共 6 条
Anisotropy of attenuation and backscatter in cancellous bone
被引:0
作者:
Wear, KA
[1
]
机构:
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
来源:
2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2
|
2000年
关键词:
D O I:
暂无
中图分类号:
O42 [声学];
学科分类号:
070206 ;
082403 ;
摘要:
Although bone sonometry is useful in the diagnosis of osteoporosis, the interactions between ultrasound and bone are not well understood yet. In order to investigate these processes, ultrasonic attenuation and backscatter in two orientations were measured in 43 human calcaneal specimens in vitro. In the mediolateral (ML) orientation, the ultrasound propagation direction is approximately perpendicular to the trabecular axes. In the anteroposterior (AP) orientation, a wide range of angles between the ultrasound propagation direction and trabecular axes is encountered. Average attenuation slope was 18% greater while average backscatter coefficient was 50% lower in the AP orientation compared with the ML orientation. These results support the idea that absorption is a greater component of attenuation than scattering in human calcaneal trabecular bone.
引用
收藏
页码:1325 / 1328
页数:4
相关论文