In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population

被引:14
作者
Wu, Ying [1 ]
Tian, Lei [2 ]
Huang, Yi-fei [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Ophthalmol, Beijing 100853, Peoples R China
[2] Capital Med Univ, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Hosp, Beijing Inst Ophthalmol,Beijing Tongren Eye Ctr, Beijing 100730, Peoples R China
基金
中国国家自然科学基金;
关键词
CORVIS ST; DEFORMATION RESPONSE; NONCONTACT; KERATOCONUS; PRESSURE; HEALTHY; REPEATABILITY; TOMOGRAPHY; PARAMETERS; TONOMETER;
D O I
10.1155/2016/7840284
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Purpose. To determine the repeatability of recalculated corneal visualization Scheimpflug technology (CorVis ST) parameters and to study the variation of biomechanical properties and their association with demographic and ocular characteristics. Methods. A total of 783 healthy subjects were included in this study. Comprehensive ophthalmological examinations were conducted. The repeatability of the recalculated biomechanical parameters with 90 subjects was assessed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). Univariate and multivariate linear regression models were used to identify demographic and ocular factors. Results. The repeatability of the central corneal thickness (CCT), deformation amplitude (DA), and first/second applanation time (A1/A2-time) exhibited excellent repeatability (CV% <= 3.312% and ICC >= 0.929 for all measurements). The velocity in/out (V-in/out), highest concavity- (HC-) radius, peak distance (PD), and DA showed a normal distribution. Univariate linear regression showed a statistically significant correlation between V-in, V-out, DA, PD, and HC- radius and IOP, CCT, and corneal volume, respectively. Multivariate analysis showed that IOP and CCT were negatively correlated with V-in, DA, and PD, while there was a positive correlation between V-out and HC- radius. Conclusion. The ICCs of the recalculated parameters, CCT, DA, A1-time, and A2-time, exhibited excellent repeatability. IOP, CCT, and corneal volume significantly influenced the biomechanical properties of the eye.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer [J].
Ali, Noor Q. ;
Patel, Dipika V. ;
McGhee, Charles N. J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) :3651-3659
[2]   Dynamic Scheimpflug-based Assessment of Keratoconus and the Effects of Corneal Cross-linking [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben B. ;
Ivarsen, Anders ;
Hjortdal, Jesper .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) :408-414
[3]   Biomechanical Properties of Human Corneas Following Low- and High-Intensity Collagen Cross-Linking Determined With Scanning Acoustic Microscopy [J].
Beshtawi, Ithar M. ;
Akhtar, Riaz ;
Hillarby, M. Chantal ;
O'Donnell, Clare ;
Zhao, Xuegen ;
Brahma, Arun ;
Carley, Fiona ;
Derby, Brian ;
Radhakrishnan, Hema .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) :5273-5280
[4]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[5]   Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging [J].
Correia, Fernando Faria ;
Ramos, Isaac ;
Roberts, Cynthia J. ;
Steinmueller, Andreas ;
Krug, Matthias ;
Ambrosio, Renato, Jr. .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (05) :278-281
[6]  
Daxer A, 1998, INVEST OPHTH VIS SCI, V39, P644
[7]   Biomechanical properties of human and porcine corneas [J].
Elsheikh, Ahmed ;
Alhasso, Daad ;
Rama, Paolo .
EXPERIMENTAL EYE RESEARCH, 2008, 86 (05) :783-790
[8]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[9]   Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system [J].
Emre, Sinan ;
Doganay, Selim ;
Yologlu, Saim .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10) :1708-1712
[10]   Scheimpflug-Based Tomography and Biomechanical Assessment in Pressure-Induced Stromal Keratopathy [J].
Faria-Correia, Fernando ;
Ramos, Isaac ;
Valbon, Bruno ;
Luz, Allan ;
Roberts, Cynthia J. ;
Ambrosio, Renato, Jr. .
JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (05) :356-358