Comparison of Motor Neutral Point Overvoltage Oscillations in SiC-Based Adjustable Speed Drives using Two-Level and Three-Level Inverters

被引:1
|
作者
Zhou, Wenzhi [1 ]
Diab, Mohamed [2 ]
Yuan, Xibo [1 ]
机构
[1] Univ Bristol, Dept Elect & Elect Engn, Bristol, England
[2] Loughborough Univ, Sch Mech Elect & Mfg Engn, Loughborough, England
来源
2022 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2022年
基金
英国工程与自然科学研究理事会;
关键词
Common mode voltage; high dv/dt; motor drives; neutral point overvoltage; reflected wave phenomenon; SiC MOSFET; OPPORTUNITIES; CHALLENGES; MITIGATION; FREQUENCY; IMPACT;
D O I
10.1109/ECCE50734.2022.9947904
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In SiC-based adjustable speed drives, power cables have similar behaviour to transmission lines due to the steep voltage pulses (high dv/dt) which experience back and forth voltage reflections while travelling across the cables, known as the reflected wave phenomenon, resulting in serious motor overvoltage oscillations. Besides the widely known overvoltage at the motor terminals, the motor neutral point experiences overvoltage oscillations that can be more detrimental than the terminal overvoltage. This paper investigates the motor neutral point overvoltage oscillations due to the reflected wave phenomenon in SiC-based adjustable speed drives using the two-level (2L) and three-level (3L) power inverters under the conventional PWM scheme. In fact, the overvoltage at the motor neutral point arises from the propagation of the inverter common mode (CM) voltage pulses through the motor winding itself, which emulates the same effect of long cables. The analysis and experimental results show that the motor neutral point overvoltage oscillations are characterized by the first anti-resonance point of the motor drive system, while the amplitude of the neutral point overvoltage is affected by the inverter CM voltage waveform. The results show that the motor neutral point experiences a higher overvoltage when the inverter is operated at high switching frequency and low modulation index. Moreover, when the switching frequency coincides with the first anti-resonance frequency of the motor drive system, the motor neutral point experiences the highest overvoltage. Specifically, the maximum motor neutral point voltage is 3 times the dc-link voltage for the 2L inverter. In contrast, the maximum motor neutral point voltage is 1.5 times the dc-link voltage when the 3L inverter is used.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] EMI Performance Comparison of Two-Level and Three-Level Inverters in Small Dc-Link Capacitors Based Motor Drives
    Maheshwari, RamKrishan
    Munk-Nielsen, Stig
    Busquets-Monge, Sergio
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 652 - 657
  • [2] Performance Comparison Between Two-Level and Three-Level SiC-Based VFD Applications With Output Filters
    Baek, Seunghoon
    Cho, Younghoon
    Cho, Byung-Geuk
    Hong, Chanook
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (05) : 4770 - 4779
  • [3] Performance Comparison Between Two-Level and Three-Level SiC-Based VFD Applications with Output Filters
    Baek, Seunghoon
    Cho, Younghoon
    Cho, Byung-Geuk
    Hong, Chanook
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 798 - 805
  • [4] Improved design of three-level NPC inverters in comparison to two-level inverters
    Jafari, Hengameh Kojooyan
    Radan, Ahmad
    WSEAS Transactions on Circuits and Systems, 2009, 8 (02): : 207 - 216
  • [5] Comparison between DTC using a two-level inverters and DTC using a three level inverters of Induction Motor
    Ouboubker, Lahcen
    Khafallah, Mohamed
    Lamterkati, Jawad
    Chikh, Khalid
    2014 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2014, : 1051 - 1058
  • [6] Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
    Chao, Kuei-Hsiang
    Ke, Chen-Hou
    ENERGIES, 2020, 13 (23)
  • [7] Loss Analysis of SiC-based Three-Level Active Neutral-Point-Clamped Inverters under Different Modulation Schemes
    Chen, Mengxing
    Zhu, Tianyu
    Pan, Donghua
    Wang, Huai
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 971 - 978
  • [8] Design and Implementation of a dv/dt Filter for Motor Overvoltage Mitigation in SiC-Based Adjustable Speed Drives
    Zhou, Wenzhi
    Zhang, Zhaobo
    Yuan, Xibo
    Diab, Mohamed
    2024 IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, APEC, 2024, : 1046 - 1053
  • [9] Multilevel dodecagonal space-vector generation for induction motor drives by cascading three-level and two-level inverters
    Mathew, K.
    Mathew, J.
    Azeez, N. A.
    Dey, A.
    Umanand, L.
    Gopakumar, K.
    IET POWER ELECTRONICS, 2012, 5 (08) : 1324 - 1332
  • [10] RESEARCH ON MOTOR OVERVOLTAGE ISSUES IN METALLURGICAL ENVIRONMENTS USING THREE-LEVEL INVERTERS
    Meng, L. L.