Value of continuous glucose monitoring for minimizing severe hypoglycemia during tight glycemic control

被引:33
作者
Steil, Garry M. [1 ]
Langer, Monica [1 ]
Jaeger, Karen [1 ]
Alexander, Jamin [1 ]
Gaies, Michael [2 ]
Agus, Michael S. D. [1 ]
机构
[1] Harvard Univ, Childrens Hosp Boston, Sch Med, Dept Surg & Med, Boston, MA 02115 USA
[2] Univ Michigan, CS Mott Childrens Hosp, Sch Med, Dept Pediat & Communicable Dis, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
continuous glucose monitoring; intensive care unit; tight glycemic control; CRITICALLY-ILL PATIENTS; INTENSIVE INSULIN THERAPY; PEDIATRIC-PATIENTS; CARDIAC-SURGERY; CARE-UNIT; ALGORITHM; PROTOCOLS; DELIVERY; ICU;
D O I
10.1097/PCC.0b013e31821926a5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Tight glycemic control can potentially reduce morbidity and mortality in the intensive care unit but increases the risk of hypoglycemia. The most effective means to avoid hypoglycemia is to obtain frequent blood glucose samples, but this increases the burden to nursing staff. The objective of this study was to assess the ability of a real-time continuous glucose monitor to reduce hypoglycemia (blood glucose <60 mg/dL [3.3 mmol/L]) during standard care or tight glycemic control effected with a proportional integral derivative insulin titration algorithm. Design: Real-time continuous glucose monitor profiles obtained from an ongoing prospective randomized trial of tight glycemic control were retrospectively analyzed to determine whether the continuous glucose measure had prevented instances of hypoglycemia. Setting: Cardiac intensive care unit. Patients: Children 3 yrs of age or younger undergoing cardiac surgery were studied. Interventions: Intravenous insulin infusion and rescue glucose guided by the real-time continuous glucose monitor and the proportional integral derivative algorithm in the tight glycemic control arm (n = 155; target glucose 80-110 mg/dL [4.4-6.1 mmol/L]) and the real-time continuous glucose monitor in the standard care arm (n = 156). Measurements and Main Results: No reduction in hypoglycemia was observed with real-time continuous glucose monitor alarms set at 60 mg/dL (3.3 mmol/L) (zero of 19 occurrences of blood glucose <60 mg/dL [3.3 mmol/L] detected); 18 of 40 subsequent incidences of hypoglycemia were detected after the alarm threshold was increased to 70 mg/dL (3.9 mmol/L). In the tight glycemic control arm, eight incidences were reduced in duration and an additional eight events were prevented with intravenous glucose. In the standard care arm, three of nine occurrences of hypoglycemia were detected with the duration reduced in all cases. On average, one to two false hypoglycemia alarms were observed in each patient. Conclusions: The real-time continuous glucose monitor in combination with proportional integral derivative control can reduce hypoglycemia during tight glycemic control. The real-time continuous glucose monitor can also reduce hypoglycemia during standard care. However, false alarms increase the overall nursing workload. (Pediatr Crit Care Med 2011; 12:643-648)
引用
收藏
页码:643 / 648
页数:6
相关论文
共 29 条
  • [1] Early blood glucose control and mortality in critically ill patients in Australia
    Bagshaw, Sean M.
    Egi, Moritoki
    George, Carol
    Bellomo, Rinaldo
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (02) : 463 - 470
  • [2] A randomised controlled trial of early insulin therapy in very low birth weight infants, NIRTURE" (neonatal insulin replacement therapy in Europe)"
    Beardsall K.
    Vanhaesebrouck S.
    Ogilvy-Stuart A.L.
    Ahluwalia J.S.
    Vanhole C.
    Palmer C.
    Midgley P.
    Thompson M.
    Cornette L.
    Weissenbruch M.
    Thio M.
    de Zegher F.
    Dunger D.
    [J]. BMC Pediatrics, 7 (1)
  • [3] Comparison of Three Protocols for Tight Glycemic Control in Cardiac Surgery Patients
    Blaha, Jan
    Kopecky, Petr
    Matias, Michal
    Hovorka, Roman
    Kunstyr, Jan
    Kotulak, Tomas
    Lips, Michal
    Rubes, David
    Stritesky, Martin
    Lindner, Jaroslav
    Semrad, Michal
    Haluzik, Martin
    [J]. DIABETES CARE, 2009, 32 (05) : 757 - 761
  • [4] Intensive insulin therapy and pentastarch resuscitation in severe sepsis
    Brunkhorst, Frank M.
    Engel, Christoph
    Bloos, Frank
    Meier-Hellmann, Andreas
    Ragaller, Max
    Weiler, Norbert
    Moerer, Onnen
    Gruendling, Matthias
    Oppert, Michael
    Grond, Stefan
    Olthoff, Derk
    Jaschinski, Ulrich
    John, Stefan
    Rossaint, Rolf
    Welte, Tobias
    Schaefer, Martin
    Kern, Peter
    Kuhnt, Evelyn
    Kiehntopf, Michael
    Hartog, Christiane
    Natanson, Charles
    Loeffler, Markus
    Reinhart, Konrad
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (02) : 125 - 139
  • [5] Attempting to maintain normoglycemia during cardiopulmonary bypass with insulin may initiate postoperative hypoglycemia
    Chaney, MA
    Nikolov, MP
    Blakeman, BP
    Bakhos, M
    [J]. ANESTHESIA AND ANALGESIA, 1999, 89 (05) : 1091 - 1095
  • [6] Continuous Glucose Monitoring in Subjects with Type 1 Diabetes: Improvement in Accuracy by Correcting for Background Current
    El Youssef, Joseph
    Castle, Jessica R.
    Engle, Julia M.
    Massoud, Ryan G.
    Ward, W. Kenneth
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (11) : 921 - 928
  • [7] Intensive versus Conventional Glucose Control in Critically Ill Patients
    Finfer, S.
    Blair, D.
    Bellomo, R.
    McArthur, C.
    Mitchell, I.
    Myburgh, J.
    Norton, R.
    Potter, J.
    Chittock, D.
    Dhingra, V.
    Foster, D.
    Cook, D.
    Dodek, P.
    Hebert, P.
    Henderson, W.
    Heyland, D.
    McDonald, E.
    Ronco, J.
    Schweitzer, L.
    Peto, R.
    Sandercock, P.
    Sprung, C.
    Young, J. D.
    Su, S.
    Heritier, S.
    Li, Q.
    Bompoint, S.
    Billot, L.
    Crampton, L.
    Darcy, F.
    Jayne, K.
    Kumarasinghe, V.
    Little, L.
    McEvoy, S.
    MacMahon, S.
    Pandey, S.
    Ryan, S.
    Shukla, R.
    Vijayan, B.
    Atherton, S.
    Bell, J.
    Hadfield, L.
    Hourigan, C.
    McArthur, C.
    Newby, L.
    Simmonds, C.
    Buhr, H.
    Eccleston, M.
    McGuinness, S.
    Parke, R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (13) : 1283 - 1297
  • [8] Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit
    Goldberg, PA
    Siegel, MD
    Sherwin, RS
    Halickman, JI
    Lee, M
    Bailey, VA
    Lee, SL
    Dziura, JD
    Inzucchi, SE
    [J]. DIABETES CARE, 2004, 27 (02) : 461 - 467
  • [9] Hypoglycemia is associated with intensive care unit mortality
    Hermanides, Jeroen
    Bosman, Robert J.
    Vriesendorp, Titia M.
    Dotsch, Ron
    Rosendaal, Frits R.
    Zandstra, Durk F.
    Hoekstra, Joost B. L.
    DeVries, J. Hans
    [J]. CRITICAL CARE MEDICINE, 2010, 38 (06) : 1430 - 1434
  • [10] Real-Time Continuous Glucose Monitoring in Critically Ill Patients A prospective randomized trial
    Holzinger, Ulrike
    Warszawska, Joanna
    Kitzberger, Reinhard
    Wewalka, Marlene
    Miehsler, Wolfgang
    Herkner, Harald
    Madl, Christian
    [J]. DIABETES CARE, 2010, 33 (03) : 467 - 472