A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe

被引:75
作者
Zhang, Jing [1 ,2 ]
Chen, Pingping [1 ]
Wu, XiaoYan [1 ]
Chen, JingHua [1 ,3 ]
Xu, LiangJun [1 ]
Chen, GuoNan [1 ]
Fu, FengFu [1 ]
机构
[1] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Key Lab Anal & Detect Food Safety,Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Coll Med Occupat & Technol, Dept Pharmaceut, Fuzhou 350101, Fujian, Peoples R China
[3] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Fujian, Peoples R China
关键词
Aptamer biosensor; ECL aptamer biosensor; Junction-probe; Thrombin; Electrochemiluminescence; SOLID-STATE ELECTROCHEMILUMINESCENCE; SEQUENCE-SPECIFIC DETECTION; ELECTROGENERATED CHEMILUMINESCENCE; MOLECULAR BEACON; DNA DETECTION; PROTEIN; FERROCENE; SELECTION; RU(BPY)(3)(2+); APTASENSORS;
D O I
10.1016/j.bios.2010.11.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0 x 10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2645 / 2650
页数:6
相关论文
共 39 条
[1]   Surface plasmon resonance-based trace detection of small molecules by competitive and signal enhancement immunoreaction [J].
Aizawa, Hidenobu ;
Tozuka, Mitsuhiro ;
Kurosawa, Shigeru ;
Kobayashi, Koichi ;
Reddy, Subrayal M. ;
Higuchi, Masahiro .
ANALYTICA CHIMICA ACTA, 2007, 591 (02) :191-194
[2]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[3]   In vitro selection of DNA aptamers to anthrax spores with electrochemiluminescence detection [J].
Bruno, JG ;
Kiel, JL .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :457-464
[4]   Use of magnetic beads in selection and detection of biotoxin aptamers by electrochemiluminescence and enzymatic methods [J].
Bruno, JG ;
Kiel, JL .
BIOTECHNIQUES, 2002, 32 (01) :178-+
[5]   Quenching of the electrochemiluminescence of tris( 2,2′-bipyridine) ruthenium(II) by ferrocene and its potential application to quantitative DNA detection [J].
Cao, Weidong ;
Ferrance, Jerome P. ;
Demas, James ;
Landers, James P. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (23) :7572-7578
[6]   Molecular aptamers for real-time protein-protein interaction study [J].
Cao, ZH ;
Tan, WH .
CHEMISTRY-A EUROPEAN JOURNAL, 2005, 11 (15) :4502-4508
[7]   Aptamer-based biosensors for label-free voltammetric detection of lysozyme [J].
Cheng, Alan K. H. ;
Ge, Bixia ;
Yu, Hua-Zhong .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5158-5164
[8]   ORGANIZATION OF AU COLLOIDS AS MONOLAYER FILMS ONTO ITO GLASS SURFACES - APPLICATION OF THE METAL COLLOID FILMS AS BASE INTERFACES TO CONSTRUCT REDOX-ACTIVE MONOLAYERS [J].
DORON, A ;
KATZ, E ;
WILLNER, I .
LANGMUIR, 1995, 11 (04) :1313-1317
[9]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[10]   Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA [J].
Fan, CH ;
Plaxco, KW ;
Heeger, AJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (16) :9134-9137