An evaluation of the signal and noise characteristics of four CCD-based film digitizers

被引:22
作者
Hangiandreou, NJ
O'Connor, TJ
Felmlee, JP
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Informat Serv, Rochester, MN 55905 USA
关键词
laser film digitizers; CCD film digitizers; quality control;
D O I
10.1118/1.598390
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Film digitizers are common devices in radiology departments involved with picture archive and communication systems (PACS) and teleradiology. In this paper, we studied the performance of film digitizers based on charge-coupled device detectors (CCD digitizers), and compared this with the performance of a laser digitizer (the de facto standard). Our focus was on the assessment of signal, noise and useful optical density range performance. A function (L*Delta D) derived from the Rose model was used to evaluate these parameters in absolute terms, based their predicted ability to detect objects of specific size and optical density difference with respect to background. We studied CCD digitizers from four different vendors and found that none was able to reliably operate up to the maximum density of 3.0 required to digitize plain radiographs, while the laser digitizer was capable of this task. Our analysis also indicated that two of the four CCD digitizers were adequate for digitizing laser-printed cross-sectional images in certain cases. Finally, our analysis indicated that digitization of SMPTE pattern films along with visual assessment of the 5% and 95% contrast patches was not sufficient for determining the utility of film digitizers for clinical tasks. Computation of the L*Delta D function provides a useful means of assessing the performance of film digitizers (e.g., for acceptance testing and quality control), and this technique may be adaptable for evaluation of other digital imaging modalities. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)01610-1].
引用
收藏
页码:2020 / 2026
页数:7
相关论文
共 10 条
[1]   TEST PATTERN FOR VIDEO DISPLAYS AND HARD-COPY CAMERAS [J].
GRAY, JE ;
LISK, KG ;
HADDICK, DH ;
HARSHBARGER, JH ;
OOSTERHOF, A ;
SCHWENKER, R .
RADIOLOGY, 1985, 154 (02) :519-527
[2]   A TEST PATTERN FOR QUALITY-CONTROL OF LASER SCANNER AND CHARGE-COUPLED-DEVICE FILM DIGITIZERS [J].
HALPERN, EJ .
JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) :3-9
[3]  
LIM AJ, 1996, RSNA CATEGORICAL COU, P183
[4]  
Lo S C, 1990, J Digit Imaging, V3, P119
[5]   TESTS FOR EVALUATING LASER FILM DIGITIZERS [J].
MEEDER, RJJ ;
JAFFRAY, DA ;
MUNRO, P .
MEDICAL PHYSICS, 1995, 22 (05) :635-642
[6]  
Rose A., 1973, Vision: human and electronic
[7]   IMAGE CALIBRATION OF LASER DIGITIZERS, PRINTERS, AND GRAY-SCALE DISPLAYS [J].
SIEGEL, EL ;
TEMPLETON, AW ;
COOK, LT ;
ECKARD, DA ;
HARRISON, LA ;
DWYER, SJ .
RADIOGRAPHICS, 1992, 12 (02) :329-335
[8]  
TRUEBLOOD JH, 1993, DIGITAL IMAGING
[9]   Assessing contrast on MR images [J].
Wolff, SD ;
Balaban, RS .
RADIOLOGY, 1997, 202 (01) :25-29
[10]   EVALUATION OF IMAGING PROPERTIES OF A LASER FILM DIGITIZER [J].
YIN, FF ;
GIGER, ML ;
DOI, K ;
YOSHIMURA, H ;
XU, XW ;
NISHIKAWA, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :273-280