Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating

被引:122
作者
Daubs, MD [1 ]
机构
[1] Univ Nevada, Sch Med, Dept Surg, Las Vegas, NV 89106 USA
关键词
cervical; corpectomy; multilevel reconstruction; titanium mesh cage; anterior cervical plating; failure;
D O I
10.1097/01.brs.0000166526.78058.3c
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective. To evaluate the use of titanium mesh cages in the reconstruction of the cervical spine following corpectomy. Summary of Background Data. Previous studies have shown high successful fusion rates and low failure rates with this technique. Similar reconstruction techniques using anterior strut bone grafting and anterior plating have shown higher failure rates following multilevel corpectomies. Methods. A retrospective review was performed of 23 consecutive patients who underwent anterior cervical corpectomy reconstructed with a titanium mesh cage, local autograft, and fixed anterior plating. Medical records and radiographs were reviewed. Average follow-up was 28 months. Results. Seven patients (30%) had reconstruction failures. There was 1 failure (6%) in the 1-level corpectomy group and 6 (75%) in the multilevel corpectomy group. All failures occurred before 12 weeks after surgery. The remaining patients had successful fusion (70%). Conclusion. There is a high early failure rate (75%) with the use of a titanium mesh cage and fixed anterior plating for reconstruction of multilevel corpectomies. Posterior fusion and instrumentation should be considered when using this technique for multilevel reconstructions.
引用
收藏
页码:1402 / 1406
页数:5
相关论文
共 15 条
[1]   Use of cylindrical titanium mesh and locking plates in anterior cervical fusion - Technical note [J].
Das, K ;
Couldwell, WT ;
Sava, G ;
Taddonio, RF .
JOURNAL OF NEUROSURGERY, 2001, 94 (01) :174-178
[2]   The in vitro effects of instrumentation on multilevel cervical strut-graft mechanics [J].
Foley, KT ;
DiAngelo, DJ ;
Rampersaud, YR ;
Vossel, KA ;
Jansen, TH .
SPINE, 1999, 24 (22) :2366-2376
[3]   Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating [J].
Hee, HT ;
Majd, ME ;
Holt, RT ;
Whitecloud, TS ;
Pienkowski, D .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2003, 16 (01) :1-9
[4]   Stabilizing potential of anterior cervical plates in multilevel corpectomies [J].
Isomi, T ;
Panjabi, MM ;
Wang, JL ;
Vaccaro, AR ;
Garfin, SR ;
Patel, T .
SPINE, 1999, 24 (21) :2219-2223
[5]   Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical spine fusion [J].
Lim, TH ;
Kwon, H ;
Jeon, CH ;
Kim, JG ;
Sokolowski, M ;
Natarajan, R ;
An, HS ;
Andersson, GBJ .
SPINE, 2001, 26 (08) :951-956
[6]   Multilevel anterior cervical corpectomy and fibular allograft fusion for cervical myelopathy [J].
MacDonald, RL ;
Fehlings, MG ;
Tator, CH ;
Lozano, A ;
Fleming, JR ;
Gentili, F ;
Bernstein, M ;
Wallace, MC ;
Tasker, RR .
JOURNAL OF NEUROSURGERY, 1997, 86 (06) :990-997
[7]   Anterior cervical reconstruction using titanium cages with anterior plating [J].
Majd, ME ;
Vadhva, M ;
Holt, RT .
SPINE, 1999, 24 (15) :1604-1610
[8]   Cervical spinal stenosis: outcome after anterior corpectomy, allograft reconstruction, and instrumentation [J].
Mayr, MT ;
Subach, BR ;
Comey, CRH ;
Rodts, GE ;
Haid, RW .
JOURNAL OF NEUROSURGERY, 2002, 96 (01) :10-16
[9]   Cervical disc replacement - Porous Coated Motion prosthesis - A comparative biomechanical analysis showing the key role of the posterior longitudinal ligament [J].
McAfee, PC ;
Cunningham, B ;
Dmitriev, A ;
Hu, NB ;
Kim, SW ;
Cappuccino, A ;
Pimenta, L .
SPINE, 2003, 28 (20) :S176-S185
[10]   Loosening at the screw-vertebra junction in multilevel anterior cervical plate constructs [J].
Panjabi, MM ;
Isomi, T ;
Wang, JL .
SPINE, 1999, 24 (22) :2383-2388