No significant difference in clinically relevant findings between Pillcam® SB3 and Pillcam® SB2 capsules in a United States veteran population

被引:5
作者
Aasen, Tyler D. [1 ]
Wilhoite, David [1 ]
Rahman, Aynur [1 ]
Devani, Kalpit [1 ]
Young, Mark [1 ]
Swenson, James [2 ]
机构
[1] East Tennessee State Univ, Quillen Coll Med, Gastroenterol Sect, 178 W Maple St, Johnson City, TN 37604 USA
[2] Mt Home Vet Affairs Healthcare Syst, Gastroenterol Sect, Mountain Home, TN 37684 USA
关键词
Capsule Endoscopy; Veterans; Retrospective studies; Capsules; Gastrointestinal diseases; SB3; SB2; DIAGNOSTIC YIELD; ENDOSCOPY; MANAGEMENT; IMPACT; EXPERIENCE; OUTCOMES;
D O I
10.4253/wjge.v11.i2.124
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND Capsule endoscopy (CE) allows for a non-invasive small bowel evaluation for a wide range of gastrointestinal (GI) symptoms and diseases. Capsule technology has been rapidly advancing over recent years, often improving image frequency and quality. The Pillcam (R) 5 SB3 (SB3) capsule is one such technology that offers an adaptive frame rate advantage over the previous versions of the capsule the Pillcam (R) SB2 (SB2). Some have proposed that this improvement in capsule technology may lead to increased diagnostic yields; however, real world clinical data is currently lacking. AIM To evaluate the clinically relevant findings of SB3 and SB2 capsules in a population of United States veterans. METHODS A retrospective analysis of 260 consecutive CE studies was performed including 130 SB3 and 130 SB2 capsule studies. Recorded variables included: age, gender, type of capsule, body mass index, exam completion, inpatient status, opioid use, diabetes, quality of preparation, gastric transit time, small bowel transit time, indication, finding, and if the exam resulted in a change in clinical management. The primary outcome measured was the detection of clinically relevant findings between SB3 and SB2 capsules. RESULTS Mean age of the study population was 67.1 +/- 10.4 years and 94.2% of patients were male. Of these 28.1% were on opioid users. The most common indications for capsule procedure were occult GI bleeding (74.6%) and overt GI bleeding (14.6%). Rates of incomplete exam were similar between SB3 and SB2 groups (16.9% vs 9.2%, P = 0.066). The overall rate of clinically relevant finding was 48.9% in our study. No significant difference was observed in SB3 vs SB2 capsules for clinically relevant findings (46.2% vs 51.5%, P = 0.385) or change in clinical management (40.8% vs 50.0%, P = 0.135). CONCLUSION Our study found no significant difference in clinically relevant findings between SB3 and SB2 capsules.
引用
收藏
页码:124 / 132
页数:9
相关论文
共 30 条
[1]  
Adler S., PILLCAM SB3 CAPSULE
[2]   Clinical impact of capsule endoscopy on management of gastrointestinal disorders [J].
Ahmad, Nuzhat A. ;
Iqbal, Nayyar ;
Joyce, Annemarie .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (04) :433-437
[3]  
[Anonymous], 2018, PILLCAM SB3 PROD BRO
[4]  
Barnett Cody B, 2007, Gastroenterol Hepatol (N Y), V3, P124
[5]   A multicenter, prospective, randomized comparison of a novel signal transmission capsule endoscope to an existing capsule endoscope [J].
Choi, Eric H. ;
Mergener, Klaus ;
Semrad, Carol ;
Fisher, Laurel ;
Cave, David R. ;
Dodig, Milan ;
Burke, Carol ;
Leighton, Jonathan A. ;
Kastenberg, David ;
Simpson, Peter ;
Sul, James ;
Bhattacharya, Kanishka ;
Charles, Roger ;
Gerson, Lauren ;
Weber, Luke ;
Eisen, Glenn ;
Reidel, Warren ;
Vargo, John J. ;
Wakim-Fleming, Jamile ;
Lo, Simon K. .
GASTROINTESTINAL ENDOSCOPY, 2013, 78 (02) :325-332
[6]   IS IT WORTH REPEATING PREVIOUS UNREMARKABLE SB2 CAPSULES WITH THE NEW SB3? [J].
Dunn, S. ;
Bevan, R. ;
Neilson, L. ;
Keay, R. ;
Davison, C. ;
Butt, F. ;
Panter, S. .
GUT, 2014, 63 :A61-A62
[7]   Clinical Practice Guidelines for the Use of Video Capsule Endoscopy [J].
Enns, Robert A. ;
Hookey, Lawrence ;
Armstrong, David ;
Bernstein, Charles N. ;
Heitman, Steven J. ;
Teshima, Christopher ;
Leontiadis, Grigorios I. ;
Tse, Frances ;
Sadowski, Daniel .
GASTROENTEROLOGY, 2017, 152 (03) :497-514
[8]   Capsule endoscopy capture rate: Has 4 frames-per-second any impact over 2 frames-per-second? [J].
Fernandez-Urien, Ignacio ;
Carretero, Cristina ;
Borobio, Erika ;
Borda, Ana ;
Estevez, Emilio ;
Galter, Sara ;
Gonzalez-Suarez, Begona ;
Gonzalez, Benito ;
Lujan, Marisol ;
Luis Martinez, Jose ;
Martinez, Vanessa ;
Menchen, Pedro ;
Navajas, Javier ;
Pons, Vicente ;
Prieto, Cesar ;
Valle, Julio .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (39) :14472-14478
[9]   Capsule endoscopy: Present status and future expectation [J].
Goenka, Mahesh K. ;
Majumder, Shounak ;
Goenka, Usha .
WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (29) :10024-10037
[10]  
Grigg-Gutierrez N, 2016, P R HEALTH SCI J, V35, P93