Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma

被引:59
|
作者
Mulkens, T. H.
Marchal, P.
Daineffe, S.
Salgado, R.
Bellinck, P.
te Rijdt, B.
Kegelaers, B.
Termote, J-L
机构
[1] Heilig Hart Ziekenhuis, Dept Radiol, B-2500 Lier, Belgium
[2] Heilig Hart Ziekenhuis, Dept Neurosurg, B-2500 Lier, Belgium
关键词
D O I
10.3174/ajnr.A0608
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The purpose of this work was to evaluate the possible use of low-dose multidetector CT WDCT) in cervical clearance of patients with blunt trauma. MATERIALS AND METHODS: A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose In = 51) and low-dose MDCT with tube current modulation at high In = 70) and low In = 70) tube voltage (kilovolts). Effective dose, image noise, and subjective image quality were calculated in all of the patients. RESULTS: MDCT found 18 patients (9.4%) with a cervical spine fracture, 3 in the standard-dose and 15 in the low-dose group, 14 of them with unstable lesions, Tube current modulation reduced the dose by 50%-61 % in all of the low-dose examinations. The mean effective dose was 3.75,1.57, and 1.08 mSv, and mean image noise was 14.82, 17.46, and 19.72 Hounsfield units for standard dose and low dose with high and low kilovolt examinations, respectively. These differences in mean effective dose and image noise were significant between the 3 examination groups (Kruskal-Wallis test: P <.0001 and P =.0001). Evaluation of subjective image quality by 2 radiologists and 2 residents showed no significant difference in image quality score among the 3 examination groups (Kruskal-Wallis tests, P =.61,.32,.18, and.31). All of the reviewers correctly detected 18 fractures, except 1 resident, who missed 3 fractures. CONCLUSION: Low-dose cervical spine MDCT in patients with blunt trauma gives a substantial dose reduction of 61 %-71 %, compared with standard-dose MDCT, with a small increase in image noise and without difference in subjective image quality evaluation.
引用
收藏
页码:1444 / 1450
页数:7
相关论文
共 50 条
  • [31] Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules
    Liu, Jieke
    Xu, Hao
    Qing, Haomiao
    Li, Yong
    Yang, Xi
    He, Changjiu
    Ren, Jing
    Zhou, Peng
    FRONTIERS IN ONCOLOGY, 2021, 10
  • [32] CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT (vol 81, pg 2860, 2012)
    Christe, Andreas
    Lin, Margaret C.
    Yen, Andrew C.
    Hallett, Rich L.
    Roychoudhury, Kingshuk
    Schmitzberger, Florian
    Fleischmann, Dominik
    Leung, Ann N.
    Rubin, Geoffrey D.
    Vock, Peter
    Roos, Justus E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : 2067 - 2067
  • [33] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [34] Comparison of standard-dose and low-dose gemcitabine regimens in pancreatic adenocarcinoma patients: a prospective randomized trial
    Sakamoto, H
    Kitano, M
    Suetomi, Y
    Takeyama, Y
    Ohyanagi, H
    Nakai, T
    Yasuda, C
    Kudo, M
    JOURNAL OF GASTROENTEROLOGY, 2006, 41 (01) : 70 - 76
  • [35] Update of Comparison of Low-Dose and Standard-Dose Total Skin Electron Beam Therapy for Mycosis Fungoides
    Dault, J.
    Zhao, S.
    Slade, A. N.
    Song, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E213 - E213
  • [36] Comparison of standard-dose and low-dose gemcitabine regimens in pancreatic adenocarcinoma patients: a prospective randomized trial
    Hiroki Sakamoto
    Masayuki Kitano
    Yoichirou Suetomi
    Yoshifumi Takeyama
    Harumasa Ohyanagi
    Takuya Nakai
    Chikao Yasuda
    Masatoshi Kudo
    Journal of Gastroenterology, 2006, 41 : 70 - 76
  • [37] Standard-dose versus low-dose multidetector computed tomography examinations in patients with uncontrolled chronic rhinosinusitis A randomized, controlled trial
    Huang, Wei
    Ye, Jian
    Guan, Xinli
    MEDICINE, 2018, 97 (50)
  • [38] A comparison of low-dose and standard-dose oral estrogen on forearm endothelial function in early postmenopausal women
    Sanada, M
    Higashi, Y
    Nakagawa, K
    Tsuda, M
    Kodama, I
    Kimura, M
    Chayama, K
    Ohama, K
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2003, 88 (03): : 1303 - 1309
  • [39] Low-Dose versus Standard-Dose Intravenous Alteplase in Acute Ischemic Stroke
    Anderson, C. S.
    Robinson, T.
    Lindley, R. I.
    Arima, H.
    Lavados, P. M.
    Lee, T. -H.
    Broderick, J. P.
    Chen, X.
    Chen, G.
    Sharma, V. K.
    Kim, J. S.
    Thang, N. H.
    Cao, Y.
    Parsons, M. W.
    Levi, C.
    Huang, Y.
    Olavarria, V. V.
    Demchuk, A. M.
    Bath, P. M.
    Donnan, G. A.
    Martins, S.
    Pontes-Neto, O. M.
    Silva, F.
    Ricci, S.
    Roffe, C.
    Pandian, J.
    Billot, L.
    Woodward, M.
    Li, Q.
    Wang, X.
    Wang, J.
    Chalmers, J.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (24): : 2313 - 2323
  • [40] Pulmonary nodules detection with ultralow dose, low dose and standard dose multidetector CT
    Kadota, M
    Yamashita, Y
    Nakayama, M
    Nakayama, Y
    Nishi, J
    Takahashi, M
    RADIOLOGY, 2000, 217 : 128 - 129