Technique for the calibration of hydrophones in the frequency range 10 to 600 kHz using a heterodyne interferometer and an acoustically compliant membrane

被引:28
|
作者
Theobald, PD [1 ]
Robinson, SP
Thompson, AD
Preston, RC
Lepper, PA
Wang, YB
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Univ Loughborough, Loughborough LE11 3TU, Leics, England
[3] Hangzhou Appl Acoust Res Inst, Hangzhou 311400, Zhejiang, Peoples R China
来源
关键词
D O I
10.1121/1.2063068
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A technique for the calibration of hydrophones using an optical method is presented. In the method, a measurement is made of the acoustic particle velocity in the field of a transducer by use of a thin plastic pellicle that is used to reflect the optical beam of a laser vibrometer, the pellicle being acoustically transparent at the frequency of interest. The hydrophone under test is then substituted for the pellicle, and the hydrophone response to the known acoustic field is measured. A commercially available laser vibrometer is used to undertake the calibrations, and results are presented over a frequency range from 10 to 600 kHz. A comparison is made with the method of three-transducer spherical-wave reciprocity, with agreement of better than 0.5 dB over the majority of the frequency range. The pellicle used is in the form of a narrow strip of thin Mylar (c), and a discussion is given of the effect of the properties of the pellicle on the measurement results. The initial results presented here show that the method has the potential to form the basis of a primary standard method, with the calibration traceable to standards of length measurement through the wavelength of the laser light.
引用
收藏
页码:3110 / 3116
页数:7
相关论文
共 30 条
  • [1] Primary calibration of hydrophones in the frequency range 10 to 500 kHz using a heterodyne interferometer
    Wang, Min
    Yang, Ping
    He, Longbiao
    Feng, Xiujuan
    Xing, Guangzhen
    Shengxue Xuebao/Acta Acustica, 2021, 46 (04): : 614 - 622
  • [2] Comparison of hydrophone calibration by reciprocity and heterodyne interferometer in the frequency range 500 kHz to 15 MHz
    Xing, Guangzhen
    Yang, Ping
    He, Longbiao
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 10 - 15
  • [3] A comparison of two methods for phase response calibration of hydrophones in the frequency range 10-400 kHz
    Hayman, Gary
    Wang, Yuebing
    Robinson, Stephen
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (02): : 750 - 759
  • [4] Primary calibration of membrane hydrophones in the frequency range 0.5 MHz to 60 MHz
    Preston, RC
    Robinson, SP
    Zeqiri, B
    Esward, TJ
    Gélat, PN
    Lee, ND
    METROLOGIA, 1999, 36 (04) : 331 - 343
  • [5] Primary calibration of membrane hydrophones in the frequency range 0.5 MHz to 60 MHz
    National Physical Laboratory, Teddington, Middlesex, TW11 0LW, United Kingdom
    Metrologia, 4 (331-343):
  • [6] Measurement Uncertainty in Vibration Calibration in Frequency Range of 5 Hz to 10 kHz
    Garg, Naveen
    Chauhan, B. S.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2020, 35 (03): : 397 - 405
  • [7] RF ATTENUATION CALIBRATION SYSTEM IN THE FREQUENCY RANGE OF 9 KHZ TO 10 MHZ
    Widarta, Anton
    JURNAL TEKNOLOGI, 2016, 78 (5-8): : 91 - 94
  • [8] Measurement Uncertainty in Vibration Calibration in Frequency Range of 5 Hz to 10 kHz
    Naveen Garg
    B. S. Chauhan
    MAPAN, 2020, 35 : 397 - 405
  • [9] Development of disposable membrane hydrophones for a frequency range from 1 MHz to 10 MHz
    Lee, Jae-Wan
    Ohm, Won-Suk
    Kim, Yong-Tae
    ULTRASONICS, 2017, 81 : 50 - 58
  • [10] Calibration of Miniature Medical Ultrasonic Hydrophones for Frequencies in the Range 100 to 500 kHz Using an Ultrasonically Absorbing Waveguide
    Rajagopal, Srinath
    Zeqiri, Bajram
    Gelat, Pierre N.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (05) : 765 - 778