Tandem Electrochemical Desalination-Potentiometric Nitrate Sensing for Seawater Analysis

被引:45
作者
Cuartero, Maria [1 ]
Crespo, Gaston A. [1 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan & Analyt Chem, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
NANOMOLAR CONCENTRATIONS; ION CHROMATOGRAPHY; CARBON NANOTUBES; SODIUM-CHLORIDE; NATURAL-WATERS; FLOW-INJECTION; NITRITE; LAYER; CHEMILUMINESCENCE; MEMBRANES;
D O I
10.1021/acs.analchem.5b01973
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on a methodology for the direct potentiometric determination of nitrate in seawater by in-line coupling to an electrochemical desalination module. A microfluidic custom-fabricated thin layer flat cell allows one to electrochemically reduce the chloride concentration of seawater more than 100-fold, from 600 mM down to similar to 2.8 mM. The desalinator operates by the exhaustive electrochemical plating of the halides from the thin layer sample onto a silver element as silver chloride, which is coupled to the transfer of the counter cations across a permselective ion-exchange membrane to an outer solution. As a consequence of suppressing the major interference of an ion-exchanger based membrane, the 80 mu L desalinated sample plug is passed to a potentiometric flow cell of 13 mu L volume. The potentiometric sensor is composed of an all-solid-state nitrate selective electrode based on lipophilic carbon nanotubes (f-MWCNTs) as an ion-to-electron transducer (slope of -58.9 mV dec(-1), limit of detection of 5 X 10(-7) M, and response time of 5 s in batch mode) and a miniaturized reference electrode. Nitrate is successfully determined in desalinated seawater using ion chromatography as the reference method. It is anticipated that this concept may form an attractive platform for in situ environmental analysis of a variety of ions that normally suffer from interference by the high saline level of seawater.
引用
收藏
页码:8084 / 8089
页数:6
相关论文
共 24 条
[1]   Rapid flow injection analysis method for successive determination of ammonia, nitrite, and nitrate in water by gas-phase chemiluminescence [J].
Aoki, T ;
Fukuda, S ;
Hosoi, Y ;
Mukai, H .
ANALYTICA CHIMICA ACTA, 1997, 349 (1-3) :11-16
[2]  
Chen C.-T. A, 2007, OCEANOGRAPHY ENCY LI, V1, P331
[4]   Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers [J].
Crespo, Gaston A. ;
Macho, Santiago ;
Xavier Rius, F. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1316-1322
[5]   Paper-Based Thin-Layer Coulometric Sensor for Halide Determination [J].
Cuartero, Maria ;
Crespo, Gaston A. ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2015, 87 (03) :1981-1990
[6]   Exhaustive Thin-Layer Cyclic Voltammetry for Absolute Multianalyte Halide Detection [J].
Cuartero, Maria ;
Crespo, Gaston A. ;
Afshar, Majid Ghahraman ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2014, 86 (22) :11387-11395
[7]   Coulometric Sodium Chloride Removal System with Nafion Membrane for Seawater Sample Treatment [J].
Grygolowicz-Pawlak, Ewa ;
Sohail, Manzar ;
Pawlak, Marcin ;
Neel, Bastien ;
Shvarev, Alexey ;
de Marco, Roland ;
Bakker, Eric .
ANALYTICAL CHEMISTRY, 2012, 84 (14) :6158-6165
[8]   High temporal and spatial resolution environmental monitoring using flow injection with spectroscopic detection [J].
Hanrahan, G ;
Ussher, S ;
Gledhill, M ;
Achterberg, EP ;
Worsfold, PJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (04) :233-239
[9]   Methacrylate-acrylate based polymers of low plasticiser content for potassium ion-selective membranes [J].
Heng, LY ;
Hall, EAH .
ANALYTICA CHIMICA ACTA, 1996, 324 (01) :47-56
[10]   Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent [J].
Ito, Kazuaki ;
Nomura, Ryosuke ;
Fujii, Takuya ;
Tanaka, Masahito ;
Tsumura, Tomoaki ;
Shibata, Hiroyuki ;
Hirokawa, Takeshi .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (08) :2513-2517