Detection of 17β-estradiol in water samples by a novel double-layer molecularly imprinted film-based biosensor

被引:25
作者
Tan, Yuan [1 ]
Wei, Tianxin [1 ]
机构
[1] Beijing Inst Technol, Minist Educ, Key Lab Cluster Sci, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-layer MIF; 17; beta-Estradiol; Surface plasmon resonance (SPR); ENZYME-IMMUNOASSAY; MASS-SPECTROMETRY; FLUORESCENCE IMMUNOASSAY; ASSAY KIT; ESTRADIOL; IMMUNOSENSOR; EXTRACTION; NANOSENSOR; GUIDE;
D O I
10.1016/j.talanta.2015.04.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study reports a novel double-layer molecularly imprinted film (MIF)-based biosensor for rapid, sensitive and highly selective detection of small molecule 17 beta-estradiol (E2) that is frequently detected in environmental water samples. In this system, the modification of gold surface of SPR chip was performed by 1-dodecanethiol. Then double-layer MIF was generated on the 1-dodecanethiol modified gold surface. The non-modified and imprinted surfaces were characterized by atomic force microscopy (AFM), scanning electron microscope (SEM) and contact angle measurements. Analysis of surface plasmon resonance (SPR) spectroscopy showed that the imprinted sensing film displayed good selectivity for E2 compared to other analog molecules and NIF. A good linear relationship was obtained between the SPR angle and E2 concentrations over a range of 2.50 x 10(-13)-2.50 x 10(-9)mol/L (R-2=0.993) with the lowest measurable concentration of 2.50 x 10(-13) mol/L. The sensor can be regenerated with the mixture of acetic acid and PBS buffer (v/v =1:9) as a desorption agent over tens of times without significant deterioration of the sensor performance. Potential interference of real environmental sample matrix was assessed by spiked samples in several waste seawater effluents. This portable sensor system can be successfully applied for on-site real-time inexpensive and easy-to-use monitoring of E2 or other small molecule pollutants in environmental samples such as effluents or water bodies. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 46 条
[21]   Surface plasmon resonance-based immunoassay for 17β-estradiol and its application to the measurement of estrogen receptor-binding activity [J].
Miyashita, M ;
Shimada, T ;
Miyagawa, H ;
Akamatsu, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) :667-673
[22]   Advantages of molecularly imprinted polymers LC-ESI-MS/MS for the selective extraction and quantification of chloramphenicol in milk-based matrixes. Comparison with a classical sample preparation [J].
Mohamed, Rayane ;
Richoz-Payot, Janique ;
Gremaud, Eric ;
Mottier, Pascal ;
Yilmaz, Ecevit ;
Tabet, Jean-Claude ;
Guy, Philippe A. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9557-9565
[23]  
MUNRO CJ, 1991, CLIN CHEM, V37, P838
[24]   Indirect Inhibitive Immunoassay for Estradiol Using Surface Plasmon Resonance Coupled to Online In-Tube SPME [J].
Ou, Huichao ;
Luo, Zhaofeng ;
Jiang, Hao ;
Zhou, Hongmin ;
Wang, Xiaoping ;
Song, Cunxian .
ANALYTICAL LETTERS, 2009, 42 (17) :2758-2773
[25]   Resurveying the Tris buffer solution: The specific interaction between tris(hydroxymethyl)aminomethane and lysozyme [J].
Quan, Li ;
Wei, Dengguo ;
Jiang, Xiaolu ;
Liu, Yang ;
Li, Zhiyu ;
Li, Na ;
Li, Kean ;
Liu, Feng ;
Lai, Luhua .
ANALYTICAL BIOCHEMISTRY, 2008, 378 (02) :144-150
[26]   Molecular imprinting of enzymes with water-insoluble ligands for nonaqueous biocatalysis [J].
Rich, JO ;
Mozhaev, VV ;
Dordick, JS ;
Clark, DS ;
Khmelnitsky, YL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (19) :5254-5255
[27]   Imprinted Au-Nanoparticle Composites for the Ultrasensitive Surface Plasmon Resonance Detection of Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) [J].
Riskin, Michael ;
Tel-Vered, Ran ;
Willner, Itamar .
ADVANCED MATERIALS, 2010, 22 (12) :1387-+
[28]   Superiority of gas chromatography/tandem mass spectrometry assay (GC/MS/MS) for estradiol for monitoring of aromatase inhibitor therapy [J].
Santen, Richard J. ;
Demers, Lawrence ;
Ohorodnik, Susan ;
Settlage, J. ;
Langecker, Peter ;
Blanchett, D. ;
Goss, Paul E. ;
Wang, Shuping .
STEROIDS, 2007, 72 (08) :666-671
[29]  
Sener G., 2011, SENSOR ACTUAT B-CHEM, V160, P791
[30]   Assessing estradiol in biobehavioral studies using saliva and blood spots: Simple radioimmunoassay protocols, reliability, and comparative validity [J].
Shirtcliff, EA ;
Granger, DA ;
Schwartz, EB ;
Curran, MJ ;
Booth, A ;
Overman, WH .
HORMONES AND BEHAVIOR, 2000, 38 (02) :137-147