Near-infrared reflection at 780 nm for detection of early proximal caries in posterior permanent teeth in vitro

被引:7
作者
Heck, Katrin [1 ]
Litzenburger, Friederike [1 ]
Geitl, Thomas [1 ]
Kunzelmann, Karl-Heinz [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodontol, Munich, Germany
关键词
Dental caries; Diagnostic Imaging; Near-infrared light; X-ray microtomography; Sensitivity and specificity; LIGHT-SCATTERING; DENTAL ENAMEL; TRANSILLUMINATION; AGREEMENT; DIAGNOSIS;
D O I
10.1259/dmfr.20210005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this in vitro study was to evaluate the diagnostic potential of near-infrared reflection at 780 nm (NIRR780nm) for early proximal caries detection on the occlusal, buccal and oral surfaces of molars and premolars under simulated, clinically relevant conditions. The findings were validated by micro-computed tomography (mu CT). Methods: Bitewing radiography (BWR) was used as a comparative diagnostic method. 250 sound or decayed permanent teeth were examined using NIRR780nm and BWR. The NIRR780nm findings were evaluated using yes/no decisions depending on the presence of caries lesions, as the enamel-dentin junction was not detectable in the majority of samples. All NIRR780nm, BWR and mu CT findings were obtained twice by two trained examiners. NIRR780nm images were evaluated both occlusally alone and combined occlusally, lingually and buccally. All findings were presented in a cross-table. Sensitivity, specificity and area under the curve (AUC) values were calculated. Reliability assessment was performed using. statistics. Results: Underestimation of caries was observed for NIRR780nm in 26.0% of all surfaces and for BWR in 32.8% of all surfaces. Overestimation was 10.0% for NIRR780nm and 0.4% for BWR. Trilateral NIRR780nm assessment exhibited an overall accuracy of 67.2 %, an underestimation of 13.6% and an overestimation of 19.2%. Trilateral NIRR780nm exhibited 63.0% sensitivity and 69.6% specificity, while BWR exhibited 26.7% sensitivity but 100% specificity for proximal caries detection. Conclusion: NIRR780nm is not suitable for reliable detection of early proximal caries, even with the application of an ideal setup and optimized in vitro conditions.
引用
收藏
页数:11
相关论文
共 46 条
[1]  
AbdeIaziz M, 2015, INT J ESTHET DENT, V10, P158
[2]   Near infrared transillumination compared with radiography to detect and monitor proximal caries: A clinical retrospective study [J].
Abdelaziz, Marwa ;
Krejci, Ivo ;
Perneger, Thomas ;
Feilzer, Albert ;
Vazquez, Lydia .
JOURNAL OF DENTISTRY, 2018, 70 :40-45
[3]   Influence of stains on lesion contrast in the pits and fissures of tooth occlusal surfaces from 800-1600-nm [J].
Almaz, Elias C. ;
Simon, Jacob C. ;
Fried, Daniel ;
Darling, Cynthia L. .
LASERS IN DENTISTRY XXII, 2016, 9692
[4]  
[Anonymous], 2012, IMAGEJ I O UTILITIES
[5]  
Banting D., 2005, Ann Arbor, V1001, P48109
[6]   Polarized versus nonpolarized digital images for the measurement of demineralization surrounding orthodontic brackets [J].
Benson, Philip Edward ;
Shah, Anwar Ali ;
Willmot, Derrick Robert .
ANGLE ORTHODONTIST, 2008, 78 (02) :288-293
[7]   Comparison of micro-CT imaging and histology for approximal caries detection [J].
Boca, C. ;
Truyen, B. ;
Henin, L. ;
Schulte, A. G. ;
Stachniss, V. ;
De Clerck, N. ;
Cornelis, J. ;
Bottenberg, P. .
SCIENTIFIC REPORTS, 2017, 7
[9]   Light scattering properties of natural and artificially demineralized dental enamel at 1310 nm [J].
Darling, Cynthia L. ;
Huynh, Gigi D. ;
Fried, Daniel .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (03)
[10]  
DIN Deutsches Institut fur Normung e.V. Normenausschuss Radiologie (NAR), 2014, SICH BILDQ RONT 157