Microbial fuel cell operation on carbon monoxide: Cathode catalyst selection
被引:14
作者:
Neburchilov, V.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Inst Fuel Cell Innovat, Vancouver, BC V6T 1W5, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Neburchilov, V.
[2
]
Mehta, P.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Mehta, P.
[1
]
Hussain, A.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
McGill Univ, Dept Bioresource Engn, Ste Anne De Bellevue, PQ H9X 3V9, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Hussain, A.
[1
,3
]
Wang, H.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Inst Fuel Cell Innovat, Vancouver, BC V6T 1W5, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Wang, H.
[2
]
Guiot, S. R.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Guiot, S. R.
[1
]
Tartakovsky, B.
论文数: 0引用数: 0
h-index: 0
机构:
Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, CanadaNatl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
Tartakovsky, B.
[1
]
机构:
[1] Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H2P 2R2, Canada
[2] Natl Res Council Canada, Inst Fuel Cell Innovat, Vancouver, BC V6T 1W5, Canada
[3] McGill Univ, Dept Bioresource Engn, Ste Anne De Bellevue, PQ H9X 3V9, Canada
Electricity production from carbon monoxide (CO) in a microbial fuel cell (MFC) has recently been demonstrated. Efficient operation of this MFC requires a CO-tolerant and preferably inexpensive cathode. Pyrolised CoTMPP, FeTMPP, and Co/FeTMPP gas diffusion cathodes were tested in MFCs operated on acetate or CO. When the MFC was fed with acetate the best cathode performance was obtained when using a Co/FeTMPP (3:1) cathode with a Me catalyst load of 0.5 mg cm(-2), although this performance was slightly lower than that obtained with a cathode containing 0.5 mg-Pt cm(-2). Tests using a MFC operated on CO showed a higher power output when using the Co/FeTMPP cathode when compared both with CoTMPP and Pt cathodes. Crown Copyright (C) 2011, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
机构:
USA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USAUSA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USA
Chu, D
Jiang, RZ
论文数: 0引用数: 0
h-index: 0
机构:
USA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USAUSA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USA
机构:
USA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USAUSA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USA
Chu, D
Jiang, RZ
论文数: 0引用数: 0
h-index: 0
机构:
USA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USAUSA, Res Lab, Sensors & Electron Devices Directorate, Adelphi, MD 20783 USA