Reversed phase liquid chromatography method with fluorescence detection of gemifloxacin in rat plasma and its application to the pharmacokinetic study

被引:19
作者
Kaiser, Moacir [2 ]
Gruenspan, Lauren D. [1 ]
Dalla Costa, Teresa [2 ]
Tasso, Leandro [1 ]
机构
[1] UCS, Lab Fisiol & Farmacol, Curso Farm, BR-95020972 Caxias Do Sul, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Fac Farm, Ctr Bioanalit Med, BR-90610000 Porto Alegre, RS, Brazil
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2011年 / 879卷 / 30期
关键词
LC; Gemifloxacin; Fluorescence detection; Rat plasma; Pharmacokinetics; SPECTROPHOTOMETRIC DETERMINATION; PHARMACEUTICAL FORMULATIONS; HEALTHY-VOLUNTEERS; MASS-SPECTROMETRY; TOLERABILITY; MESYLATE;
D O I
10.1016/j.jchromb.2011.09.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and all samples and standard solutions were chromatographed at 45 C using triethylamine solution (0.5%, v/v, pH 3.0 +/- 0.1), methanol and acetonitrile (63:30:7, v/v/v) as the mobile phase. Chromatographic resolution was achieved using a RP-C(18) column (Atlantis, Waters, 150 mm x 4.6 mm, 5 mu m) at a flow rate of 1.0 mL min(-1) and an injection volume of 30 mu L. The analytes were measured by fluorescence detection with excitation and emission wavelengths of 344 nm and 399 nm, respectively. The retention times for GEM and I.S. were approximately 7.5 and 12.6 min, respectively. The lower limit of quantitation (LLOQ) was 20 ng mL(-1) and the calibration curves were linear over a concentration range of 20-5000 ng mL(-1). The intra- and inter-day precisions, expressed by relative standard deviation (R.S.D.) were lower than 6.24% and 4.49%, respectively. The accuracy ranged from 91.3% to 112% and from 98.8% to 106% for the lower and upper limit of quantitation of the calibration curve, respectively. Ratio of peak area of analyte to I.S. was used for quantification of plasma samples. No interferences from endogenous substances were found. The recovery of GEM and I.S. from plasma was greater than 90%. Drug stability in plasma was shown at room temperature for 4 h. after three freeze-thaw cycles for 24 h, in freezer at -80 degrees C for 60 days, and in the autosampler after processing for 12 h. The utility of the assay was confirmed by the successful analysis of plasma samples from GEM pharmacokinetics studies in the rats after intravenous administration. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3639 / 3644
页数:6
相关论文
共 18 条
  • [1] Validated liquid chromatographic-fluorescence method for the quantitation of gemifloxacin in human plasma
    Al-Hadiya, Badraddin M. H.
    Khady, Adnan A.
    Mostafa, Gamal A. E.
    [J]. TALANTA, 2010, 83 (01) : 110 - 116
  • [2] Pharmacokinetics and tolerability of gemifloxacin (SB-265805) after administration of single oral doses to healthy volunteers
    Allen, A
    Bygate, E
    Oliver, S
    Johnson, M
    Ward, C
    Cheon, AJ
    Choo, YS
    Kim, IC
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2000, 44 (06) : 1604 - 1608
  • [3] Multiple-dose pharmacokinetics and tolerability of gemifloxacin administered orally to healthy volunteers
    Allen, A
    Bygate, E
    Vousden, M
    Oliver, S
    Johnson, M
    Ward, C
    Cheon, AJ
    Choo, YS
    Kim, IC
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2001, 45 (02) : 540 - 545
  • [4] [Anonymous], 2001, FDA Guidance for industry: Bioanalytical method validation
  • [5] A new respiratory fluoroquinolone, oral gemifloxacin: a safety profile in context
    Ball, P
    Mandell, L
    Patou, G
    Dankner, W
    Tillotson, G
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2004, 23 (05) : 421 - 429
  • [6] BIKASH R, 2010, J PHARM BIOMED ANAL, V52, P216
  • [7] Antimicrobial activity and spectrum of LB20304, a novel fluoronaphthyridone
    Cormican, MG
    Jones, RN
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1997, 41 (01) : 204 - 211
  • [8] Rapid determination of gemifloxacin in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Doyle, E
    Fowles, SE
    McDonnell, DF
    McCarthy, R
    White, SA
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 746 (02): : 191 - 198
  • [9] Community-acquired pneumonia in northern Australia: low mortality in a tropical region using locally-developed treatment guidelines
    Elliott, JH
    Anstey, NM
    Jacups, SP
    Fisher, DA
    Currie, BJ
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2005, 9 (01) : 15 - 20
  • [10] Potent antipneumococcal activity of gemifloxacin is associated with dual targeting of gyrase and topoisomerase IV, an in vivo target preference for gyrase, and enhanced stabilization of cleavable complexes in vitro
    Heaton, VJ
    Ambler, JE
    Fisher, LM
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2000, 44 (11) : 3112 - 3117