Potential effects of inhaler mouthpiece size on particle deposition in the human upper airway

被引:9
作者
Cai, Xinyu [1 ]
Ma, Bingjie [1 ]
Kourmatzis, Agisilaos [2 ]
Salehi, Fatemeh [1 ]
Lee, Ann [1 ]
Farina, Dino [3 ]
Chan, Kim [4 ]
Cheng, Shaokoon [1 ]
机构
[1] Macquarie Univ, Fac Sci & Engn, Sch Engn, Macquarie Pk, NSW 2109, Australia
[2] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Sydney, NSW, Australia
[3] Proveris Sci Corp, Hudson, MA USA
[4] Univ Sydney, Fac Med & Hlth, Sydney Pharm Sch, Adv Drug Delivery Grp, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
Jonathan P; Reid; INHALATION FLOW-RATE; AEROSOL DEPOSITION; DEVICE RESISTANCE; REALISTIC MODEL; TRANSPORT; DIAMETER; GEOMETRY; DELIVERY; CAST; MRI;
D O I
10.1080/02786826.2022.2086034
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Understanding the impact of inhaler mouthpiece sizes on particle transport and deposition in the human upper airway is important to optimize inhaler designs toward improving the therapeutic efficacy of inhaled drug delivery. This study demonstrates the potential effects of inhaler mouthpiece size on particle deposition in the human pharynx. MRI scans of two healthy human volunteers using a small and a large inhaler mouthpiece mockup were acquired. Four 3 D models of the pharynx were reconstructed from the MRI images, and CFD simulations using discrete phase modeling and polydisperse particles (MMD: 6.96 mu m, span: 1.38 mu m) were performed using two different transient flow profiles to investigate particle deposition with different peak flow rates. The results showed that particle deposition in the pharynx associated with a large mouthpiece and low peak flow rate (27 L/min) is more than 80% in one of the subjects, which is a onefold higher compared to when the subject was with the small inhaler mouthpiece. The cases with a small inhaler mouthpiece and high peak flow rate (85 L/min) have the least number of particles deposited in the upper airways of both subjects. The use of large inhaler mouthpiece results in an erratic distribution of particles deposition, with a higher concentration of particles in the oral cavity, not observed with the small inhaler mouthpiece. The results from this work provide further evidence to existing literature that inhaler mouthpiece size matters and that it produces intra and inter-individual variations in drug particle deposition characteristics in the human upper airway. Copyright (c) 2021 American Association for Aerosol Research
引用
收藏
页码:802 / 818
页数:17
相关论文
共 48 条
  • [1] Assessing the relationship between movement and airflow in the upper airway using computational fluid dynamics with motion determined from magnetic resonance imaging
    Bates, Alister J.
    Schuh, Andreas
    Amine-Eddine, Gabriel
    McConnell, Keith
    Loew, Wolfgang
    Fleck, Robert J.
    Woods, Jason C.
    Dumoulin, Charles L.
    Amin, Raouf S.
    [J]. CLINICAL BIOMECHANICS, 2019, 66 : 88 - 96
  • [2] Studies of the human oropharyngeal airspaces using magnetic resonance imaging IV -: The oropharyngeal retention effect for four inhalation delivery systems
    Burnell, Patricia K. P.
    Asking, Lars
    Borgstrom, Lars
    Nichols, Steve C.
    Olsson, Bo
    Prime, David
    Shrubb, Ian
    [J]. JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2007, 20 (03): : 269 - 281
  • [3] Tracheal and central bronchial aerodynamics using virtual bronchoscopy and computational fluid dynamics
    Cebral, JR
    Summers, RM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (08) : 1021 - 1033
  • [4] Does upper airway deformation affect drug deposition?
    Cheng, Shaokoon
    Kourmatzis, Agisilaos
    Mekonnen, Taye
    Gholizadeh, Hanieh
    Raco, Joel
    Chen, Lan
    Tang, Patricia
    Chan, Hak-Kim
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 572
  • [5] Healthy humans with a narrow upper airway maintain patency during quiet breathing by dilating the airway during inspiration
    Cheng, Shaokoon
    Brown, Elizabeth C.
    Hatt, Alice
    Butler, Jane E.
    Gandevia, Simon C.
    Bilston, Lynne E.
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2014, 592 (21): : 4763 - 4774
  • [6] Aerosol deposition in the extrathoracic region
    Cheng, YS
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2003, 37 (08) : 659 - 671
  • [7] Particle deposition in a cast of human oral airways
    Cheng, YS
    Zhou, Y
    Chen, BT
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1999, 31 (04) : 286 - 300
  • [8] Deposition of Particles in Human Mouth-Throat Replicas and a USP Induction Port
    Cheng, Yung Sung
    Zhou, Yue
    Su, Wei-Chung
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : 147 - 155
  • [9] The Confusing World of Dry Powder Inhalers: It Is All About Inspiratory Pressures, Not Inspiratory Flow Rates
    Clark, Andrew R.
    Weers, Jeffry G.
    Dhand, Rajiv
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2020, 33 (01) : 1 - 11
  • [10] Predicting extrathoracic deposition from dry powder inhalers
    DeHaan, WH
    Finlay, WH
    [J]. JOURNAL OF AEROSOL SCIENCE, 2004, 35 (03) : 309 - 331