Three-dimensional transesophageal echocardiography of the atrial septal defects

被引:7
作者
Roldan, Francisco-Javier [1 ]
Vargas-Barron, Jesus [1 ]
Vazquez-Antona, Clara [1 ]
Munoz Castellanos, Luis [2 ]
Erdmenger-Orellana, Julio [1 ]
Romero-Cardenas, Angel [1 ]
Martinez-Rios, Marco-Antonio [3 ]
机构
[1] Inst Nacl Cardiol Ignacio Chavez, Echocardiog Dept, Mexico City, DF, Mexico
[2] Inst Nacl Cardiol Ignacio Chavez, Dept Embryol, Mexico City, DF, Mexico
[3] Inst Nacl Cardiol Ignacio Chavez, Catheterizat Lab, Mexico City, DF, Mexico
关键词
D O I
10.1186/1476-7120-6-38
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.
引用
收藏
页数:7
相关论文
共 14 条
[1]   Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device - A three-dimensional transoesophageal echocardiographic reconstruction [J].
Acar, P ;
Saliba, Z ;
Bonhoeffer, P ;
Aggoun, Y ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
EUROPEAN HEART JOURNAL, 2000, 21 (07) :573-581
[2]  
Acar P, 2002, ARCH MAL COEUR VAISS, V95, P405
[3]   Three overlapping septal occlusion devices to treat residual shunting across an atrial septal defect [J].
Awaida, Jean-Pierre S. ;
Moreiras, Javier M. ;
Palacios, Igor F. .
EUROPEAN HEART JOURNAL, 2007, 28 (04) :385-385
[4]  
Graham R, 2001, Heart Lung Circ, V10, P75, DOI 10.1046/j.1444-2892.2001.00087.x
[5]   Transesophageal real-time three-dimensional echocardiography - Methods and initial in vitro and human in vivo studies [J].
Handke, Michael ;
Heinrichs, Gudrun ;
Moser, Urs ;
Hirt, Felix ;
Margadant, Felix ;
Gattiker, Felix ;
Bode, Christoph ;
Geibel, Annette .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (10) :2070-2076
[6]  
MAENO YV, 1999, CIRCULATION, V25, P99
[7]   Absent posteroinferior and anterosuperior atrial septal defect rims: Factors affecting nonsurgical closure of large secundum defects using the Amplatzer occluder [J].
Mathewson, JW ;
Bichell, D ;
Rothman, A ;
Ing, FF .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (01) :62-69
[8]   Initial experience with Live/Real time three-dimensional transesophageal echocardiography [J].
Pothineni, Koteswara R. ;
Inamdar, Vatsal ;
Andrew, P. Miller ;
Nanda, Navin C. ;
Bandarupalli, Naveen ;
Chaurasia, Preeti ;
James, K. Kirklin ;
McGiffin, David C. ;
Pajaro, Octavio E. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (10) :1099-1104
[9]   Failed Amplatzer Septal Occluder device implantation due to an embryonic septal remnant [J].
Rigatelli, Gianluca ;
Braggion, Gabriele ;
Cardaioli, Paolo ;
Faggian, Giuseppe .
EUROPEAN HEART JOURNAL, 2007, 28 (03) :309-309
[10]   Three-dimensional echocardiography of the right atrial embryonic remnants [J].
Roldán, FJ ;
Vargas-Barrón, J ;
Espinola-Zavaleta, N ;
Romero-Cárdenas, A ;
Vázquez-Antona, C .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01) :99-+