Quantitative detection of Legionella pneumophila in water samples by Immunomagnetic purification and real-time PCR amplification of the dotA gene

被引:91
作者
Yáñez, MA [1 ]
Carrasco-Serrano, C [1 ]
Barberá, VM [1 ]
Catalán, V [1 ]
机构
[1] Labaqua, Pol Ind Atalayas, Alicante 03114, Spain
关键词
D O I
10.1128/AEM.71.7.3433-3441.2005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.
引用
收藏
页码:3433 / 3441
页数:9
相关论文
共 46 条
[21]   Population genetic structure of Legionella pneumophila inferred from RNA polymerase gene (rpoB) and DotA gene (dotA) sequences [J].
Ko, KS ;
Lee, HK ;
Park, MY ;
Park, MS ;
Lee, KH ;
Woo, SY ;
Yun, YJ ;
Kook, YH .
JOURNAL OF BACTERIOLOGY, 2002, 184 (08) :2123-2130
[22]  
KOK JB, 2002, HUM MUTAT, V19, P554
[23]   Inclusion of polyvinylpyrrolidone in the polymerase chain reaction reverses the inhibitory effects of polyphenolic contamination of RNA [J].
Koonjul, PK ;
Brandt, WF ;
Farrant, JM ;
Lindsey, GG .
NUCLEIC ACIDS RESEARCH, 1999, 27 (03) :915-916
[24]  
Kuhne B.S, 2003, BIOCHEMICA, V3, P9
[25]   GROWTH OF 28 LEGIONELLA SPECIES ON SELECTIVE CULTURE MEDIA - A COMPARATIVE-STUDY [J].
LEE, TLC ;
VICKERS, RM ;
YU, VL ;
WAGENER, MM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (10) :2764-2768
[26]   Rapid detection of Mycobacterium avium in stool samples from AIDS patients by immunomagnetic PCR [J].
Li, ZM ;
Bai, GH ;
vonReyn, CF ;
Marino, P ;
Brennan, MJ ;
Gine, N ;
Morris, SL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (08) :1903-1907
[27]   Detection and speciation of Cryptosporidium spp. in environmental water samples by immunomagnetic separation, PCR and endonuclease restriction [J].
Lowery, CJ ;
Moore, JE ;
Millar, BC ;
Burke, DP ;
McCorry, KAJ ;
Crothers, E ;
Dooley, JSG .
JOURNAL OF MEDICAL MICROBIOLOGY, 2000, 49 (09) :779-785
[28]  
Madden TL, 1996, METHOD ENZYMOL, V266, P131
[29]  
Maniatis T.A., 1982, MOL CLONING
[30]   RAPID DIAGNOSIS OF ENTEROVIRUS INFECTION BY MAGNETIC BEAD EXTRACTION AND POLYMERASE CHAIN-REACTION DETECTION OF ENTEROVIRUS RNA IN CLINICAL SPECIMENS [J].
MUIR, P ;
NICHOLSON, F ;
JHETAM, M ;
NEOGI, S ;
BANATVALA, JE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (01) :31-38