Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice

被引:643
作者
Mukkamala, Ramakrishna [1 ]
Hahn, Jin-Oh [2 ]
Inan, Omer T. [3 ]
Mestha, Lalit K. [4 ]
Kim, Chang-Sei [2 ]
Toreyin, Hakan [3 ]
Kyal, Survi [4 ]
机构
[1] Michigan State Univ, Dept Elect & Comp Engn, Fac, E Lansing, MI 48824 USA
[2] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[3] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[4] Palo Alto Res Ctr East, Webster, NY USA
基金
美国国家卫生研究院;
关键词
Cuff-less blood pressure (BP); pulse transit time (PTT); pulse wave velocity (PWV); review; ubiquitous sensing; wearable; NUTRITION EXAMINATION SURVEY; MOTION-ARTIFACT REDUCTION; SENSOR CONTACT FORCE; WAVE VELOCITY; SMOOTH-MUSCLE; ELASTIC PROPERTIES; ARRIVAL-TIME; HEART-RATE; IMPEDANCE CARDIOGRAPHY; ARTERIAL STIFFNESS;
D O I
10.1109/TBME.2015.2441951
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work toward putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach.
引用
收藏
页码:1879 / 1901
页数:23
相关论文
共 215 条
[51]  
Drzewiecki G. M., 1984, DEFORMATIONAL FORCES, V28, P642
[52]  
Eckerle J.S., 1988, ENCY MED DEVICES INS
[53]  
Electronic or Automated Sphygmomanometers, 1993, SP10192 ANSI AAMI
[54]   Rapid Assessment of Cardiac Contractility on a Home Bathroom Scale [J].
Etemadi, Mozziyar ;
Inan, Omer T. ;
Giovangrandi, Laurent ;
Kovacs, Gregory T. A. .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (06) :864-869
[55]   Invited review: Aging and the cardiovascular system [J].
Ferrari, AU ;
Radaelli, A ;
Centola, M .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (06) :2591-2597
[56]   BETA-RECEPTOR ACTIVITY IN AORTA . VARIATIONS WITH AGE AND SPECIES [J].
FLEISCH, JH ;
MALING, HM ;
BRODIE, BB .
CIRCULATION RESEARCH, 1970, 26 (02) :151-&
[57]   Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence [J].
Forouzanfar, Mohamad ;
Ahmad, Saif ;
Batkin, Izmail ;
Dajani, Hilmi R. ;
Groza, Voicu Z. ;
Bolic, Miodrag .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) :1814-1824
[58]   Predominance of isolated systolic hypertension among middle-aged and elderly US hypertensives - Analysis based on National Health and Nutrition Examination Survey (NHANES) III [J].
Franklin, SS ;
Jacobs, MJ ;
Wong, ND ;
L'Italien, GJ ;
Lapuerta, P .
HYPERTENSION, 2001, 37 (03) :869-874
[59]  
Froelicher VF., 2006, Exercise and the heart, V5th
[60]   Large artery remodeling during aging - Biaxial passive and active stiffness [J].
Gaballa, MA ;
Jacob, CT ;
Raya, TE ;
Liu, J ;
Simon, B ;
Goldman, S .
HYPERTENSION, 1998, 32 (03) :437-443