Ti-Ions and/or Particles in Saliva Potentially Aggravate Dental Implant Corrosion

被引:14
作者
Alhamad, Mostafa [1 ,2 ]
Barao, Valentim A. R. [3 ]
Sukotjo, Cortino [1 ,4 ]
Cooper, Lyndon F. [5 ]
Mathew, Mathew T. [1 ]
机构
[1] Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL 60612 USA
[2] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, Dammam 34212, Saudi Arabia
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, BR-13414903 Piracicaba, SP, Brazil
[4] Bahcesehir Univ, Sch Dent Med, Dept Prosthodont, TR-34353 Istanbul, Turkey
[5] Univ Illinois, Coll Dent, Dept Oral Biol, Chicago, IL 60612 USA
关键词
corrosion; titanium; dental alloys; peri-implantitis; dental implant; PERI-IMPLANTITIS; TITANIUM CORROSION; RELEASE; RESISTANCE; FLUORIDE; ALLOY;
D O I
10.3390/ma14195733
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The corrosive titanium products in peri-implant tissues are a potential risk factor for peri-implantitis. There is very limited information available on the effect of the corrosion and wear products on the dental implant corrosion. Therefore, we determined the influence of Ti-ions and Ti-particles on Ti corrosion. Eighteen commercially pure-Ti-grade-2 discs were polished to mirror-shine. Samples were divided into six groups (n = 3) as a function of electrolytes; (A) Artificial saliva (AS), (B) AS with Ti-ions (the electrolyte from group A, after corrosion), (C) AS with Ti-particles 10 ppm (D) AS with Ti-particles 20 ppm, (E) AS with Ti-ions 10 ppm, and (F) AS with Ti-ions 20 ppm. Using Tafel's method, corrosion potential (E-corr) and current density (I-corr) were estimated from potentiodynamic curves. Electrochemical Impedance Spectroscopy (EIS) data were used to construct Nyquist and Bode plots, and an equivalent electrical circuit was used to assess the corrosion kinetics. The corroded surfaces were examined through a 3D-white-light microscope and scanning electronic microscopy. The data demonstrated that the concentration of Ti-ions and corrosion rate (I-corr) are strongly correlated (r = 0.997, p = 0.046). This study indicated that high Ti-ion concentration potentially aggravates corrosion. Under such a severe corrosion environment, there is a potential risk of increased implant associated adverse tissue reactions.
引用
收藏
页数:14
相关论文
共 42 条
  • [1] The effect of metal ions released from different dental implant-abutment couples on osteoblast function and secretion of bone resorbing mediators
    Alrabeah, Ghada O.
    Brett, Peter
    Knowles, Jonathan C.
    Petridis, Haralampos
    [J]. JOURNAL OF DENTISTRY, 2017, 66 : 91 - 101
  • [2] The Role of Lipopolysaccharide on the Electrochemical Behavior of Titanium
    Barao, V. A.
    Mathew, M. T.
    Assuncao, W. G.
    Yuan, J. C.
    Wimmer, M. A.
    Sukotjo, C.
    [J]. JOURNAL OF DENTAL RESEARCH, 2011, 90 (05) : 613 - 618
  • [3] Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study
    Barao, Valentim A. R.
    Mathew, Mathew T.
    Assuncao, Wirley Goncalves
    Yuan, Judy Chia-Chun
    Wimmer, Markus A.
    Sukotjo, Cortino
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (09) : 1055 - 1062
  • [4] Titanium particles: An emerging risk factor for peri-implant bone loss
    Berryman, Zoe
    Bridger, Laura
    Hussaini, Haizal Mohd
    Rich, Alison M.
    Atieh, Momen
    Tawse-Smith, Andrew
    [J]. SAUDI DENTAL JOURNAL, 2020, 32 (06) : 283 - 292
  • [5] Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces
    Bijukumar, Divya Rani
    Salunkhe, Shruti
    Zheng, Guoxing
    Barba, Mark
    Halle, Deborah J.
    Pourzal, Robin
    Mathew, Mathew T.
    [J]. ACTA BIOMATERIALIA, 2020, 101 : 586 - 597
  • [6] Clinical and microbiological findings in patients with peri-implantitis: a cross-sectional study
    Canullo, Luigi
    Penarrocha-Oltra, David
    Covani, Ugo
    Botticelli, Daniele
    Serino, Giovanni
    Penarrocha, Miguel
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (03) : 376 - 382
  • [7] Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review
    Delgado-Ruiz, Rafael
    Romanos, Georgios
    [J]. INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (11)
  • [8] Progression of Bio-Tribocorrosion in Implant Dentistry
    Dini, Caroline
    Costa, Raphael C.
    Sukotjo, Cortino
    Takoudis, Christos G.
    Mathew, Mathew T.
    Barao, Valentim A. R.
    [J]. FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2020, 6
  • [9] Trends in Dental Implant Use in the US, 1999-2016, and Projections to 2026
    Elani, H. W.
    Starr, J. R.
    Da Silva, J. D.
    Gallucci, G. O.
    [J]. JOURNAL OF DENTAL RESEARCH, 2018, 97 (13) : 1424 - 1430
  • [10] Elemek Eser, 2020, Eur J Dent, V14, P24, DOI 10.1055/s-0040-1701162