Passive design optimization of low energy buildings in different climates

被引:183
作者
Harkouss, Fatima [1 ,2 ]
Fardoun, Farouk [1 ]
Biwole, Pascal Henry [3 ,4 ]
机构
[1] Lebanese Univ, Dept GIM, Univ Inst Technol, Saida, Lebanon
[2] Univ Cote dAzur, JA Dieudonne Lab, UMR CNRS 7351, Parc Valrose, F-06108 Nice, France
[3] Univ Clermont Auvergne, CNRS, SIGMA Clermont, Inst Pascal, F-63000 Clermont Ferrand, France
[4] PSL Res Univ, MINES Paris Tech, PERSEE Ctr Proc Renewable Energies & Energy, CS 10207, F-06904 Sophia Antipolis, France
关键词
Building envelope; Passive cooling strategies; Optimization; Decision making; Climate; Life cycle cost; Adaptive thermal comfort; MULTIOBJECTIVE GENETIC ALGORITHM; ADAPTIVE THERMAL COMFORT; NET-ZERO; ELECTRE-III; RESIDENTIAL BUILDINGS; ENVELOPE DESIGN; EVOLUTIONARY ALGORITHM; DECISION-MAKING; NSGA-II; PERFORMANCE;
D O I
10.1016/j.energy.2018.09.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
Worldwide, the residential buildings are consuming a considerable amount of energy. The high potential of buildings towards energy efficiency has drawn special attention to the passive design parameters. A comprehensive study on optimal passive design for residential buildings is presented in this paper. Twenty-five different climates are simulated with the aim to produce best practices to reduce building energy demands (for cooling and heating) in addition to the life-cycle cost (LCC). The occupants' adaptive thermal comfort is also improved by implementing the appropriate passive cooling strategies such as blinds and natural ventilation. In this respect, the implemented methodology is composed of four phases: building energy simulation, optimization, Multi-criteria Decision Making (MCDM), sensitivity study, and finally an adaptive comfort analysis. An optimal passive solution of the studied building indicates the potential to save up to 54%, 87% and 52% of the cooling demands (Qcool), heating demands (Qheat) and LCC respectively with respect to the initial configuration. The obtained optimal passive parameters are validated with the National Renewable Energy Laboratory NREL benchmark for low energy building's envelope. Additionally, the integrated passive cooling strategies have demonstrated its competency since it leads to a significant overheating decrease. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:591 / 613
页数:23
相关论文
共 120 条
[1]   Cost-effective energy and carbon emission optimization in building renovation - A case-study in a low income neighbourhood [J].
Almeida, Manuela ;
Bencresciuto, Alessandro ;
Ferreira, Marco ;
Rodrigues, Ana .
6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 :2403-2408
[2]   A review on simulation-based optimization methods applied to building performance analysis [J].
Anh-Tuan Nguyen ;
Reiter, Sigrid ;
Rigo, Philippe .
APPLIED ENERGY, 2014, 113 :1043-1058
[3]  
[Anonymous], 2017, GLOBAL ELECT PRICE S
[4]  
[Anonymous], 2006, 15242 PREN
[5]  
[Anonymous], 2017, COMP EL PRIC MAJ N A
[6]  
[Anonymous], 2013, LIM THERM COMF AV OV
[7]  
[Anonymous], 2013, TRANSITION SUSTAINAB
[8]  
[Anonymous], 2011, IND LIGHT TECHN BACK
[9]  
[Anonymous], 2017, CO 2 EM STAT
[10]  
[Anonymous], 2006, 7730 NF EN ISO