Respiratory Gating Techniques for Optimization of Lung Cancer Radiotherapy

被引:103
作者
Giraud, Philippe [1 ,2 ]
Morvan, Esra [2 ]
Claude, Line [3 ]
Mornex, Francoise [4 ]
Le Pechoux, Cecile [5 ]
Bachaud, Jean-Marc [6 ]
Boisselier, Pierre [7 ]
Beckendorf, Veronique [8 ]
Morelle, Magali [9 ]
Carrere, Marie-Odile [9 ]
机构
[1] Paris Descartes Univ, Serv Oncol Radiotherapie, Hop Europeen Georges Pompidou, Dept Radiat Oncol, F-75015 Paris, France
[2] Inst Curie, Dept Radiat Oncol, Paris, France
[3] Ctr Leon Berard, Dept Radiat Oncol, F-69373 Lyon, France
[4] Hosp Civils Lyon, Dept Radiat Oncol, Lyon, France
[5] Inst Gustave Roussy, Dept Radiat Oncol, Villejuif, France
[6] Inst Claudius Regaud, Dept Radiat Oncol, Toulouse, France
[7] Ctr Val Aurelle, Dept Radiat Oncol, Montpellier, France
[8] Ctr Alexis Vautrin, Dept Radiat Oncol, Nancy, France
[9] Ctr Leon Berard, GATE UMR CNRS 5824, F-69373 Lyon, France
关键词
Non-small cell lung cancer; Respiratory gating; Breath-hold techniques; Toxicities; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; INSPIRATION BREATH-HOLD; RADIATION-THERAPY; GATED RADIOTHERAPY; TUMOR MOTION; ORGAN MOTION; MANAGEMENT; DELIVERY; MARGIN; BEAM;
D O I
10.1097/JTO.0b013e3182307ec2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The primary objective of the STIC 2003 project was to compare the clinical and economic aspects of respiratory-gated conformal radiotherapy (RGRT), an innovative technique proposed to limit the impact of respiratory movements during irradiation, versus conventional conformal radiotherapy, the reference radiation therapy for lung cancer. Methods and Materials: A comparative, nonrandomized, multicenter, and prospective cost toxicity analysis was performed in the context of this project between April 2004 and June 2008 in 20 French centers. Only the results of the clinical study are presented here, as the results of the economic assessment have been published previously. Results: The final results based on 401 evaluable patients confirm the feasibility and good reproducibility of the various RGRT systems. The results of this study demonstrated a marked reduction of dosimetric parameters predictive of pulmonary, cardiac and esophageal toxicity as a result of the various respiratory gating techniques. These dosimetric benefits were mainly observed with deep inspiration breath-hold (DIBH) techniques (ABC and SDX systems), which markedly increased the total lung volume compared with the inspiration-synchronized system based on tidal volume (Real-time Position Management). These theoretical dosimetric benefits were correlated clinically with a significant reduction of pulmonary acute toxicity, and the pulmonary, cardiac, and esophageal late toxicities, especially with DIBH techniques. Pulmonary function parameters, although more heterogeneous, especially DLCO, showed a tendency to reduction of pulmonary toxicity in the RGRT group. Conclusions: RGRT seems to be essential to reduce toxicities, especially the pulmonary, cardiac, and esophageal late toxicities with the DIBH methods.
引用
收藏
页码:2058 / 2068
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 1995, RADIOTHER ONCOL, V35, P17
[2]  
[Anonymous], R LANG ENV STAT COMP
[3]   Clinical experience using respiratory gated radiation therapy: Comparison of free-breathing and breath-hold techniques [J].
Berson, AM ;
Emery, R ;
Rodriguez, L ;
Richards, GM ;
Ng, T ;
Sanghavi, S ;
Barsa, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02) :419-426
[4]   Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients [J].
Chen, QS ;
Weinhous, MS ;
Deibel, FC ;
Ciezki, JP ;
Macklis, RM .
MEDICAL PHYSICS, 2001, 28 (09) :1850-1856
[5]   TOXICITY CRITERIA OF THE RADIATION-THERAPY ONCOLOGY GROUP (RTOG) AND THE EUROPEAN-ORGANIZATION-FOR-RESEARCH-AND-TREATMENT-OF-CANCER (EORTC) [J].
COX, JD ;
STETZ, J ;
PAJAK, TF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (05) :1341-1346
[6]   Dosimetric effect of respiration-gated beam on IMRT delivery [J].
Duan, J ;
Shen, S ;
Fiveash, JB ;
Brezovich, IA ;
Popple, RA ;
Pareek, PN .
MEDICAL PHYSICS, 2003, 30 (08) :2241-2252
[7]   The effect of breathing and set-up errors on the cumulative dose to a lung tumor [J].
Engelsmann, M ;
Damen, EMF ;
De Jaeger, K ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :95-105
[8]  
Giraud P, 2006, Cancer Radiother, V10, P269, DOI 10.1016/j.canrad.2006.05.009
[9]   Evaluation of microscopic tumor extension in non-small-cell lung cancer for three-dimensional conformal radiotherapy planning [J].
Giraud, P ;
Antoine, M ;
Larrouy, A ;
Milleron, B ;
Callard, P ;
De Rycke, Y ;
Carette, MF ;
Rosenwald, JC ;
Cosset, JM ;
Housset, M ;
Touboul, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04) :1015-1024
[10]   Conformal radiotherapy (CRT) planning for lung cancer: Analysis of intrathoracic organ motion during extreme phases of breathing [J].
Giraud, P ;
De Rycke, Y ;
Dubray, B ;
Helfre, S ;
Voican, D ;
Guo, L ;
Rosenwald, JC ;
Keraudy, K ;
Housset, M ;
Touboul, E ;
Cosset, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :1081-1092