Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma

被引:59
|
作者
Mulkens, T. H.
Marchal, P.
Daineffe, S.
Salgado, R.
Bellinck, P.
te Rijdt, B.
Kegelaers, B.
Termote, J-L
机构
[1] Heilig Hart Ziekenhuis, Dept Radiol, B-2500 Lier, Belgium
[2] Heilig Hart Ziekenhuis, Dept Neurosurg, B-2500 Lier, Belgium
关键词
D O I
10.3174/ajnr.A0608
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The purpose of this work was to evaluate the possible use of low-dose multidetector CT WDCT) in cervical clearance of patients with blunt trauma. MATERIALS AND METHODS: A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose In = 51) and low-dose MDCT with tube current modulation at high In = 70) and low In = 70) tube voltage (kilovolts). Effective dose, image noise, and subjective image quality were calculated in all of the patients. RESULTS: MDCT found 18 patients (9.4%) with a cervical spine fracture, 3 in the standard-dose and 15 in the low-dose group, 14 of them with unstable lesions, Tube current modulation reduced the dose by 50%-61 % in all of the low-dose examinations. The mean effective dose was 3.75,1.57, and 1.08 mSv, and mean image noise was 14.82, 17.46, and 19.72 Hounsfield units for standard dose and low dose with high and low kilovolt examinations, respectively. These differences in mean effective dose and image noise were significant between the 3 examination groups (Kruskal-Wallis test: P <.0001 and P =.0001). Evaluation of subjective image quality by 2 radiologists and 2 residents showed no significant difference in image quality score among the 3 examination groups (Kruskal-Wallis tests, P =.61,.32,.18, and.31). All of the reviewers correctly detected 18 fractures, except 1 resident, who missed 3 fractures. CONCLUSION: Low-dose cervical spine MDCT in patients with blunt trauma gives a substantial dose reduction of 61 %-71 %, compared with standard-dose MDCT, with a small increase in image noise and without difference in subjective image quality evaluation.
引用
收藏
页码:1444 / 1450
页数:7
相关论文
共 50 条
  • [1] Radiation Dose Reduction in Cervical Spine Computed Tomography in Cervical Spine Trauma: Comparison of Low-dose with Standard-dose Multidetector Computed Tomography
    Man, K. Y.
    Mo, K. M.
    Sung, H. T.
    Cho, K. Y.
    Tam, C. W.
    HONG KONG JOURNAL OF RADIOLOGY, 2019, 22 (03): : 180 - 187
  • [2] Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis
    Tack, D
    Widelec, J
    De Maertelaer, V
    Bailly, JM
    Delcour, C
    Gevenois, PA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 939 - 944
  • [3] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Nevzat Karabulut
    Mustafa Törü
    Veli Gelebek
    Meltem Gülsün
    Macit O. Ariyürek
    European Radiology, 2002, 12 : 2764 - 2769
  • [4] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Karabulut, N
    Törü, M
    Gelebek, V
    Gülsün, M
    Ariyurek, OM
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2764 - 2769
  • [5] Multidetector CT in patients suspected of having lumbar disk herniation: Comparison of standard-dose and simulated low-dose techniques
    Bohy, Pascale
    de Maertelaer, Viviane
    Roquigny, Aymeric
    Keyzer, Caroline
    Tack, Denis
    Gevenois, Pierre Alain
    RADIOLOGY, 2007, 244 (02) : 524 - 531
  • [6] CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT
    Christe, Andreas
    Lin, Margaret C.
    Yen, Andrew C.
    Hallett, Rich L.
    Roychoudhury, Kingshuk
    Schmitzberger, Florian
    Fleischmann, Dominik
    Leung, Ann N.
    Rubin, Geoffry D.
    Vock, Peter
    Roos, Justus E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2860 - 2866
  • [7] Diagnostic usefulness of low-dose lumbar multi-detector CT with iterative reconstruction in trauma patients: a comparison with standard-dose CT
    Lee, Sun Hwa
    Yun, Seong Jong
    Kim, Dong Hyeon
    Jo, Hyeon Hwan
    Song, Jae Gwang
    Park, Yong Sung
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1077):
  • [8] Low-dose versus standard-dose normal temporal bone CT in children: a comparison study
    Rashma, R.
    Kumar, Jyoti
    Garg, Anju
    Batra, Radhika
    Meher, Ravi
    Phulia, Ankita
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [9] Comparison of low-dose and standard-dose multirow detector helical CT of the sinuses and computer simulation of effective dose
    Tack, DM
    Widelec, J
    Bailly, J
    Delcour, CP
    RADIOLOGY, 2001, 221 : 620 - 620
  • [10] A detection system for low-dose and standard-dose CT-colonography (CTC)
    Agliozzo, S.
    Baggio, R.
    Bert, A.
    Boda, P.
    Campanella, D.
    Dmitriev, I.