Retrospective quality metrics review of stereotactic radiosurgery plans treating multiple targets using single-isocenter volumetric modulated arc therapy

被引:5
作者
Cui, Yunfeng [1 ]
Gao, Hao [2 ]
Zhang, Jiahan [1 ]
Kirkpatrick, John P. [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC 27708 USA
[2] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
normal brain V12Gy; plan quality; single-isocenter multi-target VMAT; BRAIN METASTASES; LINEAR-ACCELERATOR; RADIOTHERAPY; BREAST; LUNG;
D O I
10.1002/acm2.12869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To characterize key plan quality metrics in multi-target stereotactic radiosurgery (SRS) plans treated using single-isocenter volumetric modulated arc therapy (VMAT) in comparison to dynamic conformal arc (DCA) plans treating single target. To investigate the feasibility of quality improvement in VMAT planning based on previous planning knowledge. Materials and methods 97 VMAT plans of multi-target and 156 DCA plans of single-target treated in 2017 at a single institution were reviewed. A total of 605 targets were treated with these SRS plans. The prescription dose was normalized to 20 Gy in all plans for this analysis. Two plan quality metrics, target conformity index (CI) and normal tissue volume receiving more than 12 Gy (V12Gy), were calculated for each target. The distribution of V12Gy per target was plotted as a function of the target volume. For multi-target VMAT plans, the number of targets being treated in the same plan and the distance between targets were calculated to evaluate their impact on V12Gy. VMAT plans that had a large deviation of V12Gy from the average level were re-optimized to determine the possibility of reducing the variation of V12Gy in VMAT planning. Results Conformity index of multi-target VMAT plans were lower than that of DCA plans while the mean values of 12 Gy were comparable. The V12Gy for a target in VMAT plan did not show apparent dependence on the total number of targets or the distance between targets. The distribution of V12Gy exhibited a larger variation in VMAT plans compared to DCA plans. Re-optimization of outlier plans reduced V12 Gy by 33.9% and resulted in the V12Gy distribution in VMAT plans more closely resembling that of DCA plans. Conclusion The benchmark data on key plan quality metrics were established for single-isocenter multi-target SRS planning. It is feasible to use this knowledge to guide VMAT planning and reduce high V12Gy outliers.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 29 条
[1]   Institutional experience with SRS VMAT planning for multiple cranial metastases [J].
Ballangrud, Ase ;
Kuo, Li Cheng ;
Happersett, Laura ;
Lim, Seng Boh ;
Beal, Kathryn ;
Yamada, Yoshiya ;
Hunt, Margie ;
Mechalakos, James .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02) :176-183
[2]   Incidence proportions of brain metastases in patients diagnosed (1973 to 2001) in the metropolitan Detroit cancer surveillance system [J].
Barnholtz-Sloan, JS ;
Sloan, AE ;
Davis, FG ;
Vigneau, FD ;
Lai, P ;
Sawaya, RE .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (14) :2865-2872
[3]   IRRADIATED VOLUME AS A PREDICTOR OF BRAIN RADIONECROSIS AFTER LINEAR ACCELERATOR STEREOTACTIC RADIOSURGERY [J].
Blonigen, Brian J. ;
Steinmetz, Ryan D. ;
Levin, Linda ;
Lamba, Michael A. ;
Warnick, Ronald E. ;
Breneman, John C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (04) :996-1001
[4]   Effect of Radiosurgery Alone vs Radiosurgery With Whole Brain Radiation Therapy on Cognitive Function in Patients With 1 to 3 Brain Metastases A Randomized Clinical Trial [J].
Brown, Paul D. ;
Jaeckle, Kurt ;
Ballman, Karla V. ;
Farace, Elana ;
Cerhan, Jane H. ;
Anderson, S. Keith ;
Carrero, Xiomara W. ;
Barker, Fred G., II ;
Deming, Richard ;
Burri, Stuart H. ;
Menard, Cynthia ;
Chung, Caroline ;
Stieber, Volker W. ;
Pollock, Bruce E. ;
Galanis, Evanthia ;
Buckner, Jan C. ;
Asher, Anthony L. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (04) :401-409
[5]   Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy [J].
Clark, Grant M. ;
Popple, Richard A. ;
Prendergast, Brendan M. ;
Spencer, Sharon A. ;
Thomas, Evan M. ;
Stewart, John G. ;
Guthrie, Barton L. ;
Markert, James M. ;
Fiveash, John B. .
PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) :306-313
[6]   FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES [J].
Clark, Grant M. ;
Popple, Richard A. ;
Young, P. Edward ;
Fiveash, John B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01) :296-302
[7]   Stereotactic radiosurgery for multiple brain metastases: Results of multicenter benchmark planning studies [J].
Eaton, David J. ;
Lee, Jonathan ;
Paddick, Ian .
PRACTICAL RADIATION ONCOLOGY, 2018, 8 (04) :E212-E220
[8]   Comparative effectiveness of stereotactic radiosurgery versus whole-brain radiation therapy for patients with brain metastases from breast or non-small cell lung cancer [J].
Halasz, Lia M. ;
Uno, Hajime ;
Hughes, Melissa ;
D'Amico, Thomas ;
Dexter, Elisabeth U. ;
Edge, Stephen B. ;
Hayman, James A. ;
Niland, Joyce C. ;
Otterson, Gregory A. ;
Pisters, Katherine M. W. ;
Theriault, Richard ;
Weeks, Jane C. ;
Punglia, Rinaa S. .
CANCER, 2016, 122 (13) :2091-2100
[9]  
Hayat MA, 2014, BRAIN METASTASES FROM PRIMARY TUMORS, VOL 1: EPIDEMIOLOGY, BIOLOGY, AND THERAPY, pIX
[10]   Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study [J].
Iwai, Yoshio ;
Ozawa, Shuichi ;
Ageishi, Tatsuya ;
Pellegrini, Roberto ;
Yoda, Kiyoshi .
JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) :1015-1020