摘要
Purpose: To prospectively investigate computed tomographic (CT) image quality parameters by using different protocols and to calculate radiation dose estimates for noninvasive coronary angiography performed with dual-source CT in the step-and-shoot (SAS) mode. Materials and Methods: This study was local ethics board approved; written informed consent was obtained from all patients. In the preliminary portion of the study, 40 patients underwent CT coronary angiography in the SAS mode: at 100 kV (protocol A) in 22 patients with a body mass index (BMI) of less than 25 kg/m(2) and at 120 kV (protocol B) in 18 patients with a BMI of 25-30 kg/m(2). Both protocols involved use of an attenuation-based tube current and 1 mL of contrast material per kilogram of body weight. The final portion of the study involved 50 additional patients: 21 patients with a BMI of 25-30 kg/cm(2) assigned to protocol B and 29 patients with a BMI of less than 25 kg/cm(2) assigned to protocol C, which was performed with 100 kV, an attenuation-based tube current, and a reduced contrast material dose of 0.8 mL/kg. Image quality was independently assessed. Attenuation in the aorta and coronary arteries and image noise were measured. Radiation dose was estimated. Results: Mean image noise was similar with protocols A and B. Mean attenuation in the aorta and coronary arteries with protocol A (444 HU) was significantly (P < .001) higher than that with protocol B (358 HU). The reduced contrast material dose in protocol C yielded attenuation similar to that with protocol B. Diagnostic image quality was achieved with all protocols in 1237 (97.9%) of 1264 coronary segments. No significant differences in image quality between the 100- and 120-kV protocols were found. Mean heart rate had a significant effect on motion artifacts (area under receiver operating characteristic curve [AUC] = 0.818; 95% confidence interval [CI]: 0.723, 0.892; P < .001), whereas heart rate variability had a significant effect on stair-step artifacts (AUC = 0.79; 95% CI: 0.687, 0.865; P < .001). The mean estimated effective dose was 1.2 mSv +/- 0.2 for protocols A and C and 2.6 mSv +/- 0.5 for protocol B. Conclusion: Dual-source SAS-mode CT coronary angiography yielded diagnostic image quality for 97.9% of coronary segments at a low radiation dose. (C) RSNA, 2008.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 32 条
[1]   MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose [J].
Abada, Hicham T. ;
Larchez, Christophe ;
Daoud, Beatrice ;
Sigal-Cinqualbre, Anne ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S387-S390
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[5]   Individually adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations [J].
Das, M ;
Mahnken, AH ;
Mühlenbruch, G ;
Stargardt, A ;
Weiss, C ;
Sennst, DA ;
Flohr, TG ;
Günther, RW ;
Wildberger, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (05) :1437-1443
[6]   Use of automatic exposure control in multislice computed tomography of the coronaries:: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography [J].
Deetjen, Anja ;
Moellmann, Susanne ;
Conradi, Guido ;
Rolf, Andreas ;
Schmermund, Axel ;
Hamm, Christian W. ;
Dill, Thorsten .
HEART, 2007, 93 (09) :1040-1043
[7]   Use of high-concentration contrast media in multi pie-detector-row CT: principles and rationale [J].
Fleischmann, D .
EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) :M14-M20
[8]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[9]   Guidelines on the management of stable angina pectoris: executive summary [J].
Fox, Kim ;
Angeles Alonso Garcia, Maria ;
Ardissino, Diego ;
Buszman, Pawel ;
Katowice ;
Camici, Paolo G. ;
Crea, Filippo ;
Daly, Caroline ;
De Backer, Guy ;
Ghent ;
Hjemdahl, Paul ;
Lopez-Sendon, Jose ;
Marco, Jean ;
Morais, Joao ;
Leiria ;
Pepper, John ;
Sechtem, Udo ;
Simoons, Maarten ;
Thygesen, Kristian ;
Priori, Silvia G. ;
Blanc, Jean-Jacques ;
Budaj, Andrzej ;
Camm, John ;
Dean, Veronica ;
Deckers, Jaap ;
Dickstei, Kenneth ;
Lekakis, John ;
McGregor, Keith ;
Metra, Marco ;
Morais, Joao ;
Osterspey, Ady ;
Tamargo, Juan ;
Zamorano, Jose L. ;
Andreotti, Felicita ;
Becher, Harald ;
Dietz, Rainer ;
Fraser, Alan ;
Hernandez Antolin, Rosa Ana ;
Huber, Kurt ;
Kremastinos, Dimitris T. ;
Maseri, Attilio ;
Nesser, Hans-Joachim ;
Pasierski, Tomasz ;
Sigwart, Ulrich ;
Tubaro, Marco ;
Weis, Michael .
EUROPEAN HEART JOURNAL, 2006, 27 (11) :1341-1381
[10]   Radiation dose estimates from cardiac multislice computed tomography in daily practice -: Impact of different scanning protocols on effective dose estimates [J].
Hausleiter, J ;
Meyer, T ;
Hadamitzky, M ;
Huber, E ;
Zankl, M ;
Martinoff, S ;
Kastrati, A ;
Schömig, A .
CIRCULATION, 2006, 113 (10) :1305-1310