Optimisation of flow-injection-hydride generation inductively coupled plasma spectrometric determination of selenium in electrolytic manganese

被引:13
作者
Etxebarria, N
Antolín, R
Borge, G
Posada, T
Raposo, JC
机构
[1] Euskal Herriko Unibertsitatea, Klin Analitikoaren Saila, E-48080 Bilbao, Spain
[2] Bostlan SA, Poligono Ind Trobika, E-48100 Mungia, Spain
关键词
selenium determination; electrolytic manganese; hydride generation; inductively coupled plasma; variables optimisation; aluminium alloying;
D O I
10.1016/j.talanta.2004.08.059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow-injection-hydride generation procedure for Se in electrolytic manganese was optimized by means of the experimental design approach. Instrumental variables like power Supplied (P), sample (F) and argon (G) flow rates together with chemical variables like NaBH4 and HCl concentrations were studied. In case of the chemical variables, it was concluded that sodium tetrahydridoborate concentrations higher than 1.0% extinguished the plasma while HCl concentration should always be higher than 0.6 mol dm(-3) The analysis of effects suggested that all the instrumental variables are significant factors, and the optimum conditions were P = 1550 W, F = 4.75 mL min(-1) and G = 0.6 mL min(-1). The influence of Mn was specially Studied and it was Concluded that the interferences were negligible if Mn is below 2.0 2 L-1. In the same sense, the interferences of antimony(Ill), arsenic(V) and mercury(II) were also considered negligible. Finally, a detection limit of 0.0005% (w/w) was obtained (a repeatability R.S.D. < 2.0% for all Se concentrations tried). Some manganese samples were also spiked with different concentrations of Se(IV) and the results demonstrated to be in good statistical agreement with expected values. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1209 / 1214
页数:6
相关论文
共 22 条
[1]  
Aboutalebi MR, 2003, LIGHT MET, P787
[2]  
[Anonymous], 1964, STABILITY CONSTANTS
[3]  
Boumans P.W. J. M., 1987, INDUCTIVELY COUPLED
[4]   Identification of volatile selenium compounds produced in the hydride generation system from organoselenium compounds [J].
Chatterjee, A ;
Shibata, Y ;
Yoneda, M ;
Banerjee, R ;
Uchida, M ;
Kon, H ;
Morita, M .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3181-3186
[5]   Automated determination of tin and nickel in brass by on-line anodic electrodissolution and electrothermal atomic absorption spectrometry [J].
da Silva, JBB ;
Giacomelli, MBO ;
de Souza, IG ;
Curtius, AJ .
TALANTA, 1998, 47 (05) :1191-1198
[6]  
DAVIES L, 1993, EFFECICIENCY RES DEV
[7]  
Dedina J., 1995, HYDRIDE GENERATION A, V1st
[8]   Plants, selenium and human health [J].
Ellis, DR ;
Salt, DE .
CURRENT OPINION IN PLANT BIOLOGY, 2003, 6 (03) :273-279
[9]  
ESBENSEN KH, 1994, MUTLIVARIATE DATA AN
[10]  
HAGELSTEIN K, 2003, JOM, P51