The MiniACcor:: Constructive redesign of an implantable total artificial heart, initial laboratory testing and further steps

被引:7
作者
Kwant, P. B.
Finocchiaro, T.
Foerster, F.
Reul, H.
Rau, G.
Morshuis, M.
El Banayosi, A.
Koerfer, R.
Schmitz-Rode, T.
Steinseifer, U.
机构
[1] Helmholtz Eye Dis Res Inst, Chair Appl Med Engn, D-52074 Aachen, Germany
[2] Heart & Diabet Ctr N Rhine Westphalia, Bad Oeynhausen, Germany
关键词
ACcor; MiniACcor; total artificial heart; redesign; laboratory testing; compliance chamber;
D O I
10.1177/039139880703000411
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Aachen Total Artificial Heart (ACcor) has been under development at the Helmholtz Institute in Aachen over the last decade. It may serve as a bridge to transplant or as a long-term replacement of the natural heart. Based upon previous in vivo experiments with the ACcor total artificial heart, it was decided to optimize and redesign the pump unit. Smaller dimensions, passive filling and separability into three components were the three main design goals. The new design is called the MiniACcor, which is about 20% smaller than its predecessor, and weighs only 470 grams. Also its external driver/control unit was miniaturized and a new microcontroller was selected. To validate the design, it was extensively tested in laboratory mock loops. The MiniACcor was able to pump between 4.5 and 7 1/min at different pump rates against normal physiological pressures. Several requirements for the future compliance chamber and transcutaneous energy transmission (TET) system were also measured in the same mock loop. Further optimization and validation are being performed in cooperation with the Heart and Diabetes Centre North Rhine-Westphalia.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 16 条
[1]   Development of the undulation pump total artificial heart [J].
Abe, Y ;
Chinzei, T ;
Isoyama, T ;
Ono, T ;
Mochizuki, S ;
Mabuchi, K ;
Baba, K ;
Matsuura, H ;
Sun, YP ;
Kouno, A ;
Atsumi, K ;
Fujimasa, I ;
Imachi, K .
ARTIFICIAL ORGANS, 1997, 21 (07) :665-669
[2]   Total artificial heart bridge to transplantation: A 9-year experience with 62 patients [J].
Copeland, JG ;
Smith, RG ;
Arabia, FA ;
Nolan, PE ;
McClellan, D ;
Tsau, PH ;
Sethi, GK ;
Bose, RK ;
Banchy, ME ;
Covington, DL ;
Slepian, MJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (07) :823-831
[3]   In vivo studies of the MagScrew total artificial heart in calves [J].
Doi, K ;
Smith, WA ;
Harasaki, H ;
Takagaki, M ;
Ochiai, Y ;
Howard, MW ;
Weber, S ;
Byerman, BP ;
Massiello, AL ;
Vitale, N ;
Donahue, A ;
Hirschman, G ;
Fukamachi, K .
ASAIO JOURNAL, 2002, 48 (03) :222-225
[4]   Initial experience with the AbioCor Implantable Replacement Heart System [J].
Dowling, RD ;
Gray, LA ;
Etoch, SW ;
Laks, H ;
Marelli, D ;
Samuels, L ;
Entwistle, J ;
Couper, G ;
Vlahakes, GJ ;
Frazier, OH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (01) :131-141
[5]   CardioWest total artificial heart: Bad oeynhausen experience [J].
El-Banayosy, A ;
Arusoglu, L ;
Morshuis, M ;
Kizner, L ;
Tenderich, G ;
Sarnowski, P ;
Milting, H ;
Koerfer, R .
ANNALS OF THORACIC SURGERY, 2005, 80 (02) :548-552
[6]   The total artificial heart: Where we stand [J].
Frazier, OH ;
Dowling, RD ;
Gray, LA ;
Shah, NA ;
Pool, T ;
Gregoric, I .
CARDIOLOGY, 2004, 101 (1-3) :117-121
[7]   THE HELMHOLTZ TOTAL ARTIFICIAL-HEART LABTYPE [J].
KAUFMANN, R ;
REUL, H ;
RAU, G .
ARTIFICIAL ORGANS, 1994, 18 (07) :537-542
[8]   ELECTROMECHANICAL ARTIFICIAL-HEART WITH A NEW GEAR TYPE AND ANGLED PUMP CHAMBERS [J].
KAUFMANN, R ;
REUL, H ;
RAU, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (08) :481-487
[9]   FUZZY CONTROL CONCEPT FOR A TOTAL ARTIFICIAL-HEART [J].
KAUFMANN, R ;
BECKER, K ;
NIX, C ;
REUL, H ;
RAU, G .
ARTIFICIAL ORGANS, 1995, 19 (04) :355-361
[10]  
Kaufmann R, 1997, ARTIF ORGANS, V21, P131