Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique

被引:98
作者
Scheffel, Hans
Stolzmann, Paul
Schlett, Christopher L.
Engel, Leif-Christopher
Major, Gyoengi Petra
Karolyi, Mihaly
Do, Synho
Maurovich-Horvat, Pal
Hoffmann, Udo [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Dept Radiol, Boston, MA 02144 USA
[2] Harvard Univ, Sch Med, Boston, MA 02144 USA
关键词
Adaptive statistical iterative reconstruction; Model-based iterative reconstruction; CT angiography; Plaque visualization; Image quality; MULTIDETECTOR COMPUTED-TOMOGRAPHY; IMPROVED IMAGE QUALITY; INTRAVASCULAR ULTRASOUND; INTRACORONARY ULTRASOUND; ANGIOGRAPHY; ACCURACY; EXPERIENCE; CHEST; CALCIUM; DISEASE;
D O I
10.1016/j.ejrad.2011.11.051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare image quality of coronary artery plaque visualization at CT angiography with images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model based iterative reconstruction (MBIR) techniques. Methods: The coronary arteries of three ex vivo human hearts were imaged by CT and reconstructed with FBP, ASIR and MBIR. Coronary cross-sectional images were co-registered between the different reconstruction techniques and assessed for qualitative and quantitative image quality parameters. Readers were blinded to the reconstruction algorithm. Results: A total of 375 triplets of coronary cross-sectional images were co-registered. Using MBIR, 26% of the images were rated as having excellent overall image quality, which was significantly better as compared to ASIR and FBP (4% and 13%, respectively, all p < 0.001). Qualitative assessment of image noise demonstrated a noise reduction by using ASIR as compared to FBP (p < 0.01) and further noise reduction by using MBIR (p < 0.001). The contrast-to-noise-ratio (CNR) using MBIR was better as compared to ASIR and FBP (44 +/- 19, 29 +/- 15, 26 +/- 9, respectively; all p < 0.001). Conclusions: Using MBIR improved image quality, reduced image noise and increased CNR as compared to the other available reconstruction techniques. This may further improve the visualization of coronary artery plaque and allow radiation reduction. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E363 / E369
页数:7
相关论文
共 20 条
[1]   Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography [J].
Araoz, Philip A. ;
Kirsch, Jacobo ;
Primak, Andrew N. ;
Braun, Natalie N. ;
Saba, Osama ;
Williamson, Eric E. ;
Harmsen, W. Scott ;
Mandrekar, Jayawant N. ;
McCollough, Cynthia H. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) :837-845
[2]   Arterial wall imaging: Evaluation with 16-section multidetector CT in blood vessel phantoms and ex vivo coronary arteries [J].
Ferencik, Maros ;
Chan, Raymond C. ;
Achenbach, Stephan ;
Lisauskas, Jennifer B. ;
Houser, Stuart L. ;
Hoffmann, Udo ;
Abbara, Suhny ;
Cury, Ricardo C. ;
Bouma, Brett E. ;
Tearney, Guillermo J. ;
Brady, Thomas J. .
RADIOLOGY, 2006, 240 (03) :708-716
[3]   Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography [J].
Hoffmann, U ;
Moselewski, F ;
Nieman, K ;
Jang, IK ;
Ferencik, M ;
Rahman, AM ;
Cury, RC ;
Abbara, S ;
Joneidi-Jafari, H ;
Achenbach, S ;
Brady, TJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) :1655-1662
[4]   Coronary multidetector computed tomography in the assessment of patients with acute chest pain [J].
Hoffmann, Udo ;
Nagurney, John T. ;
Moselewski, Fabian ;
Pena, Antonio ;
Ferencik, Maros ;
Chae, Claudia U. ;
Cury, Ricardo C. ;
Butler, Javed ;
Abbara, Suhny ;
Brown, David F. ;
Manini, Alex ;
Nichols, John H. ;
Achenbach, Stephan ;
Brady, Thomas J. .
CIRCULATION, 2006, 114 (21) :2251-2260
[5]   Determination of coronary calcium with Multi-slice Spiral computed tomography: a comparative study with electron-beam CT [J].
Knez, A ;
Becker, C ;
Becker, A ;
Leber, A ;
White, C ;
Reiser, M ;
Steinbeck, G .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (04) :295-303
[6]   Diagnostic accuracy of dual-source multi-slice CT-coronary angiography in patients with an intermediate pretest likelihood for coronary artery disease [J].
Leber, Alexander W. ;
Johnson, Thorsten ;
Becker, Alexander ;
von Ziegler, Franz ;
Tittus, Janine ;
Nikolaou, Konstantin ;
Reiser, Maximilian ;
Steinbeck, Gerhard ;
Becker, Christoph R. ;
Knez, Andreas .
EUROPEAN HEART JOURNAL, 2007, 28 (19) :2354-2360
[7]   Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system - A comparative study using intravascular ultrasound [J].
Leber, AW ;
Becker, A ;
Knez, A ;
von Ziegler, F ;
Sirol, M ;
Nikolaou, K ;
Ohnesorge, B ;
Fayad, ZA ;
Becker, CR ;
Reiser, M ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (03) :672-677
[8]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247
[9]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[10]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487