共 39 条
A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe
被引:75
作者:
Zhang, Jing
[1
,2
]
Chen, Pingping
[1
]
Wu, XiaoYan
[1
]
Chen, JingHua
[1
,3
]
Xu, LiangJun
[1
]
Chen, GuoNan
[1
]
Fu, FengFu
[1
]
机构:
[1] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Key Lab Anal & Detect Food Safety,Minist Educ, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Coll Med Occupat & Technol, Dept Pharmaceut, Fuzhou 350101, Fujian, Peoples R China
[3] Fujian Med Univ, Fac Pharm, Dept Pharmaceut Anal, Fuzhou 350004, Fujian, Peoples R China
关键词:
Aptamer biosensor;
ECL aptamer biosensor;
Junction-probe;
Thrombin;
Electrochemiluminescence;
SOLID-STATE ELECTROCHEMILUMINESCENCE;
SEQUENCE-SPECIFIC DETECTION;
ELECTROGENERATED CHEMILUMINESCENCE;
MOLECULAR BEACON;
DNA DETECTION;
PROTEIN;
FERROCENE;
SELECTION;
RU(BPY)(3)(2+);
APTASENSORS;
D O I:
10.1016/j.bios.2010.11.028
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0 x 10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection. (C) 2010 Elsevier B.V. All rights reserved.