Bony Impingement Limits Design-related Increases in Hip Range of Motion

被引:23
作者
Bunn, Adam [1 ]
Colwell, Clifford W., Jr. [1 ]
D'Lima, Darryl D. [1 ]
机构
[1] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
关键词
ACETABULAR COMPONENT; EARLY DISLOCATION; NECK GEOMETRY; PRIMARY THA; HEAD SIZE; ARTHROPLASTY; REPLACEMENT; INSTABILITY; OUTCOMES; JOINT;
D O I
10.1007/s11999-011-2096-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Factors affecting risk for impingement and dislocation can be related to the patient, implant design, or surgeon. While these have been studied independently, the impact of each factor relative to the others is not known. We determined the effect of three implant design factors, prosthetic placement, and patient anatomy on subject-specific ROM. We virtually implanted hip geometry obtained from 16 CT scans using computer models of hip components with differences in head size, neck diameter, and neck-shaft angle. A contact detection model computed ROM before prosthetic or bony impingement. We correlated anatomic measurements from pelvic radiographs with ROM. When we implanted the components for best fit to the subject's anatomy or in the recommended orientation of 45A degrees abduction and 20A degrees anteversion, ROM was greater than 110A degrees of flexion, 30A degrees of extension, 45A degrees of adduction-abduction, and 40A degrees of external rotation. Changes in head size, neck diameter, and neck-shaft angle generated small gains (3.6A degrees aEuro"6A degrees) in ROM when analyzed individually, but collectively, we noted a more substantial increase (10A degrees aEuro"17A degrees). Radiographic measurements correlated only moderately with hip flexion and abduction. It is feasible to tailor implant placement to each patient to maximize bony coverage without compromising ROM. Once bony impingement becomes the restricting factor, further changes in implant design may not improve ROM. Radiographic measurements do not appear to have value in predicting ROM.
引用
收藏
页码:418 / 427
页数:10
相关论文
共 49 条
[1]   The influence of head and neck geometry on stability of total hip replacement - A mechanical test study [J].
Bader, R ;
Scholz, R ;
Steinhauser, E ;
Zimmermann, S ;
Busch, R ;
Mittelmeier, W .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (04) :415-421
[2]   Stem design and dislocation after revision total hip arthroplasty - Clinical results and computer modeling [J].
Barrack, RL ;
Butler, RA ;
Laster, DR ;
Andrews, P .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :8-12
[3]   The effect of femoral component head size on posterior dislocation of the artificial hip joint [J].
Bartz, RL ;
Noble, PC ;
Kadakia, NR ;
Tullos, HS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) :1300-1307
[4]   Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11) :2456-2463
[5]   Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[6]  
CHANDLER DR, 1982, CLIN ORTHOP RELAT R, P284
[7]   Total hip replacement in morbidly obese patients with osteoarthritis RESULTS OF A PROSPECTIVELY MATCHED STUDY [J].
Chee, Y. H. ;
Teoh, K. H. ;
Sabnis, B. M. ;
Ballantyne, J. A. ;
Brenkel, I. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1066-1071
[8]   Biomechanics of large femoral heads - What they do and don't do [J].
Crowninshield, RD ;
Maloney, WJ ;
Wentz, DH ;
Humphrey, SM ;
Blanchard, CR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :102-107
[9]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[10]   OPERATIVE CORRECTION OF AN UNSTABLE TOTAL HIP-ARTHROPLASTY [J].
DALY, PJ ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1334-1343