Development of a one-shot optical citrate sensor based on a guanidinium synthetic receptor

被引:23
作者
Capitán-Vallvey, LF
Arroyo-Guerrero, E
Fernández-Ramos, MD
Santoyo-González, F
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
[2] Univ Granada, Fac Sci, Dept Organ Chem, E-18071 Granada, Spain
关键词
citrate determination; one-shot sensor; optical sensor; guanidinium receptor; soft drinks and pharmaceuticals analysis;
D O I
10.1007/s00604-005-0378-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical absorption-based one-shot sensor for the determination of citrate is described. The citrate-sensitive element is a plasticized polymeric membrane containing a synthetic guanidinium receptor and a pH-sensitive lipophilic dye. The rigid amide-based receptor with C-3 symmetry controls the anion selectivity pattern of the optical element. The optical selectivity coefficients obtained for citrate over a variety of common carboxylate anions meet the requirements for the determination of citrate in different types of samples. The one-shot sensor responds rapidly - in 40 s - and reversibly to citrate over a dynamic range of 0.779 to 25.0 mM with a sensor-to-sensor reproducibility of 5.7%, as log a(cit), in the medium level of the range. The performance of the optical one-shot sensor has been tested in the analysis of citrate in soft drinks and pharmaceuticals, validating the results against a reference procedure. The proposed method is quick, inexpensive, selective and sensitive, and uses conventional instrumentation only.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 36 条
  • [1] ANSLYN EV, 2001, Patent No. 6048732
  • [2] ARROYO E, 2003, P C SPECT INT 32 GRA
  • [3] DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES
    BAKKER, E
    WILLER, M
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1993, 282 (02) : 265 - 271
  • [4] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132
  • [5] Beer PD, 2001, ANGEW CHEM INT EDIT, V40, P486, DOI 10.1002/1521-3773(20010202)40:3<486::AID-ANIE486>3.3.CO
  • [6] 2-G
  • [7] Recognition of anions through NH-pi hydrogen bonds in a bicyclic cyclophane-selectivity for nitrate
    Bisson, AP
    Lynch, VM
    Monahan, MKC
    Anslyn, EV
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1997, 36 (21): : 2340 - 2342
  • [8] Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    Buhlmann, P
    Pretsch, E
    Bakker, E
    [J]. CHEMICAL REVIEWS, 1998, 98 (04) : 1593 - 1687
  • [9] Metal triggered fluorescence sensing of citrate using a synthetic receptor
    Cabell, LA
    Best, MD
    Lavigne, JJ
    Schneider, SE
    Perreault, DM
    Monahan, MK
    Anslyn, EV
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 2001, (03): : 315 - 323
  • [10] Characterisation of a transparent optical test strip for quantification of water hardness
    Capitán-Vallvey, LF
    Fernández-Ramos, MD
    Gálvez, PAD
    Santoyo-González, F
    [J]. ANALYTICA CHIMICA ACTA, 2003, 481 (01) : 139 - 148