Solid-phase microextraction-gas chromatographic-tandem mass spectrometric analysis of polycyclic aromatic hydrocarbons towards the European Union water directive 2006/0129 EC

被引:68
作者
Fernandez-Gonzalez, V. [1 ,2 ]
Concha-Grana, E. [1 ]
Muniategui-Lorenzo, S. [1 ]
Lopez-Mahia, P. [1 ,2 ]
Prada-Rodriguez, D. [1 ,2 ]
机构
[1] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
[2] Univ Inst Environm, E-15179 La Coruna, Spain
关键词
solid-phase microextraction; water analysis; PAHs; GC-MS; GC-MS-MS; matrix effects;
D O I
10.1016/j.chroma.2007.11.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article presents a solid-phase microextraction (SPME) procedure to determine 27 parent and alkylated polycyclic aromatic hydrocarbons (PAHs) with diverging polarities and molecular masses in various types of water samples (tap, well, superficial, and seawater). A 65-mu m polydimethylsiloxane-divinylbenzene (PDMS/DVB) fiber was used, and parameters affecting the extraction procedures such as extraction temperature and time, desorption temperature and time, splitless time, effect of an organic modifier or ionic adjustment were studied. The linearity and precision of the proposed method were satisfactory. The use of GC-MS determination in the full scan mode, in the selected ion monitoring (SIM) mode, and in the GC-MS-MS mode provided the unequivocal identification and quantification of the target analytes. Moreover, the proposed SPME-GC-MS-MS method, extracting only 18 ml of sample, reached the very restrictive limits fixed by the 2006/0129 EC proposal for a new water directive to be achieved by 2015. The matrix effects were evaluated through the analysis of tap, well, superficial, and seawater. A discussion on different behaviors, a result of the matrix effects, was included. Analytical recoveries were satisfactory in all cases. The novelty of this work consisted in the wide range of analyzed PAHs, the very low detection limits that were reached, the coupling of SPME-GC-MS-MS, and the study of the matrix effect on water samples. With this developed procedure, detection limits between 0.07 and 0.76 ng 1(-1) and quantification limits between 0.10 and 0.98 ng 1(-1) were obtained with MS-MS detection. Moreover, the analytical recoveries for different aqueous matrices were near 100% in all cases. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 30 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[4]  
2-4
[5]   Optimisation and validation of a solid-phase microextraction method for simultaneous determination of different types of pesticides in water by gas chromatography-mass spectrometry [J].
Beceiro-Gonzalez, E. ;
Concha-Grana, E. ;
Guimaraes, A. ;
Goncalves, C. ;
Muniategui-Lorenzo, S. ;
Alpendurada, M. F. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (02) :165-173
[6]   Origin and distribution of polyaromatic hydrocarbons and polychlorobiphenyls in urban effluents to wastewater treatment plants of the Paris area (France) [J].
Blanchard, M ;
Teil, MJ ;
Ollivon, D ;
Garban, B ;
Chestérikoff, C ;
Chevreuil, M .
WATER RESEARCH, 2001, 35 (15) :3679-3687
[7]   Solid-phase microextraction and gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in environmental solid matrices [J].
Cam, D ;
Gagni, S ;
Lombardi, N ;
Punin, MO .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (06) :329-335
[8]   Analysis of polycyclic aromatic hydrocarbons in wastewater treatment plant effluents using hollow fibre liquid-phase microextraction [J].
Charalabaki, M ;
Psillakis, E ;
Mantzavinos, D ;
Kalogerakis, N .
CHEMOSPHERE, 2005, 60 (05) :690-698
[9]   Determination of polycyclic aromatic hydrocarbons in water by solid-phase microextraction and liquid chromatography [J].
Chen, HW .
ANALYTICAL SCIENCES, 2004, 20 (10) :1383-1388
[10]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175