Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: A subjective comparison

被引:26
作者
Piraino, DW [1 ]
Davros, WJ [1 ]
Lieber, M [1 ]
Richmond, BJ [1 ]
Schils, JP [1 ]
Recht, MP [1 ]
Grooff, PN [1 ]
Belhobek, GH [1 ]
机构
[1] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
关键词
D O I
10.2214/ajr.172.1.9888764
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to subjectively compare the visibility of normal anatomy of the hands and feet using selenium-based digital radiography versus conventional film-screen (100-speed) radiography. SUBJECTS AND METHODS. Digital and film-screen images of the hands and feet of 24 patients were obtained without an antiscatter grid using identical X-ray exposure. Each pair of images was evaluated independently by five experienced radiologists for visibility of normal anatomy using a six-point rating scale. Soft tissues, cortical bone, and trabeculae were evaluated. For each observer, "equivalence" was defined as a mean difference in image quality of less than 1 unit on the 0-5 scale used in the study. Paired t tests were also performed to determine whether the average visibility rating of one technique was statistically superior to that of the other at a .05 level of significance for each observer and at each anatomic landmark. RESULTS. In all categories, selenium-based digital images were rated equivalent to film-screen images by the five observers. Using the sum of the nine landmarks, four of the ve observers rated the quality of selenium-based digital images superior to that of film-screen images. CONCLUSION. Subjective visibility of normal anatomy of the hands and feet using selenium-based digital radiography was similar to that achieved using conventional film-screen radiography.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 8 条
[1]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[2]   Radiographic imaging characteristics of a direct conversion detector using selenium and thin film transistor array [J].
Lee, DL ;
Cheung, LK ;
Jeromin, LS ;
Palecki, EF ;
Rodricks, B .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :88-96
[3]  
LEE DY, 1996, COMPUTER ASSISTED RA, P83
[4]   Testing for equivalence of diagnostic tests [J].
Obuchowski, NA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (01) :13-17
[5]   Automatic detection of the useful image data from digital x-ray detectors [J].
Schwenker, RP ;
Jeromin, LS ;
Lee, DL ;
Williams, CL .
IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 :204-209
[6]  
Shaber GS, 1997, INT CONGR SER, V1134, P39
[7]  
SLONE RM, 1996, RADIOLOGY, V201, P400
[8]   Chest radiography: Depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography [J].
Woodard, PK ;
Slone, RM ;
Gierada, DS ;
Reiker, GG ;
Pilgram, TK ;
Jost, RG .
RADIOLOGY, 1997, 203 (01) :197-201