Gas-solids flow behavior: CFB Riser vs. Downer

被引:70
作者
Zhang, H [1 ]
Huang, WX [1 ]
Zhu, JX [1 ]
机构
[1] Univ Western Ontario, Dept Chem Engn, London, ON N6A 5B9, Canada
关键词
D O I
10.1002/aic.690470911
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Comparisons are made in a circulating fluidized-bed riser/downer system between a 15.1 in high, 0.10 m ID riser and a 9.3 in high, 0.10 in ID downer, based oil the measurements of the radial distributions of the local solids holdups and local particle velocities along the two columns. Although the core-annulus flow structures exist in both the riser and downer, the radial flow structure in the downer differs largely from that in the riser. The radial distributions of solids holdup and particle velocity ill the downer are much more uniform than those in the riser, thus ensuring the low back mixing and the nan-ow particle residence time distribution in the downer. The axial flow structure in the downer is also more uniform than that in the riser. Due to the high particle acceleration and the high particle velocity, in the downer, the overall solids holdup is significantly, lower than that in the riser. The microflow structure in the downer, characterized by, the low intermittency, indices, is also more uniform than that in the riser. These key properties of the downer make it a very promising candidate for industrial applications where short reaction times and high product selectivity, are required.
引用
收藏
页码:2000 / 2011
页数:12
相关论文
共 41 条
[1]  
BAI DR, 1991, CHEM REACT ENG TECHN, V7, P202
[2]  
BASSI AB, 1994, CIRCULATING FLUIDIZE, V4, P15
[3]   HYDRODYNAMICS OF CIRCULATING FLUIDIZED-BED RISERS - A REVIEW [J].
BERRUTI, F ;
CHAOUKI, J ;
GODFROY, L ;
PUGSLEY, TS ;
PATIENCE, GS .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1995, 73 (05) :579-602
[4]   MICROSTRUCTURAL ASPECTS OF THE BEHAVIOR OF CIRCULATING FLUIDIZED-BEDS [J].
BRERETON, CMH ;
GRACE, JR .
CHEMICAL ENGINEERING SCIENCE, 1993, 48 (14) :2565-2572
[5]  
CAO C, 1998, ADV TECHN PART PROC, P38
[6]   HYDRODYNAMIC CHARACTERISTICS OF INVERSE FLUIDIZATION IN LIQUID SOLID AND GAS-LIQUID SOLID SYSTEMS [J].
FAN, LS ;
MUROYAMA, K ;
CHERN, SH .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1982, 24 (02) :143-150
[7]   Situating the high-density circulating fluidized bed [J].
Grace, JR ;
Issangya, AS ;
Bai, DR ;
Bi, HT ;
Zhu, JX .
AICHE JOURNAL, 1999, 45 (10) :2108-2116
[8]   HIGH-VELOCITY FLUIDIZED-BED REACTORS [J].
GRACE, JR .
CHEMICAL ENGINEERING SCIENCE, 1990, 45 (08) :1953-1966
[9]  
Hartge E.-U., 1988, P 2 INT C CIRC FLUID, P165, DOI [10.1016/b978-0-08-036225-0.50020-4, DOI 10.1016/B978-0-08-036225-0.50020-4]
[10]  
HARTGE EU, 1986, FLUIDIZATION, V5, P165