Tremor amplitude determination for use in clinical applications

被引:10
作者
Slack, Paul S. [1 ]
Ma, Xianghong [1 ]
机构
[1] Aston Univ, Clin Biomed Engn Res Grp, Birmingham B4 7ET, W Midlands, England
基金
英国工程与自然科学研究理事会;
关键词
surgical tremor determination; micro-surgery; empirical mode decomposition; proper orthogonal decomposition;
D O I
10.1088/0957-0233/18/11/030
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents new methodologies for measuring the hand tremor of surgeons. A means to measure and evaluate the surgeon hand tremor in real time during operating practice can serve to assess the ergonomics of operating conditions. Tremor information is also important for determining surgical performance, particularly in microsurgical tasks. Micro-surgeons often work continuously for several hours with the most complex part occurring toward the end of the procedure. During these procedures the surgeon often uses a binocular microscope and is working at the threshold of perception and manual tool point control. The resulting performance is sensitive to hand tremor. In this paper, maximum tremor amplitude was determined by integrating the acceleration signals measured from three-axis piezoelectric accelerometers. New methods of removing the drift in the acceleration signals through empirical mode decomposition, and of determining the maximum tremor amplitude through proper orthogonal decomposition are presented. An experimental calibration demonstrates that the average error between the maximum tremor calculated by the proposed new method and the measured amplitude is below 5%. The paper also presents the results of the new techniques applied in the operating room in practice. Some of the tasks investigated focused on tool control in microsurgery.
引用
收藏
页码:3471 / 3478
页数:8
相关论文
共 20 条
[1]   Quantitative analysis of finger motion coordination in hand manipulative and gestic acts [J].
Braido, P ;
Zhang, XD .
HUMAN MOVEMENT SCIENCE, 2004, 22 (06) :661-678
[2]   Mechanical accuracy of a new stereotactic guide [J].
Brommeland, T ;
Hennig, R .
ACTA NEUROCHIRURGICA, 2000, 142 (04) :449-454
[3]   Characteristics of physiologic tremor in young and elderly adults [J].
Elble, RJ .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (04) :624-635
[4]   Effect of exercise on microsurgical hand tremor [J].
Hsu, PA ;
Cooley, BC .
MICROSURGERY, 2003, 23 (04) :323-327
[5]  
Huang NE, 2005, INTERD MATH SCI, V5, P1, DOI 10.1142/9789812703347
[6]   THE LEARNING-CURVE IN STAPES SURGERY [J].
HUGHES, GB .
LARYNGOSCOPE, 1991, 101 (12) :1280-1284
[7]   A note on analyzing nonlinear and nonstationary ocean wave data. [J].
Hwang, PA ;
Huang, NE ;
Wang, DW .
APPLIED OCEAN RESEARCH, 2003, 25 (04) :187-193
[8]  
Kreyszig E., 1999, Advanced Engineering Mathematics, Veightth
[9]  
Morris GDL, 2005, CHEM WEEK, V167, P21
[10]   Postural and resting tremor in the upper limb [J].
Morrison, S ;
Newell, KM .
CLINICAL NEUROPHYSIOLOGY, 2000, 111 (04) :651-663