Prospective Randomized Comparative Evaluation of Proximal Valve Polyurethane and Distal Valve Silicone Peripherally Inserted Central Catheters

被引:49
作者
Ong, Cheng K. [1 ]
Venkatesh, Sudhakar K. [1 ]
Lau, Gabriel B. [2 ]
Wang, Shih C. [3 ]
机构
[1] Natl Univ Singapore, Dept Diagnost Imaging, Natl Univ Hlth Syst, Yong Loo Lin Sch Med, Singapore 119074, Singapore
[2] Dunedin Publ Hosp, Dept Radiol, Dunedin, New Zealand
[3] Westmead Hosp, Dept Radiol, Westmead, NSW 2145, Australia
关键词
CENTRAL VENOUS CATHETERS; BLOOD-STREAM INFECTION; RISK; PREVENTION; ACCESS; COMPLICATIONS; GUIDELINES; MANAGEMENT; PLACEMENT; NUTRITION;
D O I
10.1016/j.jvir.2010.04.020
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The objective of this study was to evaluate and compare the relative durability and complications between the proximal valve polyurethane and distal valve silicone peripherally inserted central catheters (PICCs). METHODS: Institutional review board approval was obtained. A total of 326 patients (mean age, 50.4 years) was assigned randomly to receive either a proximal valve polyurethane PICC (n = 198) or a distal valve silicone Groshong PICC (n = 194). All PICCs were inserted under radiologic guidance by interventional radiologists. Follow-up data were collected until catheter removal because of complications or treatment completion. RESULTS: The mean catheter dwell time was 25.6 days (range, 1-245 days). Complications were encountered in 26.8% and 47.9% of the proximal valve polyurethane PICCs and distal valve silicone PICCs, respectively (P < .001). Significantly higher incidences of phlebitis (23.2% versus 11.6%, P = .003) and catheter-related infection (6.2% versus 2%, P = 0.043) were noted in the distal valve silicone PICCs. No significant differences in the incidence of catheter occlusion, fracture, or dislodgement were found. Multivariate logistic regression analysis showed a higher complication rate in the distal valve silicone PICCs corrected for patients' age, sex, underlying morbidity, indication, peripheral vein accessed, arm used, catheter tip placement, and the number of venepunctures attempted. CONCLUSIONS: Proximal valve polyurethane PICCs were more durable than distal valve silicone PICCs, which were associated with a higher incidence of phlebitis and infection, probably related to the materials of the catheters and the designs and placements of the catheter valves..
引用
收藏
页码:1191 / 1196
页数:6
相关论文
共 27 条
[1]   Incidence of upper limb venous thrombosis associated with peripherally inserted central catheters (PICC) [J].
Abdullah, JJ ;
Mohammad, N ;
Sangkar, JV ;
Aziz, YFA ;
Gan, GG ;
Goh, KY ;
Benedict, I .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (931) :596-600
[2]   Venous thrombosis associated with the placement of peripherally inserted central catheters [J].
Allen, AW ;
Megargell, JL ;
Lynch, FC ;
Singh, H ;
Singh, Y ;
Waybill, PN .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) :1309-1314
[3]   Prevention of Staphylococcus aureus biofilm on dialysis catheters and adherence to human cells [J].
Balaban, N ;
Gov, Y ;
Bitler, A ;
Boelaert, JR .
KIDNEY INTERNATIONAL, 2003, 63 (01) :340-345
[4]  
Chlebicki M. P., 2003, SMJ Singapore Medical Journal, V44, P531
[5]   Efficacy and complications in peripherally inserted central catheter insertion: A study using 4-Fr non-valved catheters and a single infusate [J].
Chu, F. S. K. ;
Cheng, V. C. C. ;
Law, M. W. M. ;
Tso, W. K. .
AUSTRALASIAN RADIOLOGY, 2007, 51 (05) :453-457
[6]   Tip position of long-term central venous access devices used for parenteral nutrition [J].
DeChicco, Robert ;
Seidner, Douglas L. ;
Brun, Carlos ;
Steiger, Ezra ;
Stafford, Judy ;
Lopez, Rocio .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2007, 31 (05) :382-387
[7]   Peripherally inserted central catheters: Outcome as a function of the operator [J].
Fong, NI ;
Holtzman, SR ;
Bettmann, MA ;
Bettis, SJ .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :723-729
[8]  
Hinson E K, 1996, J Intraven Nurs, V19, P198
[9]   Prospective randomized comparison of valved versus nonvalved peripherally inserted central vein catheters [J].
Hoffer, EK ;
Borsa, J ;
Santulli, P ;
Bloch, R ;
Fontaine, AB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) :1393-1398
[10]   Peripherally inserted central catheters with distal versus proximal valves: Prospective randomized trial [J].
Hoffer, EK ;
Bloch, RD ;
Borsa, JJ ;
Santulli, P ;
Fontaine, AB ;
Francoeur, N .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (10) :1173-1177