Seismic Performance of GFRP-Reinforced Concrete Rectangular Columns

被引:108
作者
Ali, Mahmoud A. [1 ]
El-Salakawy, Ehab [1 ,2 ]
机构
[1] Univ Manitoba, Dept Civil Engn, Winnipeg, MB R3T 5V6, Canada
[2] Univ Manitoba, Dept Civil Engn, Durabil & Modernizat Civil Struct, Winnipeg, MB R3T 5V6, Canada
关键词
Glass-fiber reinforced polymers (GFRP); Columns; Confinement; Reinforced concrete; Seismic; POLYMER BARS; STRENGTH; BEHAVIOR; CANADA;
D O I
10.1061/(ASCE)CC.1943-5614.0000637
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an assessment of the seismic performance of concrete columns internally reinforced with glass-fiber-reinforced polymers (GFRP) bars. Eight full-scale column prototypes with 1,650-mm shear span and 350-mm square cross-section were constructed and tested under combined lateral cyclic quasi-static and constant axial loading. The test specimens represent the lower portion of first-story columns between the footing and the contra-flexure point. The test parameters included longitudinal reinforcement type and ratio, level of axial load, and stirrup spacing. Test results showed that the drift capacity of GFRP-reinforced concrete (RC) rectangular columns at failure ranged between 8.5 and 12.5%, which exceeds the limitations of North American building codes. This indicates that the deformability of GFRP-RC column prototypes successfully replaced the ductility in steel-RC columns in dissipating the seismic energy in the presence of constant axial load. Furthermore, there was insignificant strength degradation before failure due to the well-confined concrete core. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 19 条
[1]  
ACI Committee 374, 2005, ACI 374.1-05
[2]  
ACI Committee 440, 2015, ACI 440.1R-15, P83
[3]  
Alsayed S. H., 1999, SPECIAL PUBLICATION, P103
[4]  
[Anonymous], 2004, DESIGN CONCRETE STRU, P214
[5]  
[Anonymous], 2014, A23314 CSA, P214
[6]  
[Anonymous], 2012, S80612 CSA, P177
[7]   Fibre reinforced polymer composite bars for the structural concrete slabs of a Public Works and Government Services Canada parking garage [J].
Benmokrane, B ;
El-Salakawy, E ;
Cherrak, Z ;
Wiseman, A .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 2004, 31 (05) :732-748
[8]  
Choo CC, 2006, ACI STRUCT J, V103, P460
[9]  
Choo CC, 2006, ACI STRUCT J, V103, P452
[10]  
De Luca A, 2009, 9 INT S FIB REINF PO