Appropriate ground motion intensity measures for estimating the earthquake demand of floor acceleration-sensitive elements in super high-rise buildings

被引:26
作者
Zhang, Yantai [1 ]
He, Zheng [1 ,2 ]
机构
[1] Dalian Univ Technol, Dept Civil Engn, Dalian, Peoples R China
[2] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian, Peoples R China
基金
国家重点研发计划;
关键词
Super high-rise building; intensity measure; demand measure; peak floor acceleration; floor acceleration response spectrum; acceleration-sensitive element; efficiency; sufficiency; SEISMIC RESPONSE; NONSTRUCTURAL COMPONENTS; SCALAR; SELECTION; DESIGN;
D O I
10.1080/15732479.2018.1544986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To characterise the functionality resilience of super high-rise buildings subjected to earthquakes, an investigation is conducted on the selection of appropriate ground motion intensity measures (IMs) for developing an efficient and sufficient correlation with peak floor acceleration (PFA) and floor acceleration response spectrum (FARS) for floor acceleration-sensitive building contents and equipment. The efficiency and sufficiency of 53 collected IMs are assessed with respect to PFA and FARS at selected floors of two example-frame core-tube super high-rise buildings. Two sets of ground motions, i.e. far-field and pulse-type near-field motions, are chosen to reflect the record-to-record variability in the investigation. The investigation indicates that with respect to PFA, the collected IMs can be divided into three different groups based on their efficiency. The ground-acceleration-related IMs, i.e. PGA (peak ground acceleration), EDA (Effective design acceleration) and A(95) (threshold of acceleration when 95% of Arias intensity is achieved), are shown to be efficient in either set of ground motions. Regarding FARS, the appropriate IMs are notably different from those in the case of PFA, from the perspective of efficiency as well as sufficiency. None of the collected IMs can maintain its sufficiency with respect to the magnitude and source-to-site distance in any case.
引用
收藏
页码:467 / 483
页数:17
相关论文
共 59 条
[1]   NGA-West2 Database [J].
Ancheta, Timothy D. ;
Darragh, Robert B. ;
Stewart, Jonathan P. ;
Seyhan, Emel ;
Silva, Walter J. ;
Chiou, Brian S. -J. ;
Wooddell, Katie E. ;
Graves, Robert W. ;
Kottke, Albert R. ;
Boore, David M. ;
Kishida, Tadahiro ;
Donahue, Jennifer L. .
EARTHQUAKE SPECTRA, 2014, 30 (03) :989-1005
[2]  
[Anonymous], 2009, FEMA P695
[3]  
[Anonymous], 1988, NP5930 EPRI
[4]  
Arias A., 1970, Seismic Design for Nuclear Power Plants, P438
[5]   Quantitative classification of near-fault ground motions using wavelet analysis [J].
Baker, Jack W. .
BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 2007, 97 (05) :1486-1501
[6]   Spectral shape proxies and nonlinear structural response [J].
Bojorquez, Eden ;
Iervolino, Iunio .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2011, 31 (07) :996-1008
[7]   Effect of building nonlinearity on seismic response of nonstructural components: A parametric study [J].
Chaudhuri, Samit Ray ;
Villaverde, Roberto .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2008, 134 (04) :661-670
[8]   SEISMIC RESPONSE OF SECONDARY SYSTEMS [J].
CHEN, YQ ;
SOONG, TT .
ENGINEERING STRUCTURES, 1988, 10 (04) :218-228
[9]  
Cordova P., 2001, Proceedings of the 2nd US-Japan workshop on performance-based earthquake engineering methodology for RC building structures, P187
[10]   A Simple and Efficient Intensity Measure to Account for Nonlinear Structural Behavior [J].
De Biasio, Marco ;
Grange, Stephane ;
Dufour, Frederic ;
Allain, Frederic ;
Petre-Lazar, Ilie .
EARTHQUAKE SPECTRA, 2014, 30 (04) :1403-1426