Registration accuracy in computer-assisted pelvic surgery

被引:11
作者
Docquier, P. L. [1 ]
Paul, L. [1 ]
Cartiaux, O. [1 ]
Banse, X. [1 ]
机构
[1] Univ Catholique Louvain, St Luc Univ Hosp, Dept Orthopaed Surg, B-1200 Brussels, Belgium
关键词
Registration; surface-based matching; pelvic surgery;
D O I
10.3109/10929080903024361
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: An in vitro study was performed to assess the global registration accuracy of a computer-assisted system in pelvic orthopaedic surgery. The system was applied to a putative tumor resection in a pelvic sawbone. Methods: Twenty landmarks were created on the surface of the pelvis, and a virtual model of the sawbone was constructed based on surface extraction from computed tomography. The coordinates of the landmarks were defined in the CT-scan coordinate system, and registration of the sawbone with the virtual model was achieved using a surface-based matching algorithm. The landmarks were considered as control points, and deviations between their physical locations and their locations in the virtual model were calculated, thereby quantifying the global accuracy error. Results: The location of the initialization points was unimportant. The dynamic reference base gave the best results when placed far from the working area. Accuracy was improved when the sampling area was increased, but was decreased by its excessive expansion. Conclusions: It is recommended that the DRB be located on the contralateral side of the pelvis. Extending the approach posteriorly and including the entire working area in the sampling surface area, if possible, will also help increase accuracy in computer-assisted pelvic surgery.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 11 条
[1]   Surface-based registration of CT images to physical space for image-guided surgery of the spine: A sensitivity study [J].
Herring, JL ;
Dawant, BM ;
Maurer, CR ;
Muratore, DM ;
Galloway, RL ;
Fitzpatrick, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :743-752
[2]   Accuracy analysis of pedicle screw placement in posterior scoliosis surgery - Comparison between conventional fluoroscopic and computer-assisted technique [J].
Kotani, Yoshihisa ;
Abumi, Kuniyoshi ;
Ito, Manabu ;
Takahata, Masahiko ;
Sudo, Hideki ;
Ohshima, Shigeki ;
Minami, Akio .
SPINE, 2007, 32 (14) :1543-1550
[3]  
Krettek C, 2004, INJURY S1, V35
[4]  
Langlotz F, 1998, CLIN ORTHOP RELAT R, P92
[5]   The effect of fixation and location on the stability of the markers in navigated total hip arthroplasty - A Cadaver study [J].
Mayr, E ;
de la Barrera, JLM ;
Eller, G ;
Bach, C ;
Nogler, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :168-172
[6]   No benefits with computer assistance in triple pelvic osteotomy [J].
Pakvis, D ;
van Hellemondt, G ;
Anderson, P ;
de Kleuver, M .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :265-268
[7]   Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries [J].
Rajasekaran, S. ;
Vidyadhara, S. ;
Ramesh, Perumal ;
Shetty, Ajoy P. .
SPINE, 2007, 32 (02) :E56-E64
[8]  
Sugano N, 2001, Comput Aided Surg, V6, P195, DOI 10.1002/igs.10011
[9]   Computer-assisted pelvic surgery - An in vitro study of two registration protocols [J].
van Hellemondt, G ;
de Kleuver, M ;
Kerckhaert, A ;
Anderson, P ;
Langlotz, F ;
Nolte, LP ;
Pavlov, PW .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :287-293
[10]   Computer assisted pelvic tumor resection and reconstruction with a custom-made prosthesis using an innovative adaptation and its validation [J].
Wong, Kwok-Chuen ;
Kumta, Shekhar Madhukar ;
Chiu, Kwok-Hing ;
Cheung, Kin-Wing ;
Leung, Kwok-Siu ;
Unwin, Paul ;
Wong, Martin C. M. .
COMPUTER AIDED SURGERY, 2007, 12 (04) :225-232