Determination of cadmium, copper and lead in mineral coal using solid sampling graphite furnace atomic absorption spectrometry

被引:61
作者
Vale, MGR
Silva, MM
Welz, B [1 ]
Lima, ÉC
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
关键词
electrothermal atomic absorption spectrometry; solid sampling; coal analysis; Cd; Cu; Pb determination; Ru permanent modifier;
D O I
10.1016/S0584-8547(01)00336-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS) was investigated as a potential technique for the routine determination of trace elements in mineral coal and cadmium, copper and lead were chosen as the model elements. Cadmium and lead could be determined at their main resonance lines at 228.8 nm and 283.3 nm, respectively, but an alternate, less sensitive line had to be used for the determination of copper because of the high copper content in coal. No modifier was necessary for the determination of copper and calibration against aqueous standards provided sufficient accuracy of the results. For the determination of cadmium and lead two different modifiers were investigated, palladium and magnesium nitrates in solution, added on top of each sample aliquot before introduction into the atomizer tube, and ruthenium as a 'permanent' modifier. Both approaches gave comparable results, and it is believed that this is the first report about the successful use of a permanent chemical modifier in SS-GF AAS. Calibration against solid standards had to be used for the determination of cadmium and lead in order to obtain accurate values. The agreement between the values found by the proposed procedure and the certificate values for a number of coal reference materials was more than acceptable for routine purposes, The detection limits calculated for 1 mg of coal sample using the 'zero mass response' were 0.003 and 0.007 mug g(-1) for cadmium with the permanent modifier and the modifier solution, respectively, approximately 0.04 mug g(-1) for lead, and 0.014 mug g(-1) for copper. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1859 / 1873
页数:15
相关论文
共 51 条
[1]   SOLID SAMPLING IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY USING COMMERCIAL ATOMIZERS - A REVIEW [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (05) :353-374
[2]   RAPID SLURRY ANALYSIS OF SOLID COAL AND FLY-ASH SAMPLES [J].
BRADSHAW, D ;
SLAVIN, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (12) :1245-1256
[3]   ANALYSES OF SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING ZEEMAN BACKGROUND CORRECTION [J].
CARNRICK, GR ;
LUMAS, BK ;
BARNETT, WB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (06) :443-447
[4]   Determination of Ag, Pb and Sn in aqua regia extracts from sediments by electrothermal atomic absorption spectrometry using Ru as a permanent modifier [J].
da Silva, JBB ;
da Silva, MAM ;
Curtius, AJ ;
Welz, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1737-1742
[5]  
DOSEKAL B, 1995, SPECTROCHIM ACTA B, V50, P517
[7]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .7. ANALYSIS OF COAL USING INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
EBDON, L ;
FOULKES, ME ;
PARRY, HGM ;
TYE, CT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (06) :753-761
[8]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .3. WHOLE COAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
EBDON, L ;
WILKINSON, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (03) :325-328
[9]   DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .10. USE OF AN AIR-ASHING STAGE IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
EBDON, L ;
FISHER, AS ;
PARRY, HGM ;
BROWN, AA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (04) :321-324