Concomitant mitral valve procedures in patients undergoing implantation of continuous-flow left ventricular assist devices: An INTERMACS database analysis

被引:71
作者
Robertson, Jason O. [1 ]
Naftel, David C. [2 ]
Myers, Susan L. [2 ]
Tedford, Ryan J. [3 ]
Joseph, Susan M. [4 ]
Kirklin, James K. [2 ]
Silvestry, Scott C. [5 ]
机构
[1] Washington Univ, Div Cardiothorac Surg, St Louis, MO USA
[2] Univ Alabama Birmingham, Div Cardiothorac Surg, Birmingham, AL USA
[3] Johns Hopkins Sch Med, Div Cardiol, Baltimore, MD USA
[4] Baylor Univ, Med Ctr, Ctr Adv Heart & Lung Dis, Dallas, TX USA
[5] Florida Hosp Transplant Inst, Thorac Transplant Program, Orlando, FL 32804 USA
基金
美国国家卫生研究院;
关键词
left ventricular assist device; mitral regurgitation; mitral valve; mitral valve repair; mitral valve replacement; MECHANICAL CIRCULATORY SUPPORT; QUALITY-OF-LIFE; DESTINATION THERAPY; REGURGITATION; SEVERITY; DISEASE;
D O I
10.1016/j.healun.2017.09.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Management of existing mitral valve (MV) disease in patients undergoing left ventricular assist device (LVAD) implantation remains controversial. METHODS: Among continuous-flow LVAD patients with moderate to severe mitral regurgitation entered into the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database between April 2008 and March 2014 (n = 4,930), outcomes were compared between patients who underwent MV repair (MVr, n = 252), MV replacement (MVR, n = 11) and no MV procedure (no MVP, n = 4,667). Impact on survival was analyzed by stratified actuarial and hazard function multivariable methodology. Post-operative functional capacity and quality of life were assessed. RESULTS: Patients who underwent MVPs had higher pre-operative pulmonary vascular resistance (3.6 +/- 2.9 vs 2.9 +/- 2.6 Wood units; p = 0.0006) and higher pulmonary artery systolic pressures (55.1 +/- 13.8 vs 51.5 +/- 14.0 mm Hg; p = 0.0003). Two-year survival was 76% for patients with concomitant MVr, 57% for those with MVR and 71% for those with no MVP (p = 0.15). By multivariable analysis, neither MVr nor MVR affected early or late survival. Although improvements in post-operative functional status as evaluated by 6-minute walk distances were comparable across groups, visual analog score assessments of quality of life suggested a benefit of concomitant MVPs at 1-year post-implant (79.00 +/- 1.73 vs 74.45 +/- 0.51; p = 0.03), with fewer re-admissions observed for MVP patients (p < 0.0001). CONCLUSIONS: Concomitant MVPs are not associated with increased survival overall. However, MVPs are associated with benefits in terms of reduced hospital re-admission and improved quality of life in select patients. (C) 2018 Published by Elsevier Inc. on behalf of International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文
共 19 条
[1]   Effects of the HeartMate II Left Ventricular Assist Device as Observed by Serial Echocardiography [J].
Chapman, Carrie B. ;
Allana, Salman ;
Sweitzer, Nancy K. ;
Kohmoto, Takushi ;
Murray, Margaret ;
Murray, David ;
Johnson, Maryl ;
Rahko, Peter S. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (05) :513-520
[2]   Change in health-related quality of life from before to after destination therapy mechanical circulatory support is similar for older and younger patients: Analyses from INTERMACS [J].
Grady, Kathleen L. ;
Naftel, David C. ;
Myers, Susan ;
Dew, Mary Amanda ;
Weidner, Gerdi ;
Spertus, John A. ;
Idrissi, Katharine ;
Lee, Hochang B. ;
McGee, Edwin C. ;
Kirklin, James K. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (02) :213-221
[3]   Overall quality of life improves to similar levels after mechanical circulatory support regardless of severity of heart failure before implantation [J].
Grady, Kathleen L. ;
Naftel, David ;
Stevenson, Lynne ;
Dew, Mary Amanda ;
Weidner, Gerdi ;
Pagani, Francis D. ;
Kirklin, James K. ;
Myers, Susan ;
Baldwin, Timothy ;
Young, James .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2014, 33 (04) :412-421
[4]   Beyond survival: Recommendations from INTERMACS for assessing function and quality of life with mechanical circulatory support [J].
Grady, Kathleen L. ;
Stevenson, Lynne Warner ;
Pagani, Francis D. ;
Teuteberg, Jeffrey ;
Pamboukian, Salpy V. ;
Birks, Emma ;
Moore, Stephanie ;
Kirklin, James K. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (11) :1158-1164
[5]   Mitral Regurgitation and Axial Flow Left Ventricular Assist Device: A Computer Simulation Study [J].
Jelenc, Matija ;
Jelenc, Blaz ;
Vrtovec, Bojan ;
Knezevic, Ivan .
ASAIO JOURNAL, 2013, 59 (04) :405-409
[6]   Impact of concurrent surgical valve procedures in patients receiving continuous-flow devices [J].
John, Ranjit ;
Naka, Yoshifumi ;
Park, Soon J. ;
Sai-Sudhakar, Chittoor ;
Salerno, Christopher ;
Sundareswaran, Kartik S. ;
Farrar, David J. ;
Milano, Carmelo A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (02) :581-589
[7]   Significance of Residual Mitral Regurgitation After Continuous Flow Left Ventricular Assist Device Implantation [J].
Kassis, Hayah ;
Cherukuri, Krishna ;
Agarwal, Richa ;
Kanwar, Manreet ;
Elapavaluru, Subbarao ;
Sokos, George G. ;
Moraca, Robert J. ;
Bailey, Stephen H. ;
Murali, Srinivas ;
Benza, Raymond L. ;
Raina, Amresh .
JACC-HEART FAILURE, 2017, 5 (02) :81-88
[8]   Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients [J].
Kirklin, James K. ;
Naftel, David C. ;
Kormos, Robert L. ;
Stevenson, Lynne W. ;
Pagani, Francis D. ;
Miller, Marissa A. ;
Baldwin, J. Timothy ;
Young, James B. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (02) :141-156
[9]   Long-term mechanical circulatory support (destination therapy): On track to compete with heart transplantation? [J].
Kirklin, James K. ;
Naftel, David C. ;
Pagani, Francis D. ;
Kormos, Robert L. ;
Stevenson, Lynne ;
Miller, Marissa ;
Young, James B. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (03) :584-603
[10]   Pre-operative echocardiographic features associated with persistent mitral regurgitation after left ventricular assist device implantation [J].
Kitada, Shuichi ;
Kato, Tomoko S. ;
Thomas, Sunu S. ;
Conwell, Suzanne D. ;
Russo, Cesare ;
Di Tullio, Marco R. ;
Farr, Maryjane ;
Schulze, P. Christian ;
Uriel, Nir ;
Jorde, Ulrich P. ;
Takayama, Hiroo ;
Naka, Yoshifumi ;
Homma, Shunichi ;
Mancini, Donna M. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (09) :897-904