Miniature time-of-flight mass spectrometer

被引:3
|
作者
McLoughlin, MP [1 ]
Anderson, CW [1 ]
Bryden, WA [1 ]
Carlson, MA [1 ]
Ecelberger, SA [1 ]
Ko, HW [1 ]
机构
[1] Johns Hopkins Univ, Appl Phys Lab, Laurel, MD 20723 USA
来源
BIOMEDICAL SENSING AND IMAGING TECHNOLOGIES, PROCEEDINGS OF | 1998年 / 3253卷
关键词
mass spectrometry; time of flight; biomedical; biological;
D O I
10.1117/12.308045
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Johns Hopkins University Applied Physics Laboratory (JHU/APL) is designing, fabricating and testing a small, high resolution, time-of-flight mass spectrometer (TOFMS) suitable for biomedical applications requiring lightweight, low-powered and portable instrumentation. This instrument can be used to identify solids, liquids and gases of both chemical and biological origins to quantify the habitat environment and support biomedical research and medical care. The virtue of the JHU/APL TOFMS technology presented here, resides in the promise for a small (less than one cubic ft.), lightweight (less than 5 kg), low power (less than 50 watts), device that can be used continuously with advanced signal processing diagnostics. To date, JHU/APL has demonstrated mass capability beyond 10,000 Atomic Mass Units (AMU) in a very small, low power prototype for biological analysis. The JHU/APL approach, described in this paper, is to design the instrument for both wide mass range and fine mass resolution by the use of electronic control in a tandem mass spectrometer instrument. In this paper we will outline the principle behind the operation of the APL's miniaturized TOFMS system and present examples of the analysis of chemical and biological substances. In addition, we will also describe a novel method for the collection of airborne particles for TOFMS analysis suitable for automated collection and analysis applications.
引用
收藏
页码:155 / 164
页数:10
相关论文
共 50 条
  • [31] MARS: Inverted time-of-flight backscattering spectrometer at SINQ
    Allenspach, P
    PHYSICA B, 2000, 276 : 166 - 167
  • [32] Time-of-flight mass spectrometry of very exotic systems
    Meisel, Z.
    George, S.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 145 - 150
  • [33] Upgrade of the INS cold neutron time-of-flight spectrometer
    Schober, H
    Dianoux, AJ
    Cook, JC
    Mezei, F
    PHYSICA B, 2000, 276 : 164 - 165
  • [34] Towards polarization analysis on a thermal time-of-flight spectrometer
    Stride, JA
    Andersen, KH
    Murani, AP
    Mutka, H
    Schober, H
    Stewart, JR
    PHYSICA B-CONDENSED MATTER, 2005, 356 (1-4) : 146 - 149
  • [35] Time-of-flight spectrometer FOCUS at SINQ: first results
    Janssen, S
    Altorfer, F
    Holitzner, L
    Hempelmann, R
    PHYSICA B, 2000, 276 : 89 - 90
  • [36] Background optimization for the neutron time-of-flight spectrometer NEAT
    Gunther, G.
    Russina, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 250 - 261
  • [37] A new electrospray-ionization time-of-flight mass spectrometer with electrostatic wire ion guide
    Bondarenko, PV
    Macfarlane, RD
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 160 (1-3): : 241 - 258
  • [38] Time-of-flight (TOF) mass spectrometer without pulses of any kind, with continuous ion introduction
    Hars, G
    Maros, I
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 225 (02) : 101 - 114
  • [39] Development of a novel dual time-of-flight imaging mass spectrometer: Principal, realization, and optimal performance
    Shuttleworth, I. G.
    SURFACE REVIEW AND LETTERS, 2008, 15 (04) : 369 - 389
  • [40] A multi-reflection time-of-flight mass spectrometer for the offline ion source of the PUMA experiment
    Schlaich, M.
    Fischer, J.
    Fischer, P.
    Klink, C.
    Obertelli, A.
    Schmidt, A.
    Schweikhard, L.
    Wienholtz, F.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 495