Patency of Branches after Coverage with Multiple Telescoping Flow-Diverter Devices: An In Vivo Study in Rabbits

被引:37
作者
Dai, D. [1 ]
Ding, Y. H. [1 ]
Kadirvel, R. [1 ]
Rad, A. E. [1 ]
Lewis, D. A. [1 ]
Kallmes, D. F. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Neuroradiol Res Lab, Rochester, MN 55905 USA
关键词
PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; DISRUPTING DEVICE; RECONSTRUCTION; ARTERY;
D O I
10.3174/ajnr.A2879
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The safety of placing multiple overlapped endoluminal flow diverters remains unclear because small eloquent branch arteries theoretically could become occluded by these devices. We placed single and multiple flow diverters over small branch arteries in rabbit aortas to determine the incidence of branch artery occlusion. MATERIALS AND METHODS: Flow diverters (PED) were placed into 22 female New Zealand white rabbits abdominal aortas to cover >= 1 lumbar artery. Animals were divided into 3 groups (single PED, n = 9; double PED with 2 telescoped/overlapped devices, n = 7; and triple PED, with 3 telescoped/overlapped devices, n = 6) and were followed for 6 or 12 months. DSA was performed at follow-up. Subsequently, the tissue was processed, sectioned, and stained with H&E for histologic evaluation, histomorphometry, and analysis. RESULTS: All the lumbar arteries covered by devices were clearly patent on angiography. Partial neointima covered the ostia of the branch vessels, but demonstrable patent lumens at the ostia in all cases were present. Neointima hyperplasia was minimal in the single-PED-group animals. The measured neointima was thicker for the double- and triple-PED groups compared with the single-PED group (P < .05). However, in all groups, the mean thickness of the neointima was <= 0.2 mm, and the percentage stenosis of the parent artery was <15% and 18% for 6 and 12 months, respectively. There was no significant inflammatory response in any group. CONCLUSIONS: Small branch arteries remain patent even when covered by multiple overlapped PED flow-diverter devices.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 14 条
[1]   Endovascular treatment of a fusiform basilar artery aneurysm using multiple "in-stent stents" Technical note [J].
Crowley, R. Webster ;
Evans, Avery J. ;
Kassell, Neal F. ;
Jensen, Mary E. ;
Dumont, Aaron S. .
JOURNAL OF NEUROSURGERY-PEDIATRICS, 2009, 3 (06) :496-500
[2]   Bone formation in elastase-induced rabbit aneurysms embolized with platinum coils: Report of 2 cases [J].
Dai, D. ;
Ding, Y. H. ;
Kadirvel, R. ;
Lewis, D. A. ;
Cloft, H. J. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (06) :1176-1178
[3]   Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device [J].
Fiorella, David ;
Woo, Henry H. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2008, 62 (05) :1115-1120
[4]   CURATIVE RECONSTRUCTION OF A GIANT MIDBASILAR TRUNK ANEURYSM WITH THE PIPELINE EMBOLIZATION DEVICE [J].
Fiorella, David ;
Kelly, Michael E. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2009, 64 (02) :212-217
[5]   A Second-Generation, Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms [J].
Kallmes, D. F. ;
Ding, Y. H. ;
Dai, D. ;
Kadirvel, R. ;
Lewis, D. A. ;
Cloft, H. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (06) :1153-1158
[6]   A new endoluminal, flow-disrupting device for treatment of saccular aneurysms [J].
Kallmes, David F. ;
Ding, Yong Hong ;
Dai, Daying ;
Kadirvel, Ramanathan ;
Lewis, Debra A. ;
Cloft, Harry J. .
STROKE, 2007, 38 (08) :2346-2352
[7]   High-Profile Flow Diverter (Silk) Implantation in the Basilar Artery Efficacy in the Treatment of Aneurysms and the Role of the Perforators [J].
Kulcsar, Zsolt ;
Ernemann, Ulrike ;
Wetzel, Stephan G. ;
Bock, Alexander ;
Goericke, Sophia ;
Panagiotopoulos, Vasilis ;
Forsting, Michael ;
Ruefenacht, Daniel A. ;
Wanke, Isabel .
STROKE, 2010, 41 (08) :1690-1696
[8]   CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE [J].
Lylyk, Pedro ;
Miranda, Carlos ;
Ceratto, Rosana ;
Ferrario, Angel ;
Scrivano, Esteban ;
Luna, Hugh Ramirez ;
Berez, Aaron L. ;
Tran, Quang ;
Nelson, Peter K. ;
Fiorella, David .
NEUROSURGERY, 2009, 64 (04) :632-642
[9]   The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial [J].
Nelson, P. K. ;
Lylyk, P. ;
Szikora, I. ;
Wetzel, S. G. ;
Wanke, I. ;
Fiorella, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :34-40
[10]   CARTILAGE AND BONE NEOFORMATION IN RABBIT CAROTID BIFURCATION ANEURYSMS AFTER ENDOVASCULAR COIL EMBOLIZATION [J].
Plenk, H., Jr. ;
Shum, J. C. ;
Cruise, G. M. ;
Killer, M. .
EUROPEAN CELLS & MATERIALS, 2008, 16 :69-79