, W .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (05) :804-811