Retinal nerve fiber layer thickness map determined from optical coherence tomography images

被引:140
作者
Mujat, M
Chan, RC
Cense, B
Park, BH
Joo, C
Akkin, T
Chen, TC
de Boer, JF
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Boston, MA 02114 USA
[2] Wellman Ctr Photomed, Boston, MA 02114 USA
[3] Massachusetts Eye & Ear Infirm, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2005年 / 13卷 / 23期
关键词
D O I
10.1364/OPEX.13.009480
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We introduce a method to determine the retinal nerve fiber layer (RNFL) thickness in OCT images based on anisotropic noise suppression and deformable splines. Spectral-Domain Optical Coherence Tomography (SDOCT) data was acquired at 29 kHz A-line rate with a depth resolution of 2.6 m and a depth range of 1.6 mm. Areas of 9.6x6.4 mm(2) and 6.4x6.4 mm(2) were acquired in approximately 6 seconds. The deformable spline algorithm determined the vitreous-RNFL and RNFL-ganglion cell/inner plexiform layer boundary, respectively, based on changes in the reflectivity, resulting in a quantitative estimation of the RNFL thickness. The thickness map was combined with an integrated reflectance map of the retina and a typical OCT movie to facilitate clinical interpretation of the OCT data. Large area maps of RNFL thickness will permit better longitudinal evaluation of RNFL thinning in glaucoma. (c) 2005 Optical Society of America.
引用
收藏
页码:9480 / 9491
页数:12
相关论文
共 29 条
[1]   Optical coherence tomography assessment of retinal nerve fiber laver thickness changes after glaucoma surgery [J].
Aydin, A ;
Wollstein, G ;
Price, LL ;
Fujimoto, JG ;
Schuman, JS .
OPHTHALMOLOGY, 2003, 110 (08) :1506-1511
[2]  
Barrett R., 1994, Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods, V2nd ed.
[3]   Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments [J].
Bourne, RRA ;
Medeiros, FA ;
Bowd, C ;
Jahanbakhsh, K ;
Zangwill, LM ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) :1280-1285
[4]   Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes [J].
Carpineto, P ;
Ciancaglini, M ;
Zuppardi, E ;
Falconio, G ;
Doronzo, E ;
Mastropasqua, L .
OPHTHALMOLOGY, 2003, 110 (01) :190-195
[5]   Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography [J].
Cense, B ;
Nassif, NA ;
Chen, T ;
Pierce, M ;
Yun, SH ;
Park, BH ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (11) :2435-2447
[6]  
Chan R, 2000, IEEE IMAGE PROC, P160, DOI 10.1109/ICIP.2000.900919
[7]  
CHAN RCK, 2000, IEEE COMPUTERS CARDI, P37
[8]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[9]   Spectral resolution and sampling issues in Fourier-transform spectral interferometry [J].
Dorrer, C ;
Belabas, N ;
Likforman, JP ;
Joffre, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) :1795-1802
[10]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48