Interfacial defects detection in plasma-sprayed ceramic coating components using two stimulated infrared thermography techniques

被引:33
作者
Chaki, S. [1 ]
Marical, P. [1 ]
Panier, S. [1 ]
Bourse, G. [1 ]
Mouftiez, A. [1 ]
机构
[1] Ecole Mines Douai, Dept Technol Polymeres & Composite & Ingn Mecan T, F-59508 Douai, France
关键词
Lock-in thermography; Vibrothermography; Ultrasound stimulation; Thermal stimulation; Ceramic coating; Interfacial defect; NONDESTRUCTIVE EVALUATION;
D O I
10.1016/j.ndteint.2011.05.008
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Two Lock-in InfraRed Thermography (LIRT) techniques were developed and applied to detect interfacial defects in a ceramic coated steel plate deposited by plasma spraying technology. Stimulations were performed either by electromagnetic waves (lamps) or by high power ultrasonic waves (sonotrode). The first one is based on remote optical heating of the area of interest; while the second technique is based on the mechanical loss angle effect, occurring locally and for particular defects such as cracks and delaminations. The potential of these two techniques was evaluated against artificial (calibrated holes) and real (disbonding) interfacial defects. The results show success and also some limitations of both LIRT techniques in function of sizes and depths of ceramic coating interfacial defects. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:519 / 522
页数:4
相关论文
共 17 条
[1]   Aircraft composites assessment by means of transient thermal NDT [J].
Avdelidis, NP ;
Almond, DP ;
Dobbinson, A ;
Hawtin, BC ;
Ibarra-Castanedo, C ;
Maldague, X .
PROGRESS IN AEROSPACE SCIENCES, 2004, 40 (03) :143-162
[2]   THERMAL WAVE IMAGING WITH PHASE SENSITIVE MODULATED THERMOGRAPHY [J].
BUSSE, G ;
WU, D ;
KARPEN, W .
JOURNAL OF APPLIED PHYSICS, 1992, 71 (08) :3962-3965
[3]   Quantitative determination of a subsurface defect of reference specimen by lock-in infrared thermography [J].
Choi, Manyong ;
Kang, Kisoo ;
Park, Jeonghak ;
Kim, Wontae ;
Kim, Koungsuk .
NDT & E INTERNATIONAL, 2008, 41 (02) :119-124
[4]   Comparison between pulsed and modulated thermography in glass-epoxy laminates [J].
Giorleo, G ;
Meola, C .
NDT & E INTERNATIONAL, 2002, 35 (05) :287-292
[5]  
Gleiter A, 2006, P SOC PHOTO-OPT INS, V6205
[6]   Acoustic emission responses of plasma-sprayed alumina-3% titania deposits [J].
Lin, CK ;
Leigh, SH ;
Berndt, CC .
THIN SOLID FILMS, 1997, 310 (1-2) :108-114
[7]   Frictional heating model for efficient use of vibrothermography [J].
Mabrouki, F. ;
Thomas, M. ;
Genest, M. ;
Fahr, A. .
NDT & E INTERNATIONAL, 2009, 42 (05) :345-352
[8]  
Maldague X., 2000, TRENDS OPTICAL NONDE
[9]  
Maldague XPV, 2001, WILEY MICRO, pXV
[10]   Non-destructive evaluation of aerospace materials with lock-in thermography [J].
Meola, C ;
Carlomagno, GM ;
Squillace, A ;
Vitiello, A .
ENGINEERING FAILURE ANALYSIS, 2006, 13 (03) :380-388