Shortening delivery times for intensity-modulated proton therapy by reducing the number of proton spots: an experimental verification

被引:29
作者
van de Water, Steven [1 ]
Belosi, Maria F. [1 ]
Albertini, Francesca [1 ]
Winterhalter, Carla [1 ,2 ]
Weber, Damien C. [1 ,3 ,4 ]
Lomax, Antony J. [1 ,2 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
[4] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
基金
欧盟地平线“2020”;
关键词
proton therapy; IMPT; pencil beam scanning; delivery time reduction; spot reduction; treatment efficiency; QUALITY-ASSURANCE; OPTIMIZATION; ROBUSTNESS; EFFICIENCY; REDUCTION; POINT; COST; PLAN;
D O I
10.1088/1361-6560/ab7e7c
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Delivery times of intensity-modulated proton therapy (IMPT) can be shortened by reducing the number of spots in the treatment plan, but this may affect clinical plan delivery. Here, we assess the experimental deliverability, accuracy and time reduction of spot-reduced treatment planning for a clinical case, as well as its robustness. For a single head-and-neck cancer patient, a spot-reduced plan was generated and compared with the conventional clinical plan. The number of proton spots was reduced using the iterative 'pencil beam resampling' technique. This involves repeated inverse optimization, while adding in each iteration a small sample of randomly selected spots and subsequently excluding low-weighted spots until plan quality deteriorates. Field setup was identical for both plans and comparable dosimetric quality was a prerequisite. Both IMPT plans were delivered on PSI Gantry 2 and measured in water, while delivery log-files were used to extract delivery times and reconstruct the delivered dose via Monte-Carlo dose calculations. In addition, robustness simulations were performed to assess sensitivity to machine inaccuracies and errors in patient setup and proton range. The number of spots was reduced by 96% (from 33 855 to 1510 in total) without compromising plan quality. The spot-reduced plan was deliverable on our gantry in standard clinical mode and resulted in average delivery times per field being shortened by 46% (from 51.2 to 27.6 s). For both plans, differences between measured and calculated dose were within clinical tolerance for patient-specific verifications and Monte-Carlo dose reconstructions were in accordance with clinical experience. The spot-reduced plan was slightly more sensitive to machine inaccuracies, but more robust against setup and range errors. In conclusion, for an example head-and-neck case, spot-reduced IMPT planning provided a deliverable treatment plan and enabled considerable shortening of the delivery time (similar to 50%) without compromising plan quality or delivery accuracy, and without substantially affecting robustness.
引用
收藏
页数:14
相关论文
共 38 条
[1]   Is it necessary to plan with safety margins for actively scanned proton therapy? [J].
Albertini, F. ;
Hug, E. B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4399-4413
[2]   The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans [J].
Albertini, F. ;
Hug, E. B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10) :2863-2878
[3]  
Albertini Francesca., 2009, Biomedical Mathematics: Promising Directions in Imaging, Therapy Planning, and Inverse Problems, V1, P1
[4]   An interior-point implementation developed and tuned for radiation therapy treatment planning [J].
Breedveld, Sebastiaan ;
van den Berg, Bas ;
Heijmen, Ben .
COMPUTATIONAL OPTIMIZATION AND APPLICATIONS, 2017, 68 (02) :209-242
[5]   iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans [J].
Breedveld, Sebastiaan ;
Storchi, Pascal R. M. ;
Voet, Peter W. J. ;
Heijmen, Ben J. M. .
MEDICAL PHYSICS, 2012, 39 (02) :951-963
[6]   Proton energy optimization and reduction for intensity-modulated proton therapy [J].
Cao, Wenhua ;
Lim, Gino ;
Liao, Li ;
Li, Yupeng ;
Jiang, Shengpeng ;
Li, Xiaoqiang ;
Li, Heng ;
Suzuki, Kazumichi ;
Zhu, X. Ronald ;
Gomez, Daniel ;
Zhang, Xiaodong .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21) :6341-6354
[7]   Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice [J].
Favaudon, Vincent ;
Caplier, Laura ;
Monceau, Virginie ;
Pouzoulet, Frederic ;
Sayarath, Mano ;
Fouillade, Charles ;
Poupon, Marie-France ;
Brito, Isabel ;
Hupe, Philippe ;
Bourhis, Jean ;
Hall, Janet ;
Fontaine, Jean-Jacques ;
Vozenin, Marie-Catherine .
SCIENCE TRANSLATIONAL MEDICINE, 2014, 6 (245)
[8]   Feasibility of Pencil Beam Scanned Intensity Modulated Proton Therapy in Breath-hold for Locally Advanced Non-Small Cell Lung Cancer [J].
Gorgisyan, Jenny ;
af Rosenschold, Per Munck ;
Perrin, Rosalind ;
Persson, Gitte F. ;
Josipovic, Mirjana ;
Belosi, Maria Francesca ;
Engelholm, Svend Aage ;
Weber, Damien C. ;
Lomax, Antony J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (05) :1121-1128
[9]   VARIATIONS IN LINEAR ENERGY TRANSFER WITHIN CLINICAL PROTON THERAPY FIELDS AND THE POTENTIAL FOR BIOLOGICAL TREATMENT PLANNING [J].
Grassberger, Clemens ;
Trofimov, Alexei ;
Lomax, Anthony ;
Paganetti, Harald .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05) :1559-1566
[10]   Non-uniform depth scanning for proton therapy systems employing active energy variation [J].
Kang, Joanne H. ;
Wilkens, Jan J. ;
Oelfke, Uwe .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :N149-N155